{"id":5577,"date":"2025-08-02T00:00:00","date_gmt":"2025-08-02T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/fec-forward-error-correction-in-optical-communication\/"},"modified":"2026-06-22T08:42:28","modified_gmt":"2026-06-22T08:42:28","slug":"fec-forward-error-correction-in-optical-communication","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/fec-forward-error-correction-in-optical-communication","title":{"rendered":"\u00bfQu\u00e9 es la correcci\u00f3n de errores hacia adelante (FEC) en comunicaciones \u00f3pticas?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d91539e3f2f4415994b3a16805190dd.jpg\" alt=\"What Is FEC?\" class=\"wp-image-5576\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d91539e3f2f4415994b3a16805190dd.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d91539e3f2f4415994b3a16805190dd-300x178.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d91539e3f2f4415994b3a16805190dd-1024x608.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d91539e3f2f4415994b3a16805190dd-768x456.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9d91539e3f2f4415994b3a16805190dd-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u0394\u03b9\u03cc\u03c1\u03b8\u03c9\u03c3\u03b7 \u03a3\u03c6\u03b1\u03bb\u03bc\u03ac\u03c4\u03c9\u03bd \u03a0\u03c1\u03bf\u03c2 \u03a4\u03b1 \u0395\u03bc\u03c0\u03c1\u03cc\u03c2 (FEC)<\/strong> es una tecnolog\u00eda fundamental en los sistemas modernos de comunicaci\u00f3n \u00f3ptica, especialmente crucial para la transmisi\u00f3n de datos a alta velocidad sobre largas distancias. Mejora la integridad de los datos al permitir que el receptor detecte y corrija errores de bits sin necesidad de retransmisi\u00f3n. Esta capacidad mejora la fiabilidad, eficiencia y rendimiento de las redes \u00f3pticas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En este art\u00edculo, exploraremos qu\u00e9 es la FEC, c\u00f3mo funciona, los tipos de c\u00f3digos utilizados, su papel en <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">Transceptores \u00f3pticos<\/a>, est\u00e1ndares comunes de Ethernet y consideraciones pr\u00e1cticas para su implementaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 \u00bfQu\u00e9 es la correcci\u00f3n de errores hacia adelante (FEC)?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La correcci\u00f3n de errores hacia adelante (FEC) es una t\u00e9cnica de procesamiento de se\u00f1ales digitales que a\u00f1ade bits redundantes a una secuencia de datos, lo que permite al receptor identificar y corregir proactivamente errores de transmisi\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En redes \u00f3pticas de alta velocidad (por ejemplo, 25G, 100G, 200G, 400G), la FEC es esencial para:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Reducir <strong>Tasa de errores de bits (<\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>BER<\/strong><\/a><strong>)<\/strong><\/p><\/li><li><p>Soporte para <strong>mayores distancias de transmisi\u00f3n<\/strong><\/p><\/li><li><p>Garantizar <strong>integridad de la se\u00f1al<\/strong> en condiciones ruidosas o con p\u00e9rdidas<\/p><\/li><li><p>Mantener la <strong>y cobertura de garant\u00eda m\u00e1s prolongada.<\/strong> en entornos multivendor<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2699\ufe0f \u00bfC\u00f3mo funciona la FEC?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La FEC codifica los datos de salida con bits adicionales basados en reglas matem\u00e1ticas bien definidas. El receptor utiliza estos bits para detectar y corregir un n\u00famero limitado de errores causados por deterioros como dispersi\u00f3n, ruido o diafon\u00eda.