{"id":5696,"date":"2025-07-24T00:00:00","date_gmt":"2025-07-24T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/1000base-lx-sfp-modern-network-fiber-compatibility-guide\/"},"modified":"2026-06-22T08:49:16","modified_gmt":"2026-06-22T08:49:16","slug":"1000base-lx-sfp-modern-network-fiber-compatibility-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/1000base-lx-sfp-modern-network-fiber-compatibility-guide","title":{"rendered":"\u039a\u03b1\u03c4\u03b1\u03bd\u03cc\u03b7\u03c3\u03b7 \u03c4\u03bf\u03c5 SFP 1000BASE-LX \u03b3\u03b9\u03b1 \u03c3\u03cd\u03b3\u03c7\u03c1\u03bf\u03bd\u03b1 \u03b4\u03af\u03ba\u03c4\u03c5\u03b1"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fd9dbe1d45bc40798a9187e158568c27.webp\" alt=\"What is 1000BASE-LX SFP\" class=\"wp-image-5694\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fd9dbe1d45bc40798a9187e158568c27.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fd9dbe1d45bc40798a9187e158568c27-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fd9dbe1d45bc40798a9187e158568c27-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fd9dbe1d45bc40798a9187e158568c27-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fd9dbe1d45bc40798a9187e158568c27-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">En las redes actuales, \u00e1vidas de ancho de banda, extender Ethernet Gigabit fiable m\u00e1s all\u00e1 de las limitaciones del cobre es esencial. Introduzca el<br> <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><span class=\"qc-p1-tag\"><strong>1000BASE-LX SFP<br><\/strong><\/span><\/a><span class=\"qc-p1-tag\"><strong> (Peque\u00f1o factor de forma enchufable)<br><\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> transceptor: la soluci\u00f3n principal para conexiones de fibra \u00f3ptica de larga distancia. Esta gu\u00eda definitiva profundiza en su tecnolog\u00eda, aplicaciones y por qu\u00e9 elegir el m\u00f3dulo adecuado, como las opciones de alto rendimiento de LINK-PP, es fundamental para la integridad de la red.<br>.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2756 \u00bfQu\u00e9 es un 1000BASE-LX SFP?<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>1000BASE-LX SFP<br><\/strong> es un m\u00f3dulo intercambiable en caliente<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>transceptor \u00f3ptico<\/strong><\/a> dise\u00f1ado para<br> <strong>Ethernet Gigabit<\/strong> (1000 Mbps) sobre cables de fibra \u00f3ptica. La \u201cLX\u201d significa \u201cLong Wavelength\u201d (longitud de onda larga), lo que indica su uso de<br> <strong>l\u00e1seres de 1310 nm<br><\/strong> optimizados para<br> <strong>\u03bf\u03bc\u03bf\u03bc\u03bf\u03c1\u03c6\u03b9\u03ba\u03ae \u03c6\u03b9\u03bb\u03bc \u03c6\u03cc\u03c1\u03bc\u03b1 (SMF)<\/strong>. Su ventaja principal es alcanzar distancias de hasta<br> <strong>10 kil\u00f3metros (6,2 millas)<br><\/strong>, superando ampliamente a los est\u00e1ndares 1000BASE-SX (multimodo) o de cobre.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Especificaciones clave y funcionamiento<br><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Est\u00e1ndar:<\/strong> IEEE 802.3 Cl\u00e1usula 38 (Ethernet Gigabit sobre fibra)<br><\/p><\/li><li><p style=\"margin: 0px;\"><strong>Tasa de datos:<\/strong> 1,25 Gbps (Gigabit Ethernet)<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Longitud de onda:<\/strong> 1310 nm<\/p><\/li><li><p style=\"margin: 0px;\"><strong>(MMF \u2013 OM3\/OM4\/OM5).<\/strong> Principalmente <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>Fibra monomodo (SMF)<\/strong><\/a>, com\u00fanmente<br> <strong>OS1<\/strong> \u03ae <strong>OS2<\/strong>. *Tambi\u00e9n puede funcionar sobre fibra multimodo (MMF), como OM1\/OM2, mediante un cable adaptador de modo (MCP), para distancias de hasta 550 m.*<br><\/p><\/li><li><p style=\"margin: 0px;\"><strong>Distancia m\u00e1xima:<\/strong> <strong>Hasta 10 km<br><\/strong> sobre fibra monomodo est\u00e1ndar (SMF). M\u00f3dulos de alta calidad, como el<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>LINK-PP LS-SM311G-10C<br><\/strong><\/a> logran esto de forma fiable.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Interfaz:<\/strong> Conector LC d\u00faplex<br><\/p><\/li><li><p style=\"margin: 0px;\"><strong>Soporte DDM (DOM):<br><\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/ddm-dom-in-optical-transceivers\/\">\u03a8\u03b7\u03c6\u03b9\u03b1\u03ba\u03ae \u039f\u03c0\u03c4\u03b9\u03ba\u03ae \u03a0\u03b1\u03c1\u03b1\u03ba\u03bf\u03bb\u03bf\u03cd\u03b8\u03b7\u03c3\u03b7 (DOM)<\/a> proporciona diagn\u00f3sticos en tiempo real (potencia de transmisi\u00f3n\/recepci\u00f3n, temperatura, voltaje).