{"id":5689,"date":"2025-07-24T00:00:00","date_gmt":"2025-07-24T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/1000base-sx-sfp-gigabit-ethernet-multimode-fiber-explained\/"},"modified":"2026-06-22T08:48:45","modified_gmt":"2026-06-22T08:48:45","slug":"1000base-sx-sfp-gigabit-ethernet-multimode-fiber-explained","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/1000base-sx-sfp-gigabit-ethernet-multimode-fiber-explained","title":{"rendered":"\u03a4\u03b9 \u03b5\u03af\u03bd\u03b1\u03b9 \u03ad\u03bd\u03b1\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03cc\u03c2 \u03bc\u03b5\u03c4\u03b1\u03c4\u03c1\u03bf\u03c0\u03ad\u03b1\u03c2 SFP 1000BASE-SX"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2f6b29cf5f284a9bb78fc6e9b61f7130.webp\" alt=\"What is a 1000BASE-SX SFP\" class=\"wp-image-5687\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2f6b29cf5f284a9bb78fc6e9b61f7130.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2f6b29cf5f284a9bb78fc6e9b61f7130-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2f6b29cf5f284a9bb78fc6e9b61f7130-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2f6b29cf5f284a9bb78fc6e9b61f7130-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2f6b29cf5f284a9bb78fc6e9b61f7130-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">El Gigabit Ethernet sigue siendo la columna vertebral de innumerables redes empresariales y de centros de datos. Al implementar enlaces de alta velocidad sobre distancias relativamente cortas mediante fibra multimodo (MMF) rentable, el <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/478230.htm\"><span class=\"qc-p1-tag\"><strong>transceptor SFP 1000BASE-SX<\/strong><\/span><\/a><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> es el caballo de batalla indiscutible. Comprender sus especificaciones, capacidades y escenarios \u00f3ptimos de implementaci\u00f3n es fundamental para los ingenieros de redes y los especialistas en adquisiciones de TI.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 \u00bfQu\u00e9 es un m\u00f3dulo SFP 1000BASE-SX?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">A <strong>SFP 1000BASE-SX<\/strong> (<\/span><span class=\"qc-p1-tag\"><strong>S<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">peque\u00f1o <\/span><span class=\"qc-p1-tag\"><strong>F<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">factor de forma <\/span><span class=\"qc-p1-tag\"><strong>P<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">extra\u00edble) es un m\u00f3dulo compacto, intercambiable en caliente, <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><span class=\"qc-p1-tag\"><strong>\u0397 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ae \u03bc\u03bf\u03bd\u03ac\u03b4\u03b1<\/strong><\/span><\/a><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> dise\u00f1ado para la comunicaci\u00f3n Gigabit Ethernet (1000 Mbps). La designaci\u00f3n \u201cSX\u201d indica su uso con <\/span><span class=\"qc-p1-tag\"><strong>l\u00e1seres de corta longitud de onda<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> (850 nm) sobre <\/span><span class=\"qc-p1-tag\"><strong>fibra multimodo<\/strong><\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> (MMF)<\/span><\/a><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">. Estos m\u00f3dulos convierten las se\u00f1ales el\u00e9ctricas procedentes de conmutadores\/routers de red en se\u00f1ales \u00f3pticas para su transmisi\u00f3n por cableado de fibra y viceversa, permitiendo conexiones de alto ancho de banda y baja latencia.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tecnolog\u00eda principal y funcionamiento<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px;\"><strong>Fuente l\u00e1ser:<\/strong> Utiliza un <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/overview-of-vcsel\/\">L\u00e1ser emisor superficial de cavidad vertical (VCSEL)<\/a> que opera a 850 nm. Los VCSEL ofrecen fiabilidad, menor consumo de energ\u00eda y mayor rentabilidad en comparaci\u00f3n con los l\u00e1seres Fabry-Perot.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>(MMF \u2013 OM3\/OM4\/OM5).<\/strong> Dise\u00f1ado espec\u00edficamente para <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>fibra multimodo (OM1, OM2, OM3, OM4)<\/strong><\/a>. El di\u00e1metro del n\u00facleo de la fibra multimodo (50 \u00b5m o 62,5 \u00b5m) permite m\u00faltiples trayectorias de luz (modos).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Conectores LC d\u00faplex:<\/strong> Las interfaces d\u00faplex LC est\u00e1ndar de la industria garantizan una instalaci\u00f3n sencilla del cableado.