{"id":2833,"date":"2026-03-26T00:00:00","date_gmt":"2026-03-26T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/qsfp28-msa-explained-compatibility-standards-risks\/"},"modified":"2026-06-22T03:46:26","modified_gmt":"2026-06-22T03:46:26","slug":"qsfp28-msa-explained-compatibility-standards-risks","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/qsfp28-msa-explained-compatibility-standards-risks","title":{"rendered":"QSFP28 MSA explicado: Compatibilidad, normas y riesgos"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/28368bcfa4a34a62b9c73e0e991aa66d.jpg\" alt=\"QSFP28 MSA Explained: Compatibility, Standards, and Risks\" class=\"wp-image-2824\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/28368bcfa4a34a62b9c73e0e991aa66d.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/28368bcfa4a34a62b9c73e0e991aa66d-300x157.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/28368bcfa4a34a62b9c73e0e991aa66d-1024x536.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/28368bcfa4a34a62b9c73e0e991aa66d-768x402.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/28368bcfa4a34a62b9c73e0e991aa66d-18x9.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">En centros de datos modernos y redes empresariales de alta velocidad, la conectividad de 100 G se ha convertido en el nuevo est\u00e1ndar b\u00e1sico. Entre las soluciones m\u00e1s ampliamente adoptadas se encuentra la <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\">transceptor QSFP28<\/a>, un factor de forma compacto dise\u00f1ado para ofrecer un rendimiento de 100 Gbps mediante cuatro canales paralelos de 25 G. En el centro de su adopci\u00f3n generalizada se encuentra el concepto de QSFP28 MSA (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/multi-source-agreements-optical-transceivers\/\">Acuerdo Multifabricante<\/a>)\u2014un est\u00e1ndar destinado a garantizar la interoperabilidad entre m\u00faltiples proveedores.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pero aqu\u00ed radica la realidad cr\u00edtica:<br\/>aunque QSFP28 MSA define dimensiones mec\u00e1nicas, interfaces el\u00e9ctricas y el comportamiento \u00f3ptico b\u00e1sico, no garantiza una compatibilidad perfecta en implementaciones reales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esta brecha entre <em>estandarizaci\u00f3n<\/em> and <em>y rendimiento real<\/em> es precisamente por lo que muchos ingenieros de redes buscan t\u00e9rminos como:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><em>\u00bfQu\u00e9 es un SFP compatible con MSA?<\/em><\/p><\/li><li><p><em>\u00bfQu\u00e9 significa realmente \u00abcompatible con MSA\u00bb?<\/em><\/p><\/li><li><p><em>\u00bfPor qu\u00e9 fallan los m\u00f3dulos QSFP28 incluso si cumplen con MSA?<\/em><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">En la pr\u00e1ctica, los usuarios suelen encontrarse con problemas inesperados tales como:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>m\u00f3dulos no reconocidos por los switches<\/p><\/li><li><p>fallos de enlace debidos a firmware o <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a> incompatibilidades<\/p><\/li><li><p>inestabilidad del rendimiento pese a la \u201cconformidad con MSA\u201d<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Estos desaf\u00edos resaltan una verdad importante: QSFP28 MSA garantiza una base com\u00fan, pero una implementaci\u00f3n exitosa depende de mucho m\u00e1s que del est\u00e1ndar en s\u00ed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Qu\u00e9 aprender\u00e1 en esta gu\u00eda<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Al leer este art\u00edculo, obtendr\u00e1 una comprensi\u00f3n clara y pr\u00e1ctica de:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>The <strong>el significado real de QSFP28 MSA<\/strong> y qu\u00e9 es exactamente lo que estandariza<\/p><\/li><li><p>La diferencia entre <strong>conformidad con MSA y compatibilidad real<\/strong><\/p><\/li><li><p>C\u00f3mo se compara QSFP28 con SFP y otros tipos de transceptores<\/p><\/li><li><p>Si QSFP28 admite <strong>fibra monomodo o multimodo<\/strong><\/p><\/li><li><p>The <strong>los escenarios de fallo m\u00e1s comunes en entornos reales<\/strong> (basados en experiencias de usuarios)<\/p><\/li><li><p>A <strong>una lista de verificaci\u00f3n paso a paso<\/strong> para garantizar una implementaci\u00f3n fiable de QSFP28<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ya sea que est\u00e9 planeando una nueva red de 100 G, solucionando problemas de interoperabilidad o adquiriendo m\u00f3dulos \u00f3pticos confiables, esta gu\u00eda le ayudar\u00e1 a tomar decisiones informadas y de bajo riesgo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Comencemos desglosando los fundamentos: \u00bfqu\u00e9 es exactamente QSFP28 MSA y por qu\u00e9 importa?<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 \u00bfQu\u00e9 es QSFP28 MSA y por qu\u00e9 importa<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c282be35616a46b38ec787a76018f748.jpg\" alt=\"What Is QSFP28 MSA and Why It Matters\" class=\"wp-image-2825\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c282be35616a46b38ec787a76018f748.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c282be35616a46b38ec787a76018f748-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c282be35616a46b38ec787a76018f748-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c282be35616a46b38ec787a76018f748-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c282be35616a46b38ec787a76018f748-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 significa QSFP28?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP28 (Forma de factor peque\u00f1o cu\u00e1druple 28) es una tecnolog\u00eda de alta velocidad <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/488422.htm\">transceptor \u00f3ptico<\/a> est\u00e1ndar dise\u00f1ada para aplicaciones de Ethernet de 100 Gigabits (100G). Logra esto mediante el uso de:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>4 canales independientes, cada uno operando a 25 Gbps<\/strong><\/p><\/li><li><p><strong>Ancho de banda agregado total de 100 Gbps<\/strong><\/p><\/li><li><p>Formato compacto y extra\u00edble en caliente para conmutadores y routers<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472126.htm\">Los m\u00f3dulos QSFP28<\/a> se utilizan ampliamente en:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Centros de datos (arquitectura espina-hoja)<\/p><\/li><li><p>Infraestructura en la nube<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/optical-modules-high-performance-computing-applications\/\">Computaci\u00f3n de alto rendimiento<\/a> (HPC)<\/p><\/li><li><p>Redes corporativas centrales<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 es el MSA (Acuerdo Multifabricante)?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El MSA (Acuerdo Multifabricante) es una especificaci\u00f3n impulsada por la industria, desarrollada por m\u00faltiples fabricantes para estandarizar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Dimensiones f\u00edsicas<\/strong> (tama\u00f1o, tipo de conector)<\/p><\/li><li><p><strong>Interfaz el\u00e9ctrica<\/strong> (estructura de canales, se\u00f1alizaci\u00f3n)<\/p><\/li><li><p><strong>Interfaz de gesti\u00f3n<\/strong> (comunicaci\u00f3n I\u00b2C, diagn\u00f3sticos)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para QSFP28, el MSA garantiza que los m\u00f3dulos de distintos proveedores puedan:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Encajar en el mismo puerto QSFP28<br\/>\u2705 Seguir la misma estructura de se\u00f1alizaci\u00f3n el\u00e9ctrica<br\/>\u2705 Proporcionar diagn\u00f3sticos digitales estandarizados (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/troubleshoot-optical-transceivers-digital-diagnostic-monitoring\/\">DDM<\/a>)<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Importante: Lo que S\u00cd hace el MSA de QSFP28 <em>NO<\/em> Garantiza<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Aqu\u00ed es donde comienza la mayor parte de la confusi\u00f3n \u2014y de los problemas reales\u2014.