<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2756 Aplicaciones principales: d\u00f3nde destacan los 1000BASE-LX SFP<br><\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px;\"><strong>Conectividad entre edificios:<br><\/strong> Conexi\u00f3n de instalaciones separadas (campus, centros de datos, oficinas) a trav\u00e9s de calles o campus.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Recorridos largos de fibra:<br><\/strong> Cobertura de grandes complejos industriales, almacenes o redes municipales.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Enlaces troncales de fibra:<br><\/strong> Agregaci\u00f3n de tr\u00e1fico desde switches de acceso hacia capas n\u00facleo\/distribuci\u00f3n.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Redes de acceso de proveedores de servicios:<br><\/strong> Prestaci\u00f3n de servicios a clientes empresariales sobre infraestructura existente de SMF.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Extensiones de red:<br><\/strong> Superaci\u00f3n de los l\u00edmites de distancia del cobre (100 m) para IDFs remotos o dispositivos.<br>.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Consideraciones y mejores pr\u00e1cticas para la implementaci\u00f3n<br><\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px 0px 4px;\"><strong>Coincidencia del tipo de fibra:<br><\/strong> Aseg\u00farese de que su infraestructura utilice fibra monomodo (OS1\/OS2). El uso de MMF requiere un MCP en<br> <em>both<\/em> ambos extremos para distancias &gt;300 m.<br>.<\/p><ul><li><p style=\"margin: 0px;\"><strong>Consejo de LINK-PP:<br><\/strong> Nuestros m\u00f3dulos incluyen etiquetado claro sobre compatibilidad con SMF\/MMF.<br>.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Calidad del cable:<\/strong> Utilice SMF de OS2 para un rendimiento garantizado de 10 km, especialmente con l\u00e1seres antiguos.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Limpieza del conector:<\/strong> Los conectores LC contaminados son una causa principal de fallos y errores en los enlaces. \u00a1Inspeccione y limpie minuciosamente!<\/p><\/li><li><p style=\"margin: 0px;\"><strong>C\u00e1lculo del presupuesto de enlace:<\/strong> Aseg\u00farese de que (Potencia de transmisi\u00f3n \u2013 Sensibilidad del receptor) &gt; (P\u00e9rdida del cable + P\u00e9rdida del conector + P\u00e9rdida de empalme + Margen de seguridad).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Uso de DOM:<\/strong> Supervise los niveles de potencia \u00f3ptica (<code>show interfaces transceiver details<\/code> en Cisco; comandos similares en otras plataformas) de forma proactiva para detectar degradaci\u00f3n antes del fallo.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2756 SFP 1000BASE-LX frente a SFP 1000BASE-SX: Selecci\u00f3n del m\u00f3dulo de fibra Gigabit adecuado<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a2ba358d3757491b97b9abb70c09cb84.webp\" alt=\"1000BASE-LX vs 1000BASE-SX\" class=\"wp-image-5695\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a2ba358d3757491b97b9abb70c09cb84.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a2ba358d3757491b97b9abb70c09cb84-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a2ba358d3757491b97b9abb70c09cb84-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a2ba358d3757491b97b9abb70c09cb84-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a2ba358d3757491b97b9abb70c09cb84-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Caracter\u00edstica<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>1000BASE-LX SFP<br><\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>SFP 1000BASE-SX<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Longitud de onda<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>850nm<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tipo de fibra<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Principalmente fibra monomodo (SMF)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Fibra multimodo (MMF)<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Distancia m\u00e1xima<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Hasta 10 km (SMF)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>550 m (OM2), 300 m (OM1)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Coste (fibra)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Superior (coste del cable SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Inferior (coste del cable MMF)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Coste (m\u00f3dulo)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Normalmente ligeramente superior<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Normalmente inferior<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Ideal para<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Enlaces largos (&gt;550 m), SMF existente<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Alcance corto (&lt;550 m), cableado MMF<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2756 \u00bfPor qu\u00e9 elegir m\u00f3dulos originales y compatibles como LINK-PP?