{"id":6092,"date":"2025-05-26T00:00:00","date_gmt":"2025-05-26T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/100g-optical-transceiver-form-factors-guide\/"},"modified":"2026-06-22T09:32:45","modified_gmt":"2026-06-22T09:32:45","slug":"100g-optical-transceiver-form-factors-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/100g-optical-transceiver-form-factors-guide","title":{"rendered":"Una gu\u00eda exhaustiva sobre los factores de forma de los m\u00f3dulos transceptores \u00f3pticos de 100 G"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9518068f0117475d8d03da221617a028.jpg\" alt=\"A Comprehensive Guide to 100G Optical Transceiver Module Form Factors\" class=\"wp-image-6088\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9518068f0117475d8d03da221617a028.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9518068f0117475d8d03da221617a028-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9518068f0117475d8d03da221617a028-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9518068f0117475d8d03da221617a028-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9518068f0117475d8d03da221617a028-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ethernet de 100 G<\/strong> desempe\u00f1a un papel fundamental en las redes modernas al permitir la transmisi\u00f3n de datos a alta velocidad. Apoya la computaci\u00f3n en la nube, los centros de datos y tecnolog\u00edas emergentes como la red definida por software (SDN) y la virtualizaci\u00f3n de funciones de red (NFV). Innovaciones como la transmisi\u00f3n \u00f3ptica paralela y la modulaci\u00f3n de amplitud de impulsos (PAM4) mejoran el ancho de banda y las velocidades de transmisi\u00f3n de datos. Transceptores compactos como <strong>QSFP28<\/strong> ofrecen soluciones rentables para actualizaciones de infraestructura. Adem\u00e1s, una correcci\u00f3n de errores mejorada y la amplificaci\u00f3n \u00f3ptica garantizan una conectividad fiable, lo que convierte al Ethernet de 100 G en indispensable para redes de alta velocidad.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">Sin embargo, seleccionar el factor de forma adecuado para sus <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><span class=\"qc-p1-tag\" style=\"color: rgb(85, 75, 223);\"><strong>m\u00f3dulos transceptores \u00f3pticos de 100 G<\/strong><\/span><\/a><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> puede resultar dif\u00edcil debido a la variedad de opciones de empaquetado disponibles. Esta gu\u00eda explora los principales factores de forma de m\u00f3dulos transceptores \u00f3pticos de 100 G:<strong>CFP<\/strong>, <strong>CFP2<\/strong>, <strong>CFP4<\/strong>, <strong>CXP<\/strong>, \u03ba\u03b1\u03b9 <strong>QSFP28<\/strong>\u2014y destaca sus aplicaciones, ventajas y limitaciones. Ya sea que est\u00e9 actualizando su red u optimizando configuraciones existentes, comprender estos factores de forma garantiza compatibilidad y rendimiento sin interrupciones.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Principales factores de forma de m\u00f3dulos transceptores \u00f3pticos de 100 G<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">CFP (C Form-Factor Pluggable)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u03a4\u03bf \/ \u0397 \/ \u039f <strong>CFP (C Form-Factor Pluggable)<\/strong> fue uno de los primeros factores de forma dise\u00f1ados para aplicaciones de 100 G. Con dimensiones de 144,75 mm \u00d7 82 mm \u00d7 13,6 mm, admite una amplia gama de protocolos, incluidos <strong>100GBASE-SR4<\/strong>, <strong>LR4<\/strong>, \u03ba\u03b1\u03b9 <strong>ER4<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas clave:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Alto consumo de energ\u00eda<\/strong>: Normalmente consume entre 10 y 24 W, lo que lo hace menos eficiente energ\u00e9ticamente.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><a href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/multi-source-agreements-optical-transceivers\/\" target=\"_blank\" rel=\"\"><strong>Compatible con acuerdos multi-fabricante (MSA)<\/strong><\/a>: Garantiza la interoperabilidad entre distintos proveedores.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Aplicaciones<\/strong>: Despliegues iniciales de 100 G, redes de telecomunicaciones de largo alcance.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u0395\u03bd\u03ce <strong>m\u00f3dulos CFP<\/strong> sentaron las bases para la adopci\u00f3n de 100 G, su gran tama\u00f1o y alto consumo de energ\u00eda han llevado a su sustituci\u00f3n gradual por alternativas m\u00e1s compactas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">CFP2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El factor de forma CFP2 aborda las limitaciones de su predecesor al reducir el tama\u00f1o un 50 % (41,5 mm \u00d7 107,8 mm \u00d7 12,35 mm) y el consumo de energ\u00eda a 6\u201312 W.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas clave:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Mayor densidad<\/strong>: Ideal para entornos de centros de datos de alta densidad.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Soporte para modulaci\u00f3n avanzada<\/strong>: Permite la transmisi\u00f3n coherente de 100 G.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Aplicaciones<\/strong>: Redes metropolitanas, infraestructura en la nube.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>M\u00f3dulos CFP2<\/strong> lograr un equilibrio entre rendimiento y eficiencia, aunque siguen siendo m\u00e1s voluminosos que opciones m\u00e1s recientes como QSFP28.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">CFP4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El CFP4 reduce a\u00fan m\u00e1s la miniaturizaci\u00f3n de la familia CFP, reduciendo sus dimensiones a 21,5 mm \u00d7 92 mm \u00d7 9,5 mm y su consumo de energ\u00eda a 4\u20136 W.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas clave:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Dise\u00f1o compacto<\/strong>: Duplica la densidad de puertos en comparaci\u00f3n con CFP2.