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aunque el MSA de QSFP28 define la base, NO estandariza:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u274c El comportamiento del firmware del fabricante<\/p><\/li><li><p>\u274c La codificaci\u00f3n de la EEPROM (reconocimiento del ID del fabricante)<\/p><\/li><li><p>\u274c La compatibilidad de la correcci\u00f3n de errores hacia adelante (FEC)<\/p><\/li><li><p>\u274c La interoperabilidad a nivel del sistema operativo del conmutador o del ASIC<\/p><\/li><li><p>\u274c La calidad o fiabilidad del producto<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Esto explica un problema com\u00fan en entornos reales: incluso si dos m\u00f3dulos QSFP28 son \u201ccompatibles con el MSA\u201d, pueden no funcionar correctamente en el mismo conmutador.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Por qu\u00e9 el MSA de QSFP28 es relevante en implementaciones reales<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Comprender el MSA de QSFP28 es fundamental porque afecta directamente a:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >Flexibilidad en la adquisici\u00f3n de m\u00faltiples fabricantes<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Permite a los equipos de compras evitar la dependencia exclusiva de un \u00fanico fabricante<\/p><\/li><li><p>Apoya la optimizaci\u00f3n de costos mediante \u00f3pticas de terceros<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >Escalabilidad en el dise\u00f1o de redes<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Garantiza una forma de factor consistente en toda la infraestructura de 100G<\/p><\/li><li><p>Simplifica las actualizaciones de 40G (<a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">QSFP+<\/a>) a 100G (<a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482496.htm\">QSFP28<\/a>)<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >Conciencia de riesgos en cuanto a compatibilidad<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Ayuda a los ingenieros a reconocer que: <em>\u201cCompatible con el MSA\u201d NO significa listo para usar<\/em><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >La \u201cbrecha de la ilusi\u00f3n MSA\u201d (idea clave)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un concepto cr\u00edtico para ingenieros y compradores:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 344px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"344\"><p>Expectativa<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Realidad<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"344\"><p>MSA = compatibilidad completa<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MSA = solo f\u00edsico + nivel b\u00e1sico<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"344\"><p>Todos los m\u00f3dulos QSFP28 son interoperables<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Todav\u00eda se requiere ajuste por parte del fabricante<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"344\"><p>El est\u00e1ndar garantiza la estabilidad<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>La calidad de la implementaci\u00f3n determina la estabilidad<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Conclusi\u00f3n final<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28<\/strong> define el factor de forma de 100G y la arquitectura de canales<\/p><\/li><li><p><strong>y MSA<\/strong> define el est\u00e1ndar industrial compartido para ese factor de forma<\/p><\/li><li><p>Pero el \u00e9xito en el mundo real depende de:<\/p><ul><li><p>Compatibilidad con el fabricante<\/p><\/li><li><p>Alineaci\u00f3n del firmware<\/p><\/li><li><p>Buenas pr\u00e1cticas de implementaci\u00f3n<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n, profundizaremos en una pregunta cr\u00edtica que muchos usuarios plantean: \u00bfQu\u00e9 significa realmente \u201ccompatible con MSA\u201d \u2014y por qu\u00e9 suele causar confusi\u00f3n?<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 \u00bfQu\u00e9 significa realmente \u201ccompatible con MSA\u201d?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cCompatible con MSA\u201d significa que un transceptor cumple con las especificaciones compartidas de hardware e interfaz definidas por el Acuerdo Multifabricante (MSA).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En t\u00e9rminos sencillos, un m\u00f3dulo QSFP28 compatible con MSA:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>se inserta en cualquier puerto QSFP28<\/p><\/li><li><p>utiliza la misma estructura el\u00e9ctrica de canales (4\u00d725G)<\/p><\/li><li><p>admite diagn\u00f3sticos digitales est\u00e1ndar (DDM\/DOM)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pero aqu\u00ed radica el punto clave: la compatibilidad con MSA garantiza la interoperabilidad f\u00edsica, no la compatibilidad operativa<strong>.<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0e21d2a242ae441d8c9556f610d3f977.jpg\" alt=\"What Does \u201cMSA Compatible\u201d Really Mean?\" class=\"wp-image-2826\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0e21d2a242ae441d8c9556f610d3f977.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0e21d2a242ae441d8c9556f610d3f977-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0e21d2a242ae441d8c9556f610d3f977-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0e21d2a242ae441d8c9556f610d3f977-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0e21d2a242ae441d8c9556f610d3f977-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Compatible con MSA frente a compatible con el fabricante (diferencia cr\u00edtica)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Esta distinci\u00f3n es la fuente de la mayor\u00eda de los problemas de implementaci\u00f3n.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 223px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"223\"><p>Type<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Qu\u00e9 significa<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Impacto en el mundo real<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"223\"><p><strong>Compatible con MSA<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Cumple con la especificaci\u00f3n industrial de hardware<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Se ajustar\u00e1 f\u00edsicamente y se encender\u00e1<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"223\"><p><strong>Compatible con el fabricante<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Programado y probado para una marca espec\u00edfica de conmutador<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Funcionar\u00e1 de forma fiable<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ejemplo:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Un m\u00f3dulo gen\u00e9rico <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/488423.htm\">m\u00f3dulo QSFP28<\/a> puede ser compatible con MSA<\/p><\/li><li><p>Pero sin una codificaci\u00f3n adecuada de la EEPROM, podr\u00eda:<\/p><ul><li><p>no ser reconocido por el conmutador<\/p><\/li><li><p>activar advertencias de compatibilidad<\/p><\/li><li><p>deshabilitar por completo el puerto<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Por qu\u00e9 \u201ccompatible con MSA\u201d suele causar confusi\u00f3n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Muchos fabricantes usan \u201ccompatible con MSA\u201d en su marketing para sugerir:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\u201cFunciona con todos los dispositivos\u201d<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">En realidad, seg\u00fan el comportamiento industrial y los comentarios de los usuarios:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>algunos conmutadores aplican bloqueo por fabricante (listas blancas)<\/p><\/li><li><p>otros requieren:<\/p><ul><li><p>versiones espec\u00edficas de firmware<\/p><\/li><li><p>configuraciones coincidentes de FEC<\/p><\/li><\/ul><\/li><li><p>Incluso cuando los enlaces se establecen:<\/p><ul><li><p>la estabilidad no est\u00e1 garantizada<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Esto lleva al concepto err\u00f3neo com\u00fan: MSA = conecte y use (lo cual NO es cierto).