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Tipos comunes de c\u00f3digos FEC:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>C\u00f3digos Reed-Solomon (RS)<\/strong><br\/>C\u00f3digos por bloques ampliamente utilizados en Ethernet y transceptores \u00f3pticos. Las configuraciones RS(528,514) y RS(544,514) pueden corregir m\u00faltiples errores de s\u00edmbolo y son adecuadas para la correcci\u00f3n de errores en r\u00e1faga.<\/p><\/li><li><p><strong>C\u00f3digos BCH (Bose\u2013Chaudhuri\u2013Hocquenghem)<\/strong><br\/>C\u00f3digos binarios que ofrecen una alta correcci\u00f3n de errores con baja latencia, utilizados a veces en sistemas con restricciones de hardware. Su uso en sistemas modernos <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">PAM4<\/a> es limitado.<\/p><\/li><li><p><strong>C\u00f3digos LDPC (Low-Density Parity-Check)<\/strong><br\/>Conocidos por su rendimiento cercano al l\u00edmite de Shannon, los c\u00f3digos LDPC se adoptan en Ethernet de 400G\/800G y sistemas coherentes. Proporcionan una correcci\u00f3n superior para altas tasas de errores de s\u00edmbolo, pero requieren decodificadores m\u00e1s complejos e introducen mayor latencia.<\/p><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>\ud83d\udd0d Ejemplos:<\/strong><\/p><p>En sistemas Ethernet de 100G como <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488452.htm\"><strong>100GBASE-LR4<\/strong><\/a>, se emplea la correcci\u00f3n de errores basada en Reed-Solomon (RS-FEC, t\u00edpicamente RS(528,514)) para compensar las alteraciones \u00f3pticas en enlaces de fibra de largo alcance. Garantiza que el sistema pueda cumplir con un objetivo de BER posterior a FEC de 10\u207b\u00b9\u00b2 o mejor, incluso cuando la BER previa a FEC pueda estar en el rango de 10\u207b\u00b3.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83e\udde9 \u00bfPor qu\u00e9 es importante la correcci\u00f3n de errores (FEC) en los transceptores \u00f3pticos?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La correcci\u00f3n de errores (FEC) es fundamental en <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">m\u00f3dulos \u00f3pticos<\/a>, especialmente a velocidades de 25 Gbps y superiores. Permite:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u2705 Funcionamiento fiable en recorridos m\u00e1s largos de fibra<\/p><\/li><li><p>\u2705 Compatibilidad con componentes \u00f3pticos de menor calidad<\/p><\/li><li><p>\u2705 Interoperabilidad perfecta entre equipos de distintos fabricantes<\/p><\/li><li><p>\u2705 Cumplimiento de objetivos rigurosos de BER, particularmente en <strong>PAM4<\/strong> sistemas modulados<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La FEC permite utilizar componentes \u00f3pticos rentables al compensar limitaciones f\u00edsicas mediante correcci\u00f3n digital. Sin embargo, <strong>la latencia introducida por la FEC<\/strong> y el tipo de FEC empleado deben ajustarse a los requisitos del sistema y a las normas admitidas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udccf Normas comunes de FEC en Ethernet<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Est\u00e1ndar<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Tipo de FEC<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Aplicaci\u00f3n<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>IEEE 802.3bj<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>RS(528,514)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100GBASE-CR4, 100GBASE-KR4 (NRZ)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>IEEE 802.3by<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>RS(528,514)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>25GBASE-CR-S (NRZ)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>IEEE 802.3cd<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>KP4-FEC (RS(544,514))<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>50G, 