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Rentable<\/strong>: Un menor consumo de energ\u00eda y requisitos de espacio reducen el costo total de propiedad (TCO).<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Aplicaciones<\/strong>: Redes empresariales, configuraciones de desglose (breakout) de 100 G.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Los m\u00f3dulos CFP4<\/strong> son ideales para organizaciones que priorizan la eficiencia espacial sin comprometer el rendimiento.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">CXP<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u03a4\u03bf \/ \u0397 \/ \u039f <strong>CXP (CXP Form-Factor Pluggable)<\/strong> es un factor de forma especializado dise\u00f1ado espec\u00edficamente para <strong>aplicaciones de alcance ultra corto (USR, por sus siglas en ingl\u00e9s)<\/strong> como InfiniBand y computaci\u00f3n de alto rendimiento (HPC).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas clave:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Dise\u00f1o de 12 canales<\/strong>: Admite 100 G mediante 10 v\u00edas de 10 G.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Baja latencia<\/strong>: Optimizado para HPC y sistemas de negociaci\u00f3n financiera.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Aplicaciones<\/strong>: Cl\u00fasteres de servidores, supercomputaci\u00f3n.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aunque es menos com\u00fan en redes generales, CXP destaca en entornos especializados de alta velocidad.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">QSFP28 (Quad Small Form-Factor Pluggable 28)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>QSFP28<\/strong> se ha consolidado como el factor de forma dominante para 100 G, combinando un tama\u00f1o compacto (18,35 mm \u00d7 89,4 mm \u00d7 8,5 mm) con una eficiencia excepcional (m\u00e1x. 3,5 W).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas clave:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Alta densidad de puertos<\/strong>: Permite hasta 36 puertos por chasis de 1U.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>\u03a0\u03bb\u03b7\u03c1\u03bf\u03c6\u03bf\u03c1\u03b9\u03b1\u03ba\u03ae \u03b4\u03c5\u03bd\u03b1\u03bc\u03b9\u03ba\u03cc\u03c4\u03b7\u03c4\u03b1<\/strong>: Admite SR4, LR4, PSM4 y CWDM4.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Aplicaciones<\/strong>: Centros de datos en la nube, backhaul y fronthaul 5G.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La versatilidad y rentabilidad de QSFP28 lo convierten en la opci\u00f3n preferida para las implementaciones modernas de 100 G.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfPor qu\u00e9 los m\u00f3dulos QSFP28 de LINK-PP?<\/strong><br><strong>Los<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>Los transceptores \u00f3pticos QSFP28<\/strong><\/a> ofrecen confiabilidad y compatibilidad l\u00edderes en la industria, respaldados por una garant\u00eda de 5 a\u00f1os.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd0d944bd2634488a82f88d740189fd8-1024x576.jpg\" alt=\"Why LINK-PP\u2019s QSFP28 Modules?\" class=\"wp-image-6089\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd0d944bd2634488a82f88d740189fd8-1024x576.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd0d944bd2634488a82f88d740189fd8-300x169.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd0d944bd2634488a82f88d740189fd8-768x432.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd0d944bd2634488a82f88d740189fd8-18x10.jpg 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd0d944bd2634488a82f88d740189fd8.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Tabla comparativa: Factores de forma de transceptores \u00f3pticos de 100 G<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>\u03a6\u03bf\u03c1\u03bc\u03ac \u0394\u03b9\u03ac\u03c4\u03b1\u03be\u03b7\u03c2<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Dimensiones (mm)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Consumo de energ\u00eda<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Interfaz<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Aplicaciones clave<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Conectable en caliente<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>CFP<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>144,75 \u00d7 82 \u00d7 13,6<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10\u201324 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 \u00d7 10 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Telecomunicaciones, redes heredadas<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u039d\u03b1\u03b9<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>CFP2<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>107,8 \u00d7 41,5 \u00d7 12,35<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>6\u201312 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 25 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Redes metropolitanas<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u039d\u03b1\u03b9<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>CFP4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>92 \u00d7 21,5 \u00d7 9,5<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u20136 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 25 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Empresarial, centros de datos<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u039d\u03b1\u03b9<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>CXP<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>45 \u00d7 27 \u00d7 8,5<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>3,5\u20136 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>12 \u00d7 10 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>HPC, InfiniBand<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u039d\u03b1\u03b9<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>QSFP28<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>89,4 \u00d7 18,35 \u00d7 8,5<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2264 3,5 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 25 G o 1 \u00d7 100 G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Centros de datos en la nube, 5G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u039d\u03b1\u03b9<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Selecci\u00f3n del transceptor \u00f3ptico de 100 G adecuado<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Al seleccionar un <strong>m\u00f3dulo de 100 G<\/strong>, considere:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Densidad de puertos<\/strong>: QSFP28 y CFP4 destacan en entornos con restricciones de espacio.