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >La capa oculta: EEPROM y firmware<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Detr\u00e1s de cada m\u00f3dulo QSFP28 hay un peque\u00f1o chip de memoria (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/eeprom-electrically-erasable-programmable-read-only-memory\/\">EEPROM<\/a>Velocidades de datos compatibles<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>nombre del fabricante<\/p><\/li><li><p>N\u00famero de pieza<\/p><\/li><li><p>identificadores de compatibilidad<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Los conmutadores leen estos datos durante la inicializaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si el m\u00f3dulo no est\u00e1 codificado correctamente:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>el conmutador podr\u00eda rechazarlo<\/p><\/li><li><p>o funcionar en modo degradado<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Por esta raz\u00f3n, dos m\u00f3dulos f\u00edsicamente id\u00e9nticos pueden comportarse de forma completamente distinta.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Escenarios del mundo real (basados en la experiencia del usuario)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los ingenieros informan con frecuencia:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u274c Errores de \u201cm\u00f3dulo no compatible\u201d<\/p><\/li><li><p>\u274c Fallo en el establecimiento del enlace a pesar de un cableado correcto<\/p><\/li><li><p>\u274c Parpadeo aleatorio del enlace bajo carga<\/p><\/li><li><p>\u274c Reducci\u00f3n autom\u00e1tica de velocidad (100G \u2192 40G o inferior)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Causas fundamentales comunes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Incoherencia del EEPROM<\/p><\/li><li><p>Incompatibilidad de firmware<\/p><\/li><li><p>Desalineaci\u00f3n de FEC<\/p><\/li><li><p>Mala calidad \u00f3ptica (especialmente en m\u00f3dulos de bajo costo)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1ndo funciona realmente bien la compatibilidad MSA?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los m\u00f3dulos QSFP28 compatibles con MSA tienden a funcionar de forma fiable cuando:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u2714 Los switches son de plataforma abierta (sin bloqueo de proveedor)<\/p><\/li><li><p>\u2714 Los m\u00f3dulos est\u00e1n preconfigurados para la marca objetivo<\/p><\/li><li><p>\u2714 Las versiones de firmware est\u00e1n sincronizadas<\/p><\/li><li><p>\u2714 Se realizan pruebas adecuadas antes de la implementaci\u00f3n<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Conclusi\u00f3n pr\u00e1ctica<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Compatible con MSA = normalizaci\u00f3n a nivel de hardware<\/p><\/li><li><p>Compatibilidad con el proveedor = usabilidad en entornos reales<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Trate siempre la etiqueta \u201ccompatible con MSA\u201d como un punto de partida, no como una garant\u00eda<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Antes de comprar o implementar <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491586.htm\">QSFP28 de 100 G<\/a> m\u00f3dulos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Verifique la compatibilidad con su modelo espec\u00edfico de switch<\/p><\/li><li><p>Solicite soporte de codificaci\u00f3n del proveedor si utiliza componentes \u00f3pticos de terceros<\/p><\/li><li><p>Pruebe los m\u00f3dulos en un entorno de laboratorio<\/p><\/li><li><p>Evite asumir la interoperabilidad entre distintos proveedores<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n, aclaremos otra pregunta com\u00fan en el dise\u00f1o de redes: \u00bfcu\u00e1l es la diferencia entre QSFP28 y SFP, y cu\u00e1ndo debe usar cada uno?<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 QSFP28 frente a SFP: diferencias clave explicadas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Al dise\u00f1ar o actualizar una red, una de las preguntas m\u00e1s comunes es: \u00bfcu\u00e1l es la diferencia entre SFP y QSFP28, y cu\u00e1l deber\u00eda usar?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aunque ambos son <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491548.htm\">transceptores extra\u00edbles<\/a>, desempe\u00f1an funciones muy distintas en la arquitectura moderna de redes.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33d2bb2298244efe84275d24ca7ed165.jpg\" alt=\"QSFP28 vs. SFP: Key Differences\" class=\"wp-image-2827\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33d2bb2298244efe84275d24ca7ed165.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33d2bb2298244efe84275d24ca7ed165-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33d2bb2298244efe84275d24ca7ed165-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33d2bb2298244efe84275d24ca7ed165-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33d2bb2298244efe84275d24ca7ed165-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Diferencias t\u00e9cnicas fundamentales<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 205px;\"\/><col style=\"width: 244px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"205\"><p>Caracter\u00edstica<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"244\"><p>SFP \/ SFP+ \/ SFP28<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>QSFP28<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"205\"><p>Nombre completo<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"244\"><p>SFF-8472<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Quad Small Form-factor Pluggable 28<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"205\"><p>Estructura de canales<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"244\"><p>1 canal<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 v\u00edas<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"205\"><p>Velocidad t\u00edpica<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"244\"><p>1 G \/ 10 G \/ 25 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G (4 \u00d7 25G)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"205\"><p>Tipo de conector<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"244\"><p><a target=\"_self\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/sfp-duplex-lc-connector-explained\/\">LC<\/a> (fibra d\u00faplex)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/understanding-polarity-in-mtp-mpo-system-for-signal-integrity\/\">MPO\/MTP<\/a> (fibra m\u00faltiple)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"205\"><p>Densidad de puertos<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"244\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mayor (4\u00d7 ancho de banda por puerto)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"205\"><p>Consumo de energ\u00eda<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"244\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Superior<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"205\"><p>Caso de uso t\u00edpico<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"244\"><p>Acceso \/ borde<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Espina dorsal \/ n\u00facleo \/ agregaci\u00f3n<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Diferencia arquitect\u00f3nica: canal \u00fanico frente a m\u00faltiples canales<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La distinci\u00f3n t\u00e9cnica m\u00e1s importante radica en c\u00f3mo se transmite la informaci\u00f3n:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\"><strong>SFP<\/strong><\/a><strong> <\/strong>(incluyendo <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">SFP28<\/a>) utiliza:<\/p><ul><li><p><strong>1 canal<\/strong> (hasta 25 Gbps)<\/p><\/li><\/ul><\/li><li><p><strong>QSFP28<\/strong> utiliza:<\/p><ul><li><p><strong>4 canales paralelos<\/strong>, cada uno de 25 Gbps<\/p><\/li><li><p>Combinados en 100 Gbps<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Este dise\u00f1o de m\u00faltiples canales es lo que permite al QSFP28 ofrecer un alto ancho de banda en un factor de forma compacto.