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Codificaci\u00f3n:<\/strong> Emplea codificaci\u00f3n de l\u00ednea 8B\/10B (velocidad de l\u00ednea de 1,25 Gbps para datos de 1 Gbps).<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Especificaciones clave y rendimiento<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Comprender las limitaciones de distancia seg\u00fan el tipo de fibra es fundamental para una implementaci\u00f3n exitosa:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Tipo de fibra<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Di\u00e1metro del n\u00facleo (\u00b5m)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Distancia m\u00e1xima (SFP 1000BASE-SX)<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>OM1 (62,5 \u00b5m)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>62.5<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>300 metros<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>OM2 (50 \u00b5m)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>50<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>500 metros<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>OM3 (50 \u00b5m \u2013 optimizada para l\u00e1ser)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>50<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>los 550 metros<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>OM4 (50 \u00b5m \u2013 optimizada para l\u00e1ser)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>50<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>550 metros+<\/strong><\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Tasa de datos:<\/strong> 1,25 Gbps (Gigabit Ethernet)<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Longitud de onda:<\/strong> 850nm<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Soporte DOM:<\/strong> La mayor\u00eda de los SFP modernos, incluidos <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/478230.htm\"><strong>LS-MM851G-S5C<\/strong><\/a>, admitir <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/ddm-dom-in-optical-transceivers\/\">\u03a8\u03b7\u03c6\u03b9\u03b1\u03ba\u03ae \u039f\u03c0\u03c4\u03b9\u03ba\u03ae \u03a0\u03b1\u03c1\u03b1\u03ba\u03bf\u03bb\u03bf\u03cd\u03b8\u03b7\u03c3\u03b7 (DOM)<\/a>, lo que permite la supervisi\u00f3n en tiempo real de la temperatura, el voltaje y la potencia de transmisi\u00f3n\/recepci\u00f3n mediante el dispositivo host.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Bajo consumo de energ\u00eda:<\/strong> Normalmente &lt; 1 W.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Cumplimiento:<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/multi-source-agreements-optical-transceivers\/\">Acuerdo Multifabricante (MSA)<\/a> Las normas garantizan la interoperabilidad entre fabricantes.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Aplicaciones principales y casos de uso<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Espaldas de edificio:<\/strong> Conexi\u00f3n entre plantas o alas dentro de un edificio corporativo.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Racks de centros de datos:<\/strong> Enlaces desde el conmutador de parte superior del rack (ToR) hasta el conmutador de agregaci\u00f3n.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Grupos de trabajo de alto rendimiento:<\/strong> Interconexi\u00f3n de servidores o estaciones de trabajo de alta demanda.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fibra hasta el escritorio (FTTD):<\/strong> Para entornos que requieren inmunidad a interferencias electromagn\u00e9ticas (EMI) o preparaci\u00f3n para el futuro.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Sistemas de seguridad:<\/strong> Redes de videovigilancia de alto ancho de banda.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Selecci\u00f3n del m\u00f3dulo SFP 1000BASE-SX adecuado: compatibilidad y calidad<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u0395\u03bd\u03ce <strong>Compatibilidad del m\u00f3dulo SFP 1000BASE-SX<\/strong> es generalmente alta debido a los est\u00e1ndares MSA; considere estos factores:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px;\"><strong>Codificaci\u00f3n del fabricante del dispositivo host:<\/strong> Algunos switches (Cisco, Juniper, HPE) requieren una codificaci\u00f3n espec\u00edfica de identificaci\u00f3n del fabricante. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/478230.htm\"><strong>LINK-PP 1000BASE-SX<\/strong> <strong>m\u00f3dulos<\/strong><\/a> ofrecen una amplia compatibilidad y a menudo pueden ser codificados para marcas importantes (<em>verifique siempre la compatibilidad<\/em>).