100G, 200G (PAM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>100G Lambda MSA<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>RS(544,514)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u00d3ptica PAM4 de 100G de una sola v\u00eda<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\ud83d\udd0e <strong>Nota<\/strong>: RS(544,514), tambi\u00e9n conocida como KP4-FEC, es una variante m\u00e1s robusta requerida en sistemas basados en PAM4 debido a sus tasas de error de s\u00edmbolo inherentemente m\u00e1s altas. Desactivar la FEC en tales enlaces generalmente no est\u00e1 permitido por las normas.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >\u26a0\ufe0f Consideraciones clave para la implementaci\u00f3n de FEC<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>La FEC debe habilitarse en ambos extremos<\/strong> del enlace \u00f3ptico. Las configuraciones desalineadas (por ejemplo, FEC habilitada en un extremo y deshabilitada en el otro) pueden impedir el establecimiento del enlace o provocar una BER elevada.<\/p><\/li><li><p><strong>Los sistemas PAM4<\/strong>, como 100G DR, 200G FR4 o 400G DR4, <strong>requieren FEC<\/strong> para cumplir con los objetivos m\u00ednimos de BER debido al formato de modulaci\u00f3n m\u00e1s denso.<\/p><\/li><li><p><strong>La FEC a\u00f1ade latencia<\/strong> (por ejemplo, ~100 ns\u2013200 ns para KP4-FEC), lo cual puede ser significativo en aplicaciones sensibles a la latencia.<\/p><\/li><li><p><strong>BER posterior a FEC frente a BER previa a FEC<\/strong>: La mayor\u00eda de las especificaciones de sistema hacen referencia a la BER posterior a FEC. Comprender esta distinci\u00f3n es fundamental al evaluar el rendimiento del sistema.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd0c Soporte de FEC en los m\u00f3dulos \u00f3pticos LINK-PP<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u03a3\u03c4\u03b7\u03bd <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/\"><strong>LINK-PP<\/strong><\/a>, muchos de nuestros transceptores est\u00e1n dise\u00f1ados para ofrecer compatibilidad total con FEC seg\u00fan las normas IEEE y MSA:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Ejemplo de producto<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>FEC compatible<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Caso de uso<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28-page2.htm?ca=1469&amp;cv=8172\">SFP28 SR de 25 G<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>RS(528,514)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de corto alcance en centros de datos<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473140.htm\">100G QSFP28 CWDM4<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>RS(528,514) \/ KP4 opcional<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces PAM4 de 2 km<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26045-400g-qsfp-dd-osfp-qsfp112.htm\">400G OSFP DR4<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>KP4-FEC (RS(544,514))<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces PAM4 de 500 m a 2 km<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Todos los m\u00f3dulos se prueban para interoperabilidad, tolerancia a FEC y cumplimiento de las especificaciones de interfaz f\u00edsica y el\u00e9ctrica.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2753 Preguntas frecuentes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P1: \u00bfEl FEC lo gestiona el transceptor o el equipo host?<\/strong><br\/>R: El FEC normalmente se implementa en el dispositivo host (p. ej., MAC del switch\/<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/what-is-phy-physical-layer-basics-explained\/\">PHY<\/a>). La mayor\u00eda de los m\u00f3dulos \u00f3pticos no incluyen l\u00f3gica FEC, pero est\u00e1n dise\u00f1ados para ser compatibles con se\u00f1ales que la utilizan.