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Diferencias en los casos de uso (d\u00f3nde se aplica cada uno)<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >SFP \/ SFP28 \u2014 Capa de acceso<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Ideal para:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Conexiones de servidor<\/p><\/li><li><p>Redes perimetrales empresariales<\/p><\/li><li><p>Enlaces de corta distancia<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Escenarios t\u00edpicos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Enlaces ascendentes de servidores de 10 G o 25 G<\/p><\/li><li><p>Conmutadores de acceso a agregaci\u00f3n<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >QSFP28 \u2014 N\u00facleo y espina de centros de datos<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Ideal para:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Enlaces troncales de alta capacidad<\/p><\/li><li><p>Interconexiones de centro de datos<\/p><\/li><li><p>Infraestructura a escala de nube<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Escenarios t\u00edpicos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Conexiones entre espina y hoja<\/p><\/li><li><p>Enlaces de 100 G entre conmutadores<\/p><\/li><li><p>Clusters de computaci\u00f3n de alto rendimiento<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Capacidad de divisi\u00f3n (ventaja importante)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Una ventaja principal de QSFP28: puede dividirse en varios enlaces de menor velocidad<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Por ejemplo:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>1 \u00d7 100 G QSFP28<br\/>\u27a1\ufe0f puede convertirse en<\/p><\/li><li><p>4 \u00d7 conexiones SFP28 de 25 G (mediante cable divisor)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Esto permite:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Dise\u00f1o de red flexible<\/p><\/li><li><p>Actualizaciones graduales de 25 G a 100 G<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Consideraciones de compatibilidad<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A pesar de cierta flexibilidad, estos m\u00f3dulos NO son intercambiables directamente:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u274c QSFP28 no cabe en un puerto SFP<\/p><\/li><li><p>\u274c SFP no cabe en un puerto QSFP28<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Incluso con divisi\u00f3n:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Requiere:<\/p><ul><li><p>Soporte del conmutador<\/p><\/li><li><p>Configuraci\u00f3n correcta<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Compromiso entre costo y rendimiento<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 236px;\"\/><col style=\"width: 224px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"236\"><p>Factor<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"224\"><p>SFP<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>QSFP28<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"236\"><p>Costo por m\u00f3dulo<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"224\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Superior<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"236\"><p>Costo por Gbps<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"224\"><p>Superior<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"236\"><p>Escalabilidad<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"224\"><p>Limitado<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Excelente<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Para despliegues a gran escala: QSFP28 ofrece una mayor eficiencia a largo plazo, pese a su mayor costo inicial<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Gu\u00eda pr\u00e1ctica para la toma de decisiones<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Elija <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-25832-1-2-4g-transceiver-modules.htm\">SFP\/SFP28<\/a> si:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Necesita \u226425 G por enlace<\/p><\/li><li><p>El presupuesto es limitado<\/p><\/li><li><p>La red est\u00e1 centrada en la capa de acceso<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Elija <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">QSFP28<\/a> si:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Necesita ancho de banda de 100 G<\/p><\/li><li><p>Est\u00e1 construyendo una infraestructura escalable<\/p><\/li><li><p>Desea flexibilidad de divisi\u00f3n<\/p><\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>SFP = conexi\u00f3n de una sola v\u00eda, menor velocidad, conectividad perif\u00e9rica<\/p><\/li><li><p>QSFP28 = conexi\u00f3n de m\u00faltiples v\u00edas, alta velocidad, infraestructura central<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">No son tecnolog\u00edas competidoras: son complementarias y se usan en distintas capas de la red.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n, respondamos otra pregunta frecuente sobre despliegue: \u00bfQSFP28 es de modo \u00fanico o multimodo, y c\u00f3mo elegir el tipo adecuado?<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 \u00bfQSFP28 es de modo \u00fanico o multimodo? (Explicaci\u00f3n de SR4 frente a LR4)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP28 admite TANTO fibra de modo \u00fanico COMO multimodo; la diferencia depende del tipo espec\u00edfico de m\u00f3dulo (p. ej., SR4, LR4, CWDM4).<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/73675e435685433bb96b581d67c9400c.jpg\" alt=\"Is QSFP28 Single Mode or Multimode? (SR4 vs. LR4 Explained)\" class=\"wp-image-2828\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/73675e435685433bb96b581d67c9400c.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/73675e435685433bb96b581d67c9400c-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/73675e435685433bb96b581d67c9400c-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/73675e435685433bb96b581d67c9400c-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/73675e435685433bb96b581d67c9400c-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Comprensi\u00f3n de los dos tipos principales: SR4 frente a LR4<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\ud83d\udfe2 <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473116.htm\">QSFP28 SR4<\/a> (Fibra multimodo \u2013 MMF)<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">SR4 = Alcance corto (4 v\u00edas sobre fibra multimodo)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas clave:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Tipo de fibra: multimodo (OM3 \/ OM4)<\/p><\/li><li><p>Conector: MPO\/MTP (12 fibras)<\/p><\/li><li><p>Distancia t\u00edpica:<\/p><ul><li><p>~70 m (OM3)<\/p><\/li><li><p>~100 m (OM4)<\/p><\/li><\/ul><\/li><li><p>Longitud de onda: 850 nm<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ideal para:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Enlaces internos de centro de datos<\/p><\/li><li><p>Entornos de corta distancia y alta densidad<\/p><\/li><li><p>Implementaciones sensibles al costo<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">SR4 se usa ampliamente en arquitecturas hoja-espina dentro del mismo rack o fila<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\ud83d\udd35 <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/491587.htm\">QSFP28 LR4<\/a> (Fibra monomodo \u2013 SMF)<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">LR4 = Alcance largo (4 longitudes de onda multiplexadas sobre un par de fibras \u00fanico)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas clave:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Tipo de fibra: Monomodo (OS2)<\/p><\/li><li><p>Conector: LC d\u00faplex<\/p><\/li><li><p>Distancia t\u00edpica:<\/p><ul><li><p>Hasta 10 km<\/p><\/li><\/ul><\/li><li><p>Longitud de onda: CWDM (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/what-is-cwdm-understanding-coarse-wavelength-division-multiplexing\/\">multiplexaci\u00f3n por divisi\u00f3n de longitud de onda gruesa<\/a>)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ideal para:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Redes universitarias<\/p><\/li><li><p>Interconexi\u00f3n de centros de datos (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/data-center-interconnect-definition-benefits-and-role-of-optical-modules\/\">DCI<\/a>)<\/p><\/li><li><p>Enlaces de n\u00facleo a larga distancia<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">LR4 es ideal cuando la distancia supera los l\u00edmites de la fibra multimodo<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/products\/qsfp28-100g-sr4-vs-lr4-100g-transceiver-comparison\/\">SR4 frente a LR4<\/a>: Comparaci\u00f3n lado a lado<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 215px;\"\/><col style=\"width: 249px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"215\"><p>Caracter\u00edstica<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"249\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473118.htm\">SR4<\/a> (Multimodo)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472127.htm\">de LR4<\/a> (Monomodo)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"215\"><p>Tipo de fibra<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"249\"><p>FMM (OM3\/OM4)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodo (OS2)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"215\"><p>Conector<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"249\"><p>MPO\/MTP<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>puertos LC d\u00faplex<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"215\"><p>Distancia<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"249\"><p>\u2264100 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u226410 km<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"215\"><p>Coste (m\u00f3dulo)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"249\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Superior<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"215\"><p>Coste (fibra)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"249\"><p>M\u00e1s alta (cableado MPO)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>M\u00e1s baja (fibra LC sencilla)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"215\"><p>Caso de uso<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"249\"><p>Dentro del centro de datos<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de larga distancia<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h4 class=\"wp-block-heading\" >Errores comunes en implementaciones reales<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Basado en experiencia pr\u00e1ctica, muchos problemas derivan de la confusi\u00f3n entre SR4 y LR4:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u274c Mezcla de tipos de fibra<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\">M\u00f3dulo SR4<\/a> + fibra monomodo \u2192 <strong>fallo de enlace<\/strong><\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/488423.htm\">M\u00f3dulo LR4<\/a> + fibra multimodo \u2192 <strong>sin se\u00f1al<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u274c Incompatibilidad de conectores<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>MPO (SR4) \u2260 LC (LR4)<br\/>\ud83d\udc49 Requiere una infraestructura de cableado completamente distinta<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u274c \u00d3pticas sobredimensionadas (uso de LR4 en distancias muy cortas)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Usar LR4 en enlaces muy cortos puede provocar:<\/p><ul><li><p>Saturaci\u00f3n de la se\u00f1al<\/p><\/li><li><p>Aumento de la tasa de errores de bits<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >Compromiso entre coste y distancia<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Elegir entre SR4 y LR4 no es solo una cuesti\u00f3n t\u00e9cnica, sino tambi\u00e9n econ\u00f3mica:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Distancia corta (&lt;100 m): <\/strong>SR4 es globalmente m\u00e1s rentable<\/p><\/li><li><p><strong>Distancia larga (&gt;500 m\u201310 km): <\/strong>LR4 se convierte en la \u00fanica opci\u00f3n pr\u00e1ctica<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >C\u00f3mo elegir el tipo correcto de QSFP28<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Use este marco de decisi\u00f3n r\u00e1pido:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Distancia \u2264100 m \u2192 <strong>SR4 (multimodo)<\/strong><\/p><\/li><li><p>Distancia \u2265500 m \u2192 <strong>LR4 (monomodo)<\/strong><\/p><\/li><li><p>Infraestructura existente:<\/p><ul><li><p>Cableado MPO \u2192 SR4<\/p><\/li><li><p>Fibra LC \u2192 LR4<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>QSFP28 no est\u00e1 limitado a un solo tipo de fibra<\/p><\/li><li><p>Por el contrario, es una plataforma flexible que admite m\u00faltiples est\u00e1ndares \u00f3pticos<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La verdadera decisi\u00f3n es: distancia corta + menor coste (SR4) frente a distancia larga + mayor alcance (LR4)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n, analizaremos un problema cr\u00edtico en entornos reales: \u00bfpor qu\u00e9 los m\u00f3dulos QSFP28 compatibles con MSA siguen fallando en implementaciones reales?<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 \u00bfPor qu\u00e9 siguen fallando los m\u00f3dulos QSFP28 compatibles con MSA?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A pesar de estar etiquetados como \u201ccompatibles con MSA\u201d, los m\u00f3dulos QSFP28 no siempre funcionan de forma fiable en redes reales. Este es uno de los problemas m\u00e1s frustrantes \u2014y frecuentemente buscados\u2014 entre los ingenieros que despliegan enlaces de 100 G.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La raz\u00f3n fundamental es sencilla: el MSA define est\u00e1ndares de hardware, pero el rendimiento en entornos reales depende de muchos factores adicionales que NO est\u00e1n normalizados<strong>.<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/591f0528d82948bb8a3d85d3cb88aad9.jpg\" alt=\"Why MSA-Compliant QSFP28 Modules Still Fail?\" class=\"wp-image-2829\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/591f0528d82948bb8a3d85d3cb88aad9.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/591f0528d82948bb8a3d85d3cb88aad9-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/591f0528d82948bb8a3d85d3cb88aad9-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/591f0528d82948bb8a3d85d3cb88aad9-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/591f0528d82948bb8a3d85d3cb88aad9-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Bloqueo por fabricante y problemas de compatibilidad del EEPROM<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Muchos switches de red (especialmente de marcas importantes) implementan mecanismos de validaci\u00f3n espec\u00edficos del fabricante.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfQu\u00e9 ocurre:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>El switch lee los datos de la EEPROM del m\u00f3dulo.<\/p><\/li><li><p>Si el ID del fabricante no es reconocido:<\/p><ul><li><p>\u274c El puerto puede deshabilitarse.<\/p><\/li><li><p>\u274c Aparecen mensajes de advertencia.<\/p><\/li><li><p>\u274c Las funciones pueden quedar limitadas.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Impacto en entornos reales: <\/strong>Incluso si un m\u00f3dulo es f\u00edsicamente compatible: es posible que el sistema no lo acepte.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Incompatibilidad de firmware y FEC<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La correcci\u00f3n de errores por adelantado (FEC, por sus siglas en ingl\u00e9s) es cr\u00edtica para enlaces de 100 G, pero no est\u00e1 completamente estandarizada entre fabricantes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Problemas comunes:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Un dispositivo usa RS-FEC, otro usa FC-FEC.<\/p><\/li><li><p>Los valores predeterminados difieren entre switches.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Resultado:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u274c El enlace no se establece.