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Infraestructura de fibra:<\/strong> Ajuste el m\u00f3dulo al tipo de fibra instalada (OM1\/OM2\/OM3\/OM4) y a la distancia requerida. \u00bfNecesita 500 m? OM3\/OM4 es esencial.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Soporte DDM (DOM):<\/strong> Fundamental para la supervisi\u00f3n proactiva y soluci\u00f3n de problemas de la red.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Calidad y confiabilidad:<\/strong> Evite productos falsificados <strong>M\u00f3dulos SFP<\/strong>. Elija fabricantes reputados como LINK-PP, que ofrecen pruebas rigurosas, garant\u00edas y garant\u00edas de rendimiento. Aut\u00e9nticos <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>transceptores \u00f3pticos LINK-PP<\/strong><\/a> garantizan la integridad de la se\u00f1al y su durabilidad.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Soluci\u00f3n de problemas comunes con m\u00f3dulos SFP 1000BASE-SX<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>Enlace ca\u00eddo:<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Verifique el tipo de fibra (debe ser fibra multimodo, MMF) y los l\u00edmites de distancia.<\/p><\/li><li><p style=\"margin: 0px;\">Compruebe la polaridad de la fibra (la salida Tx en un extremo debe conectarse a la entrada Rx en el otro).<\/p><\/li><li><p style=\"margin: 0px;\">Inspeccione los conectores LC en busca de contaminaci\u00f3n (limpie con herramientas aprobadas).<\/p><\/li><li><p style=\"margin: 0px;\">Aseg\u00farese de que el m\u00f3dulo est\u00e9 completamente insertado en el <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/what-is-fiber-optic-cage\/\"><strong>carcasa SFP<\/strong><\/a>.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Tasas de error elevadas:<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Revise las lecturas DOM para detectar potencia de transmisi\u00f3n marginal o potencia de recepci\u00f3n baja.<\/p><\/li><li><p style=\"margin: 0px;\">Inspeccione la fibra en busca de curvaturas, roturas o empalmes\/conexiones deficientes.<\/p><\/li><li><p style=\"margin: 0px;\">Verifique que el di\u00e1metro del n\u00facleo de la fibra coincida con las especificaciones esperadas por el m\u00f3dulo.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 \u00bfPor qu\u00e9 elegir los m\u00f3dulos SFP 1000BASE-SX de LINK-PP?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/930c414805c649888c14da355c63c7ba.webp\" alt=\"1000BASE-SX SFP\" class=\"wp-image-5688\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/930c414805c649888c14da355c63c7ba.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/930c414805c649888c14da355c63c7ba-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/930c414805c649888c14da355c63c7ba-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/930c414805c649888c14da355c63c7ba-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/930c414805c649888c14da355c63c7ba-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP se destaca en el competitivo <strong>mercado de m\u00f3dulos \u00f3pticos<\/strong> al ofrecer:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Alto rendimiento y confiabilidad:<\/strong> Rigurosamente probados <strong>\u039f\u03b9 \u03bc\u03bf\u03bd\u03ac\u03b4\u03b5\u03c2 \u03bc\u03b5\u03c4\u03b1\u03b2\u03af\u03b2\u03b1\u03c3\u03b7\u03c2 LINK-PP<\/strong> cumplen o superan las especificaciones IEEE 802.3z y <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/multi-source-agreements-optical-transceivers\/\">MSA<\/a> para una integraci\u00f3n perfecta.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Rentabilidad:<\/strong> Ahorros significativos comparados con los m\u00f3dulos OEM sin comprometer la calidad: ideal para <strong>actualizaciones de red econ\u00f3micas<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Amplia compatibilidad:<\/strong> <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/478230.htm\"><strong>1000BASE-SX<\/strong><\/a> los m\u00f3dulos est\u00e1n dise\u00f1ados para una interoperabilidad amplia entre las principales marcas de switches.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Soporte completo DOM:<\/strong> Funcionalidades de supervisi\u00f3n en tiempo real para una gesti\u00f3n proactiva de la red.<\/p><\/li><li><p style=\"margin: 0px;\"><span class=\"qc-p1-tag\"><strong>Garant\u00eda de por vida y soporte t\u00e9cnico:<\/strong> Confianza en su inversi\u00f3n respaldada por asistencia especializada.