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El uso de transceptores de alta calidad y compatibles con MSA <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>los m\u00f3dulos SFP \u00f3pticos<\/strong><\/a> es imprescindible para la estabilidad de la red. <strong>LINK-PP<\/strong> ofrece:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Cumplimiento total de los est\u00e1ndares IEEE:<\/strong> Interoperabilidad garantizada con switches principales (Cisco, Juniper, HPE, Dell, Brocade, etc.).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Pruebas rigurosas:<\/strong> Pruebas exhaustivas antes y despu\u00e9s de la producci\u00f3n para asegurar que el rendimiento cumpla las especificaciones.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Garant\u00eda de por vida:<\/strong> Compromiso con la fiabilidad del producto.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ahorros de costos:<\/strong> Ahorros significativos frente a los precios de OEM sin sacrificar calidad.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Soporte DOM:<\/strong> Diagn\u00f3sticos en tiempo real para una gesti\u00f3n proactiva.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Bajo consumo de energ\u00eda:<\/strong> Reducci\u00f3n de los costes operativos y de la carga t\u00e9rmica.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Modelo recomendado de SFP 1000BASE-LX LINK-PP:<\/strong><br\/>Para un rendimiento fiable de 10 km sobre SMF, considere el <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/buy-ls-sm311g-10c.htm\"><strong>LS-SM311G-10C<br><\/strong><\/a>. Este <strong>transceptor SFP de alta calidad<\/strong> incluye:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Soporte de velocidades de bits de 1,25 Gbps<\/p><\/li><li><p style=\"margin: 0px;\">L\u00e1ser FP de 1310 nm y fotodiodos PIN, con transmisi\u00f3n de hasta 10 km sobre SMF<\/p><\/li><li><p style=\"margin: 0px;\">Soporte completo de DDM (DOM)<\/p><\/li><li><p style=\"margin: 0px;\">Soporte de rango amplio de temperaturas, opci\u00f3n est\u00e1ndar e industrial<\/p><\/li><li><p style=\"margin: 0px;\">Compatibilidad con principales fabricantes de switches<\/p><\/li><li><p style=\"margin: 0px;\">Dise\u00f1o conforme a MSA<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\">\u261b <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/file\/datasheet\/ls-sm311g-10c.pdf\"><strong>Dibujo del producto<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u261b <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/message-476763.htm\"><span class=\"qc-p1-tag\"><strong>Solicitar cotizaci\u00f3n<\/strong><\/span><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2756 Preguntas frecuentes: Respuestas a sus dudas sobre SFP 1000BASE-LX<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P: \u00bfPuedo usar un SFP 1000BASE-LX con fibra multimodo (MMF)?<\/strong><br\/><strong>A:<\/strong> S\u00ed, pero las distancias est\u00e1n limitadas (t\u00edpicamente 550 m como m\u00e1ximo para OM1\/OM2, 300 m sin MCP). Usted<br> <strong>ser expl\u00edcitamente configurado para<\/strong> utiliza un cable de conexi\u00f3n de acondicionamiento de modo (MCP) en<br> <em>both<\/em> los extremos para inyectar correctamente el l\u00e1ser en la fibra multimodo (MMF) y evitar problemas de retardo diferencial de modo (DMD). El rendimiento m\u00e1s all\u00e1 de los 550 m en MMF no est\u00e1 garantizado. Siempre se prefiere la fibra monomodo (SMF) para LX.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P: \u00bfCu\u00e1l es la diferencia entre los m\u00f3dulos SFP LX y LH?<br><\/strong><br\/><strong>A:<\/strong> \u201cLH\u201d (Long Haul, transporte a larga distancia) es un t\u00e9rmino espec\u00edfico del fabricante que suele referirse a m\u00f3dulos que superan los 10 km (por ejemplo, 20 km, 40 km o 80 km usando 1550 nm). El est\u00e1ndar 1000BASE-LX est\u00e1 definido para 5 km, pero com\u00fanmente alcanza los 10 km en SMF moderna. Siempre consulte la hoja t\u00e9cnica espec\u00edfica del m\u00f3dulo para conocer su distancia nominal.