<\/p><\/li><li><p>\u274c Altas tasas de error.<\/p><\/li><li><p>\u274c Fluctuaciones intermitentes del enlace.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Esta es una causa importante de escenarios del tipo \u201cdeber\u00eda funcionar, pero no lo hace\u201d.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Problemas en la capa \u00f3ptica (los m\u00e1s subestimados)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Incluso con m\u00f3dulos correctos, los problemas en la capa f\u00edsica pueden interrumpir los enlaces.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Causas frecuentes:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Conectores MPO sucios (muy comunes).<\/p><\/li><li><p>Desajuste de polaridad de la fibra.<\/p><\/li><li><p>Tipo de fibra incorrecto (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/smf-optical-transceiver-vs-mmf-optical-transceiver-guide\/\">Fibra multimodo (MMF) frente a fibra monomodo (SMF)<\/a>)<\/p><\/li><li><p>Potencia \u00f3ptica excesiva (enlaces cortos con LR4).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Detalle cr\u00edtico:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP28 utiliza 4 canales; si falla uno, todo el enlace de 100 G se interrumpe.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Variaciones de calidad en <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">M\u00f3dulos de terceros<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No todos los m\u00f3dulos \u201ccompatibles con MSA\u201d est\u00e1n construidos de igual manera.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Problemas observados:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Tasas m\u00e1s altas de fallo en \u00f3pticas de bajo costo.<\/p><\/li><li><p>Calidad de fabricaci\u00f3n inconsistente.<\/p><\/li><li><p>Dise\u00f1o t\u00e9rmico deficiente.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Resultado:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u274c Fallo prematuro del m\u00f3dulo.<\/p><\/li><li><p>\u274c Rendimiento inestable bajo carga.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Restricciones t\u00e9rmicas y de potencia<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los m\u00f3dulos QSFP28 consumen m\u00e1s potencia que las \u00f3pticas de menor velocidad.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Riesgos:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Sobrecalentamiento en switches de alta densidad.<\/p><\/li><li><p>Flujo de aire insuficiente.<\/p><\/li><li><p>Fallos inducidos por temperatura.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Especialmente comunes con:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>M\u00f3dulos de cobre (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/knowledge-center\/direct-attach-cables-dac-in-networking\/\">SFP significa:<\/a>)<\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482686.htm\">Transceptores SFP RJ45.<\/a><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Configuraci\u00f3n incorrecta y errores de breakout<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP28 admite modos de breakout, pero requiere una configuraci\u00f3n correcta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Errores comunes:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Modo de puerto incorrecto (100 G frente a 4\u00d725 G).<\/p><\/li><li><p>Cables de breakout no compatibles.<\/p><\/li><li><p>Desajuste en la configuraci\u00f3n del lado del switch.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Resultado:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u274c Sin enlace.<\/p><\/li><li><p>\u274c Velocidad reducida.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >La causa ra\u00edz: est\u00e1ndar frente a la realidad<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Capa<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>MSA cubre<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Riesgo real de fallo<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Ajuste f\u00edsico<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2705 S\u00ed<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Escaso<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Interfaz el\u00e9ctrica<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2705 S\u00ed<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ventaja Clave<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Comportamiento del firmware<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c No<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>High<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Condiciones \u00f3pticas<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c No<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Muy alta<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Compatibilidad con el fabricante<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u274c No<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Cr\u00edtico<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >C\u00f3mo reducir el riesgo de fallo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Basado en experiencia real de despliegue:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Antes del despliegue:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Verifique la lista de compatibilidad del switch.<\/p><\/li><li><p>Use m\u00f3dulos correctamente codificados.<\/p><\/li><li><p>Ajuste los par\u00e1metros de FEC<br><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Durante la instalaci\u00f3n:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Limpie todos los conectores de fibra (especialmente MPO)<\/p><\/li><li><p>Verifique el tipo de fibra y la polaridad<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Durante las pruebas:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Verificar los niveles de potencia \u00f3ptica<\/p><\/li><li><p>Supervise los contadores de errores y la estabilidad del enlace<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>El cumplimiento de MSA garantiza un punto de partida, no el \u00e9xito<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La mayor\u00eda de los fallos provienen de:<\/p><ul><li><p>Brechas de compatibilidad<\/p><\/li><li><p>Problemas de capa f\u00edsica<\/p><\/li><li><p>Inconsistencias de calidad<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para lograr un rendimiento fiable de 100 G, debe ir m\u00e1s all\u00e1 del est\u00e1ndar y centrarse en <strong>la validaci\u00f3n de extremo a extremo<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n, pasemos de los problemas a las soluciones: \u00bfC\u00f3mo puede garantizar la compatibilidad de QSFP28 y evitar estos problemas en despliegues reales?<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 C\u00f3mo garantizar la compatibilidad de QSFP28 en despliegues reales<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tras comprender por qu\u00e9 los m\u00f3dulos QSFP28 compatibles con MSA a\u00fan pueden fallar, el siguiente paso consiste en construir un flujo de trabajo fiable para su despliegue. En redes del mundo real, el \u00e9xito proviene de una validaci\u00f3n sistem\u00e1tica, no de suposiciones.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n se presenta un enfoque pr\u00e1ctico, probado en campo, utilizado por ingenieros para garantizar la compatibilidad y estabilidad.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/49fb32be119e435d8449bed5dadf9ce9.jpg\" alt=\"Ensure QSFP28 Compatibility in Real Deployments\" class=\"wp-image-2830\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/49fb32be119e435d8449bed5dadf9ce9.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/49fb32be119e435d8449bed5dadf9ce9-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/49fb32be119e435d8449bed5dadf9ce9-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/49fb32be119e435d8449bed5dadf9ce9-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/49fb32be119e435d8449bed5dadf9ce9-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Flujo de trabajo de validaci\u00f3n paso a paso<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >\u2705 Confirme la compatibilidad del switch y del firmware<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Comience con la capa m\u00e1s cr\u00edtica:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Consulte la lista de compatibilidad de hardware del switch (HCL)<\/p><\/li><li><p>Verifique:<\/p><ul><li><p>Tipos de m\u00f3dulos QSFP28 admitidos (SR4, LR4, etc.)