<\/span><\/p><\/li>\n<\/ul>\n\n\n\n<div><div widgetid=\"3ef779ac451211f099380a58fbc66727\" format=\"embedded\" data-widget-id=\"3ef779ac451211f099380a58fbc66727\" data-mode=\"production.zh\" style=\"display: block;\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Conclusi\u00f3n: Impulsando una conectividad eficiente y de alta velocidad<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u03a4\u03bf \/ \u0397 \/ \u039f <strong>SFP 1000BASE-SX<\/strong> sigue siendo un componente vital para implementar redes robustas y de alto rendimiento Gigabit Ethernet sobre infraestructura de fibra multimodo. Su combinaci\u00f3n de velocidad, asequibilidad y relativa facilidad de implementaci\u00f3n lo convierte en ideal para innumerables aplicaciones empresariales y de centros de datos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfListo para optimizar su red con \u00f3pticas confiables y de alto rendimiento?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&gt;&gt; <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/message.htm\"><strong>\u00a1Compre hoy los m\u00f3dulos LINK-PP LS-MM851G-S5C 1000BASE-SX!<\/strong><\/a><strong> &lt;&lt;<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 \u03a3\u03c5\u03c7\u03bd\u03ad\u03c2 \u0395\u03c1\u03c9\u03c4\u03ae\u03c3\u03b5\u03b9\u03c2<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfPuede usar un SFP 1000BASE-SX con fibra monomodo?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No debe usar un SFP 1000BASE-SX con fibra monomodo. Este m\u00f3dulo funciona mejor con fibra multimodo. Usar fibra monomodo puede provocar se\u00f1ales d\u00e9biles o ninguna conexi\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfC\u00f3mo saber si su dispositivo admite SFP 1000BASE-SX?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Consulte el manual de su dispositivo o busque puertos SFP etiquetados como \u201cSX\u201d o \u201c1G\u201d. Tambi\u00e9n puede visitar el sitio web del fabricante para obtener una lista de compatibilidad. Aseg\u00farese siempre de que el tipo de SFP coincida con las especificaciones de su dispositivo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 ocurre si mezcla distintos tipos de SFP en un mismo switch?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mezclar tipos de SFP puede causar problemas de red. Debe usar el mismo tipo en ambos extremos de un enlace. Por ejemplo, use m\u00f3dulos 1000BASE-SX SFP en ambos lados para una conexi\u00f3n estable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfEs necesario limpiar los conectores SFP antes de usarlos?<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\u00a1S\u00ed! El polvo o la suciedad pueden bloquear la se\u00f1al luminosa. Siempre limpie los conectores LC con una herramienta de limpieza de fibra \u00f3ptica antes de conectarlos. Este paso le ayuda a obtener el mejor rendimiento y evita problemas de conexi\u00f3n.<\/p><\/blockquote>\n\n\n\n<script src=\"https:\/\/cdn.mylandingpages.co\/widgets\/platform\/platform.widget.js\" async=\"true\"><\/script>","protected":false},"excerpt":{"rendered":"<p>\u0388\u03bd\u03b1\u03c2 SFP 1000BASE-SX \u03b5\u03af\u03bd\u03b1\u03b9 \u03ad\u03bd\u03b1\u03c2 \u03b3\u03b9\u03b3\u03b1\u03bc\u03c0\u03b9\u03c4 \u03bc\u03b5\u03c4\u03b1\u03c4\u03c1\u03bf\u03c0\u03ad\u03b1\u03c2 \u03b3\u03b9\u03b1 \u03c0\u03bf\u03bb\u03c5\u03c4\u03c1\u03cc\u03c0\u03bf\u03c5\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u03af\u03bd\u03b5\u03c2, \u03c0\u03bf\u03c5 \u03b5\u03c0\u03b9\u03c4\u03c1\u03ad\u03c0\u03b5\u03b9 \u03c3\u03c5\u03bd\u03b4\u03ad\u03c3\u03b5\u03b9\u03c2 Ethernet 1 Gbps \u03bc\u03ad\u03c7\u03c1\u03b9 550 \u03bc\u03ad\u03c4\u03c1\u03b1 \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03ce\u03bd\u03c4\u03b1\u03c2 \u03bc\u03ae\u03ba\u03bf\u03c2 \u03ba\u03cd\u03bc\u03b1\u03c4\u03bf\u03c2 850 nm.<\/p>","protected":false},"author":1,"featured_media":5687,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[26],"class_list":["post-5689","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=5689"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5689\/revisions"}],"predecessor-version":[{"id":11304,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5689\/revisions\/11304"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/5687"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=5689"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=5689"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=5689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}