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P: \u00bfC\u00f3mo s\u00e9 si mi switch admite m\u00f3dulos SFP 1000BASE-LX?<br><\/strong><br\/><strong>A:<\/strong> Consulte la hoja t\u00e9cnica de su switch, su matriz de compatibilidad o utilice la CLI (<br><code>show inventory<br><\/code>, <code>show interface transceiver<br><\/code>). La mayor\u00eda de los switches Gigabit de nivel empresarial admiten m\u00f3dulos SFP LX.<br>. <strong>LINK-PP<\/strong> Proporciona listas de compatibilidad para plataformas importantes.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P: \u00bfPor qu\u00e9 mi enlace 1000BASE-LX es inestable o no se establece?<br><\/strong><br\/><strong>A:<\/strong> Las causas comunes incluyen:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Conectores de fibra sucios o da\u00f1ados (\u00a1L\u00cdMPELOS!).<br>.<\/p><\/li><li><p style=\"margin: 0px;\">Tipo incorrecto de fibra (uso de MMF sin MCP para distancias superiores a 300 m).<\/p><\/li><li><p style=\"margin: 0px;\">Presupuesto de enlace excedido (distancia demasiado larga, p\u00e9rdidas demasiado altas).<\/p><\/li><li><p style=\"margin: 0px;\">Cable de conexi\u00f3n defectuoso o empalme defectuoso.<\/p><\/li><li><p style=\"margin: 0px;\">Incompatibilidad del m\u00f3dulo (utilice <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/multi-source-agreements-optical-transceivers\/\">compatibles con el est\u00e1ndar MSA,<\/a> m\u00f3dulos como <strong>LINK-PP<\/strong>).<\/p><\/li><li><p style=\"margin: 0px;\">Compruebe los niveles de potencia de transmisi\u00f3n\/recepci\u00f3n mediante DOM.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P: \u00bfSigue siendo relevante 1000BASE-LX ahora que est\u00e1n disponibles 10G\/25G?<\/strong><br\/><strong>A:<\/strong> \u00a1Absolutamente! El Gigabit Ethernet sigue siendo fundamental para innumerables aplicaciones donde se necesitan enlaces de larga distancia fiables y rentables, y las \u00f3pticas\/cables de 10G+ son innecesarios o prohibitivos desde el punto de vista econ\u00f3mico. Los m\u00f3dulos SFP LX son una soluci\u00f3n madura y econ\u00f3mica para enlaces dedicados de 1 G o para la agregaci\u00f3n de tr\u00e1fico a menor velocidad sobre largas distancias.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2756 Conclusion<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u03a4\u03bf \/ \u0397 \/ \u039f <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>Transceptor 1000BASE-LX SFP<\/strong><\/a> sigue siendo una tecnolog\u00eda fundamental para una conectividad robusta de Gigabit Ethernet a larga distancia. Comprender sus especificaciones, los requisitos de implementaci\u00f3n (especialmente el tipo de fibra y el uso de MCP) y aprovechar herramientas de diagn\u00f3stico como DOM son fundamentales para su correcta implementaci\u00f3n. Para obtener un rendimiento garantizado, fiabilidad y ahorros significativos frente a los fabricantes originales, elija m\u00f3dulos compatibles con MSA de proveedores de confianza como <strong>LINK-PP<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u039f SFP 1000BASE-LX \u03b5\u03c0\u03b9\u03c4\u03c1\u03ad\u03c0\u03b5\u03b9 \u03b1\u03be\u03b9\u03cc\u03c0\u03b9\u03c3\u03c4\u03b5\u03c2 \u03c3\u03c5\u03bd\u03b4\u03ad\u03c3\u03b5\u03b9\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ae\u03c2 \u03af\u03bd\u03b1\u03c2 1 Gbps \u03bc\u03ad\u03c7\u03c1\u03b9 10 \u03c7\u03bb\u03bc., \u03c5\u03c0\u03bf\u03c3\u03c4\u03b7\u03c1\u03af\u03b6\u03bf\u03bd\u03c4\u03b1\u03c2 \u03c4\u03cc\u03c3\u03bf \u03bc\u03bf\u03bd\u03cc\u03c4\u03c1\u03bf\u03c0\u03b5\u03c2 \u03cc\u03c3\u03bf \u03ba\u03b1\u03b9 \u03c0\u03bf\u03bb\u03c5\u03c4\u03c1\u03cc\u03c0\u03bf\u03c5\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u03af\u03bd\u03b5\u03c2 \u03b3\u03b9\u03b1 \u03c3\u03cd\u03b3\u03c7\u03c1\u03bf\u03bd\u03b5\u03c2 \u03c3\u03c5\u03c3\u03ba\u03b5\u03c5\u03ad\u03c2 \u03b4\u03b9\u03ba\u03c4\u03cd\u03bf\u03c5.<\/p>","protected":false},"author":1,"featured_media":5694,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[26],"class_list":["post-5696","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5696","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=5696"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5696\/revisions"}],"predecessor-version":[{"id":11306,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5696\/revisions\/11306"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/5694"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=5696"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=5696"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=5696"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}