<\/p><\/li><li><p>Requisitos de versi\u00f3n de firmware o sistema operativo<\/p><\/li><\/ul><\/li><li><p>Identifique:<\/p><ul><li><p>Restricciones de marca de fabricante<\/p><\/li><li><p>Codificaci\u00f3n EEPROM requerida<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consejo profesional:<\/strong> Incluso dentro del mismo modelo de switch, distintas versiones de firmware pueden modificar el comportamiento de compatibilidad.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\ud83d\udd0c Ajuste el tipo de \u00f3ptica al caso de uso<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Asegure la alineaci\u00f3n entre el m\u00f3dulo y la infraestructura:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Distancia:<\/p><ul><li><p>\u2264100 m \u2192 SR4 (fibra multimodo)<\/p><\/li><li><p>\u2265500 m \u2192 LR4 (fibra monomodo)<\/p><\/li><\/ul><\/li><li><p>Conector:<\/p><ul><li><p>MPO (SR4) frente a LC (LR4)<\/p><\/li><\/ul><\/li><li><p>Tipo de fibra:<\/p><ul><li><p>OM3\/OM4 frente a OS2<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Las \u00f3pticas incompatibles son una de las causas m\u00e1s comunes de fallo de enlace.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\u2699\ufe0f Alinee la correcci\u00f3n de errores (FEC) y la configuraci\u00f3n del puerto<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Configure ambos extremos del enlace:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Ajuste el modo FEC:<\/p><ul><li><p>RS-FEC frente a FC-FEC<\/p><\/li><\/ul><\/li><li><p>Establezca el modo de puerto correcto:<\/p><ul><li><p>100G frente a desglose (4\u00d725G)<\/p><\/li><\/ul><\/li><li><p>Aseg\u00farese de que la configuraci\u00f3n de auto-negociaci\u00f3n sea coherente<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Una alineaci\u00f3n incorrecta de FEC es un punto de fallo oculto pero cr\u00edtico.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\ud83e\uddfc Inspeccione y limpie la capa \u00f3ptica<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Nunca omita la inspecci\u00f3n f\u00edsica:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Limpie todos los conectores (especialmente MPO)<\/p><\/li><li><p>Verifique:<\/p><ul><li><p>Polaridad de la fibra<\/p><\/li><li><p>Integridad del cable<br><\/p><\/li><\/ul><\/li><li><p>Utilice:<\/p><ul><li><p>Microscopio de inspecci\u00f3n de fibra<\/p><\/li><li><p>Kits de limpieza<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Un solo canal sucio puede interrumpir todo el enlace de 100 G.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >\ud83e\uddea Realice pruebas previas al despliegue<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Antes de ponerlo en producci\u00f3n:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Medir:<\/p><ul><li><p>Potencia \u00f3ptica de transmisi\u00f3n y recepci\u00f3n (TX\/RX)<\/p><\/li><li><p>P\u00e9rdida de enlace (dB)<\/p><\/li><\/ul><\/li><li><p>Supervise:<\/p><ul><li><p>Contadores de errores<\/p><\/li><li><p>Estabilidad de la se\u00f1al<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Las pruebas en laboratorio reducen significativamente el riesgo de producci\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Lista de verificaci\u00f3n de compatibilidad QSFP28<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Use esta lista de verificaci\u00f3n antes de la implementaci\u00f3n:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Hardware y \u00f3ptica<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u2714 El tipo de m\u00f3dulo QSFP28 coincide con la distancia y la fibra<\/p><\/li><li><p>\u2714 El tipo de conector (MPO\/LC) coincide con el cableado<\/p><\/li><li><p>\u2714 El m\u00f3dulo est\u00e1 codificado para el switch de destino (si es necesario)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Switch y configuraci\u00f3n<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u2714 El firmware del switch admite el m\u00f3dulo<\/p><\/li><li><p>\u2714 Los ajustes de FEC coinciden en ambos extremos<\/p><\/li><li><p>\u2714 El modo de puerto est\u00e1 configurado correctamente<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Capa f\u00edsica<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u2714 El tipo de fibra (MMF\/SMF) es correcto<\/p><\/li><li><p>\u2714 Los conectores est\u00e1n limpios y sin da\u00f1os<\/p><\/li><li><p>\u2714 Se ha verificado la polaridad<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pruebas y validaci\u00f3n<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u2714 La potencia \u00f3ptica se encuentra dentro del rango seguro<\/p><\/li><li><p>\u2714 No hay errores CRC ni de bits<\/p><\/li><li><p>\u2714 El enlace es estable bajo carga<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Estrategia de selecci\u00f3n de proveedores (cr\u00edtica para la estabilidad)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Elegir el proveedor adecuado es tan importante como la validaci\u00f3n t\u00e9cnica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Priorice el soporte de compatibilidad<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Busque proveedores que ofrezcan:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>M\u00f3dulos pre-codificados para marcas espec\u00edficas<\/p><\/li><li><p>Garant\u00edas de compatibilidad<\/p><\/li><li><p>Documentaci\u00f3n t\u00e9cnica<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Equilibre costo y confiabilidad<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Los m\u00f3dulos de costo ultra bajo pueden:<\/p><ul><li><p>Tener tasas de fallo m\u00e1s altas<\/p><\/li><li><p>Carecer de pruebas adecuadas<\/p><\/li><\/ul><\/li><li><p>Los m\u00f3dulos premium:<\/p><ul><li><p>Ofrecen mayor consistencia<\/p><\/li><li><p>Reducen el riesgo a largo plazo<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La opci\u00f3n m\u00e1s econ\u00f3mica suele derivar en costos operativos m\u00e1s altos<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Eval\u00fae las pruebas y el control de calidad<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los proveedores confiables deben ofrecer:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Pruebas de envejecimiento (burn-in)<\/p><\/li><li><p>Validaci\u00f3n del rendimiento \u00f3ptico<\/p><\/li><li><p>Hojas de especificaciones claras<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Verifique el soporte y el proceso de RMA<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Seg\u00fan comentarios reales:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La sustituci\u00f3n r\u00e1pida importa m\u00e1s que el precio<\/p><\/li><li><p>Un soporte deficiente de RMA puede retrasar significativamente los proyectos<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mejor pr\u00e1ctica: evite el riesgo de un \u00fanico punto de fallo<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En lugar de depender de un solo proveedor:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Valide a 2\u20133 proveedores de confianza<\/p><\/li><li><p>Estandarice los procedimientos de prueba<\/p><\/li><li><p>Mantenga inventario de respaldo para enlaces cr\u00edticos<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para garantizar <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473134.htm\">QSFP28<\/a> la compatibilidad en implementaciones reales:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>No conf\u00ede \u00fanicamente en el cumplimiento de MSA<\/p><\/li><li><p>Siga un flujo de trabajo estructurado de validaci\u00f3n<\/p><\/li><li><p>Combinar:<\/p><ul><li><p>Alineaci\u00f3n t\u00e9cnica<\/p><\/li><li><p>Inspecci\u00f3n f\u00edsica<\/p><\/li><li><p>Confiabilidad del proveedor<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Una implementaci\u00f3n exitosa de 100G no se trata solo de elegir el m\u00f3dulo adecuado,<br\/>sino de validar todo el entorno del enlace de extremo a extremo<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n, integremos todo desde una perspectiva pr\u00e1ctica de compra: c\u00f3mo elegir m\u00f3dulos QSFP28 confiables (gu\u00eda de decisi\u00f3n + lista de verificaci\u00f3n)<strong>.