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>\u0391\u03c0\u03bf\u03b4\u03bf\u03c4\u03b9\u03ba\u03cc\u03c4\u03b7\u03c4\u03b1 \u0395\u03bd\u03ad\u03c1\u03b3\u03b5\u03b9\u03b1\u03c2<\/strong>: QSFP28 y CFP4 minimizan los costos operativos.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Requisitos de alcance<\/strong>: LR4\/ER4 para larga distancia, SR4\/PSM4 para corta distancia.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Compatibilidad<\/strong>: Aseg\u00farese de que est\u00e9 alineado con los switches y routers existentes.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Para las organizaciones que priorizan la preparaci\u00f3n para el futuro, QSFP28 es la opci\u00f3n recomendada debido a su amplia adopci\u00f3n y escalabilidad.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00bfPor qu\u00e9 asociarse con LINK-PP para sus necesidades de 100G?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En LINK-PP, nos especializamos en soluciones de transceptores \u00f3pticos de alto rendimiento adaptadas a las exigencias actuales de redes. Nuestros m\u00f3dulos de 100G se someten a pruebas rigurosas de interoperabilidad, garantizando una simplicidad de conexi\u00f3n y uso inmediato con plataformas OEM l\u00edderes como Cisco, Juniper y Arista.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00a1Explore nuestras soluciones hoy mismo!<\/strong><br>\u2705 <strong>Garant\u00eda l\u00edder en la industria<\/strong>: Cobertura de 5 a\u00f1os en todos los productos.<br>\u2705 <strong>Configuraciones personalizadas<\/strong>: Adaptadas a requisitos de red \u00fanicos.<br>\u2705 <strong>Soporte 24\/7<\/strong>: Asistencia experta para una integraci\u00f3n perfecta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfListo para actualizar?<\/strong><br><strong>P\u00f3ngase en contacto con LINK-PP<\/strong> para descubrir c\u00f3mo nuestro <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>100G \u03bf\u03c0\u03c4\u03b9\u03ba\u03bf\u03af \u03bc\u03b5\u03c4\u03b1\u03c4\u03c1\u03bf\u03c0\u03b5\u03af\u03c2<\/strong><\/a> puede optimizar la velocidad, eficiencia y retorno de la inversi\u00f3n (ROI) de su red.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Reflexiones finales<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Desde los m\u00f3dulos CFP heredados hasta las avanzadas soluciones QSFP28, la evoluci\u00f3n de los factores de forma de los transceptores \u00f3pticos de 100G refleja el impulso de la industria hacia una mayor densidad, menor consumo de energ\u00eda y mayor flexibilidad. Al alinear su elecci\u00f3n con las necesidades operativas y los objetivos futuros, puede garantizar una infraestructura de red robusta y escalable.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f2c7a61d1f184839bcc60c3a41f69066-1024x576.png\" alt=\"Link-PP\" class=\"wp-image-6090\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f2c7a61d1f184839bcc60c3a41f69066-1024x576.png 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f2c7a61d1f184839bcc60c3a41f69066-300x169.png 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f2c7a61d1f184839bcc60c3a41f69066-768x432.png 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f2c7a61d1f184839bcc60c3a41f69066-18x10.png 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f2c7a61d1f184839bcc60c3a41f69066.png 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mant\u00e9ngase a la vanguardia con LINK-PP<\/strong><br>Ya sea que est\u00e9 implementando un nuevo centro de datos o actualizando enlaces existentes, <strong>LINK-PP<\/strong>\u2019de <strong>100G \u03bf\u03c0\u03c4\u03b9\u03ba\u03bf\u03af \u03bc\u03b5\u03c4\u03b1\u03c4\u03c1\u03bf\u03c0\u03b5\u03af\u03c2<\/strong> ofrecen un rendimiento inigualable. Solicite una cotizaci\u00f3n ahora y \u00fanase a las empresas impulsadas por la conectividad de pr\u00f3xima generaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">V\u00e9ase tambi\u00e9n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/ddm-dom-in-optical-transceivers\/\">La importancia de la supervisi\u00f3n digital en los transceptores \u00f3pticos<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/wdm-optical-transceiver-module-applications\/\">Exploraci\u00f3n de la tecnolog\u00eda WDM y su papel en las redes \u00f3pticas<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/appearance-structure-optical-module\/\">\u00danase a nosotros en la experiencia comunitaria LINK-PP<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Comprenda los factores de forma de los transceptores \u00f3pticos de 100 G, como QSFP28, CFP, CFP2, CFP4 y CXP. Aprenda c\u00f3mo optimizan el rendimiento de la red y garantizan la compatibilidad.<\/p>","protected":false},"author":1,"featured_media":6091,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-6092","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/6092","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=6092"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/6092\/revisions"}],"predecessor-version":[{"id":11487,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/6092\/revisions\/11487"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/6091"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=6092"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=6092"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=6092"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}