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Buenas pr\u00e1cticas para elegir m\u00f3dulos QSFP28 fiables<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Implementar con \u00e9xito una red de 100 G comienza con la elecci\u00f3n adecuada <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">Los m\u00f3dulos QSFP28<\/a>. Incluso en 2026, los ingenieros siguen encontrando problemas causados por \u00f3pticas de baja calidad o incompatibles. Seguir buenas pr\u00e1cticas garantiza tanto el rendimiento como la fiabilidad a largo plazo.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0facd170f530413abe9b7c873b30df55.jpg\" alt=\"Choosing Reliable QSFP28 Modules Practices\" class=\"wp-image-2831\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0facd170f530413abe9b7c873b30df55.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0facd170f530413abe9b7c873b30df55-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0facd170f530413abe9b7c873b30df55-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0facd170f530413abe9b7c873b30df55-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0facd170f530413abe9b7c873b30df55-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\ud83d\udd39 1. Utilice un marco estructurado de adquisici\u00f3n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Al seleccionar m\u00f3dulos QSFP28, eval\u00fae las opciones en tres dimensiones cr\u00edticas:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A. Rendimiento frente a costo<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>M\u00f3dulos de alto rendimiento<\/strong>:<\/p><ul><li><p>Normalmente m\u00e1s costosos<\/p><\/li><li><p>Ofrecen tasas de fallo m\u00e1s bajas, mejor tolerancia t\u00e9rmica y soporte t\u00e9cnico m\u00e1s s\u00f3lido por parte del fabricante<\/p><\/li><\/ul><\/li><li><p><strong>M\u00f3dulos econ\u00f3micos<\/strong>:<\/p><ul><li><p>Costo inicial m\u00e1s bajo<\/p><\/li><li><p>Mayor riesgo de inestabilidad del enlace, problemas de compatibilidad o fallos prematuros<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Regla pr\u00e1ctica: <\/strong>Considere el costo por Gbps y la fiabilidad a largo plazo, no solo el precio inicial.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>B. Pruebas y certificaci\u00f3n<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Priorice siempre m\u00f3dulos que ofrezcan:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Certificaci\u00f3n respaldada por el fabricante<\/strong> para marcas principales de switches<\/p><\/li><li><p><strong>Validaci\u00f3n de cumplimiento<\/strong> con los est\u00e1ndares QSFP28 MSA (SR4, LR4, <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482370.htm\">CWDM4<\/a>)<\/p><\/li><li><p><strong>Informes de pruebas previas a la implementaci\u00f3n<\/strong> para potencia \u00f3ptica, tasa de errores de bits (BER) y compatibilidad con correcci\u00f3n de errores hacia adelante (FEC)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consejo profesional:<\/strong> Los m\u00f3dulos probados en despliegues reales son mucho m\u00e1s fiables que \u00f3pticas gen\u00e9ricas sin verificar etiquetadas como \u201ccompatibles con MSA\u201d.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>C. Reputaci\u00f3n y soporte del fabricante<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los fabricantes fiables reducen el riesgo operativo:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Proporcionan <strong>m\u00f3dulos precodificados o compatibles con la marca<\/strong><\/p><\/li><li><p>Ofrecen <strong>soporte t\u00e9cnico y reemplazos r\u00e1pidos (RMA)<\/strong><\/p><\/li><li><p>Mantienen <strong>calidad consistente y pruebas de envejecimiento (burn-in)<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\ud83d\udd39 2. Integre control de calidad (QA) y pruebas de laboratorio en su flujo de trabajo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Incluso despu\u00e9s de elegir un fabricante confiable:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Realice pruebas previas a la instalaci\u00f3n:<\/p><ul><li><p>Verificaci\u00f3n de potencia \u00f3ptica de transmisi\u00f3n\/recepci\u00f3n (TX\/RX)<\/p><\/li><li><p>Estabilidad del enlace bajo carga<\/p><\/li><li><p>Validaci\u00f3n de FEC y de configuraciones de divisi\u00f3n (breakout)<\/p><\/li><\/ul><\/li><li><p>Inspeccione todas las conexiones de fibra (MPO\/LC) y verifique la polaridad<\/p><\/li><li><p>Supervise el rendimiento mediante <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/es\/glossary\/ddm-dom-in-optical-transceivers\/\">DDM\/DOM<\/a> m\u00e9tricas<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Esto garantiza que su red de 100 G sea robusta antes de su despliegue en producci\u00f3n.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\ud83d\udd39 3. Adquiera m\u00f3dulos QSFP28 de confianza<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Para ingenieros y responsables de TI que buscan <strong>m\u00f3dulos QSFP28 de alta calidad y compatibles con MSA<\/strong> con fiabilidad comprobada:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consulte la <\/strong><a target=\"_self\" href=\"https:\/\/www.l-p.com\/\"><strong>Tienda oficial de LINK-PP<\/strong><\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Gama completa de m\u00f3dulos QSFP28 SR4, LR4 y CWDM4<\/p><\/li><li><p>Probados para compatibilidad entre distintos fabricantes<\/p><\/li><li><p>Incluye soporte t\u00e9cnico y garant\u00eda<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Comprar a un proveedor de confianza simplifica la implementaci\u00f3n y reduce el riesgo, lo que permite que los equipos se centren en la expansi\u00f3n de la red en lugar de solucionar problemas.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\ud83d\udd39 4. Conclusiones clave<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Eval\u00fae los m\u00f3dulos seg\u00fan su rendimiento, pruebas y reputaci\u00f3n del fabricante<\/strong><\/p><\/li><li><p><strong>No conf\u00ede \u00fanicamente en el cumplimiento de la MSA<\/strong>\u2014la verificaci\u00f3n en entornos reales es fundamental<\/p><\/li><li><p><strong>Utilice un marco estructurado para la compra<\/strong> para equilibrar coste y fiabilidad<\/p><\/li><li><p><strong>Colabore con un proveedor de confianza<\/strong> como LINK-PP para minimizar los riesgos de implementaci\u00f3n<\/p><\/li>\n<\/ul>\n\n\n\n<div><div widgetid=\"3ef779ac451211f099380a58fbc66727\" format=\"embedded\" data-widget-id=\"3ef779ac451211f099380a58fbc66727\" data-mode=\"production.zh\" style=\"display: block;\"><\/div><\/div>\n\n\n\n<script src=\"https:\/\/cdn.mylandingpages.co\/widgets\/platform\/platform.widget.js\" async=\"true\"><\/script>","protected":false},"excerpt":{"rendered":"<p>Comprenda las normas QSFP28 MSA, los l\u00edmites de compatibilidad y los riesgos reales. Aprenda a elegir \u00f3pticas 100G fiables y evitar fallos en la implementaci\u00f3n.<\/p>","protected":false},"author":1,"featured_media":2832,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-2833","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/2833","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/comments?post=2833"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/2833\/revisions"}],"predecessor-version":[{"id":10728,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/posts\/2833\/revisions\/10728"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media\/2832"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/media?parent=2833"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/categories?post=2833"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/es\/wp-json\/wp\/v2\/tags?post=2833"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}