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P2: \u00bfPuedo desactivar el FEC en mi red?<\/strong><br\/>R: Depende. En enlaces NRZ (p. ej., <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\">SFP+ 10G<\/a>), el FEC puede ser opcional. Sin embargo, en sistemas basados en PAM4, el FEC es obligatorio seg\u00fan la norma y su desactivaci\u00f3n podr\u00eda hacer inutilizable el enlace.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El FEC ya no es opcional: es esencial para mantener la integridad de las comunicaciones \u00f3pticas de alta velocidad, especialmente al escalar hacia PAM4 y enlaces de clase terabit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ya sea que est\u00e9 implementando <strong>25G<\/strong> Ethernet o escalando hacia <strong>800G<\/strong>, \u03ba\u03b1\u03c4\u03b1\u03bd\u03bf\u03ce\u03bd\u03c4\u03b1\u03c2 \u03c0\u03ce\u03c2 \u03bb\u03b5\u03b9\u03c4\u03bf\u03c5\u03c1\u03b3\u03b5\u03af \u03b7 FEC\u2014\u03ba\u03b1\u03b9 \u03b5\u03c0\u03b9\u03bb\u03ad\u03b3\u03bf\u03bd\u03c4\u03b1\u03c2 \u03bc\u03bf\u03bd\u03ac\u03b4\u03b5\u03c2 \u03c0\u03bf\u03c5 \u03c5\u03c0\u03bf\u03c3\u03c4\u03b7\u03c1\u03af\u03b6\u03bf\u03c5\u03bd \u03c0\u03bb\u03ae\u03c1\u03c9\u03c2 \u03c4\u03b1 \u03b1\u03c0\u03b1\u03b9\u03c4\u03bf\u03cd\u03bc\u03b5\u03bd\u03b1 \u03c0\u03c1\u03cc\u03c4\u03c5\u03c0\u03b1 FEC\u2014\u03b4\u03b9\u03b1\u03c3\u03c6\u03b1\u03bb\u03af\u03b6\u03b5\u03c4\u03b5 \u03c4\u03b7 \u03bc\u03b1\u03ba\u03c1\u03bf\u03c0\u03c1\u03cc\u03b8\u03b5\u03c3\u03bc\u03b7 \u03c3\u03c4\u03b1\u03b8\u03b5\u03c1\u03cc\u03c4\u03b7\u03c4\u03b1, \u03c3\u03c5\u03bc\u03b2\u03b1\u03c4\u03cc\u03c4\u03b7\u03c4\u03b1 \u03ba\u03b1\u03b9 \u03b1\u03c0\u03cc\u03b4\u03bf\u03c3\u03b7 \u03c4\u03bf\u03c5 \u03b4\u03b9\u03ba\u03c4\u03cd\u03bf\u03c5.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\ud83d\udd27 <strong>\u03a3\u03c5\u03bc\u03b2\u03bf\u03c5\u03bb\u03ae \u03b3\u03b9\u03b1 \u03c4\u03b7\u03bd \u03b5\u03b3\u03ba\u03b1\u03c4\u03ac\u03c3\u03c4\u03b1\u03c3\u03b7<\/strong>: \u0392\u03b5\u03b2\u03b1\u03b9\u03c9\u03b8\u03b5\u03af\u03c4\u03b5 \u03c0\u03ac\u03bd\u03c4\u03b1 \u03cc\u03c4\u03b9 \u03bf\u03b9 \u03c1\u03c5\u03b8\u03bc\u03af\u03c3\u03b5\u03b9\u03c2 FEC \u03b5\u03bd\u03b5\u03c1\u03b3\u03bf\u03c0\u03bf\u03b9\u03bf\u03cd\u03bd\u03c4\u03b1\u03b9 \u03ae \u03b1\u03c0\u03b5\u03bd\u03b5\u03c1\u03b3\u03bf\u03c0\u03bf\u03b9\u03bf\u03cd\u03bd\u03c4\u03b1\u03b9 \u03c3\u03c5\u03bd\u03b5\u03c0\u03ce\u03c2 \u03ba\u03b1\u03b9 \u03c3\u03c4\u03b1 \u03b4\u03cd\u03bf \u03ac\u03ba\u03c1\u03b1 \u03c4\u03b7\u03c2 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7\u03c2 \u03b3\u03b9\u03b1 \u03bd\u03b1 \u03b1\u03c0\u03bf\u03c6\u03b5\u03c5\u03c7\u03b8\u03bf\u03cd\u03bd \u03c3\u03c6\u03ac\u03bb\u03bc\u03b1\u03c4\u03b1 \u03b1\u03bd\u03c4\u03b9\u03c3\u03c4\u03bf\u03af\u03c7\u03b9\u03c3\u03b7\u03c2. \u03a3\u03b5 \u03c0\u03b5\u03c1\u03af\u03c0\u03c4\u03c9\u03c3\u03b7 \u03b1\u03bc\u03c6\u03b9\u03b2\u03bf\u03bb\u03af\u03b1\u03c2, \u03c3\u03c5\u03bc\u03b2\u03bf\u03c5\u03bb\u03b5\u03c5\u03c4\u03b5\u03af\u03c4\u03b5 \u03c4\u03b1 \u03c6\u03cd\u03bb\u03bb\u03b1 \u03c0\u03c1\u03bf\u03b4\u03b9\u03b1\u03b3\u03c1\u03b1\u03c6\u03ce\u03bd \u03c4\u03c9\u03bd \u03bc\u03b5\u03c4\u03b1\u03c4\u03c1\u03bf\u03c0\u03ad\u03c9\u03bd \u03c3\u03b1\u03c2 \u03ba\u03b1\u03b9 \u03c4\u03b1 \u03bf\u03b4\u03b7\u03b3\u03ac \u03c1\u03cd\u03b8\u03bc\u03b9\u03c3\u03b7\u03c2 \u03c4\u03c9\u03bd \u03b5\u03bd\u03b5\u03c1\u03b3\u03ce\u03bd \u03c3\u03c5\u03c3\u03ba\u03b5\u03c5\u03ce\u03bd.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" >V\u00e9ase tambi\u00e9n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/erbium-doped-fiber-amplifier-optical-networks\/\">\u039a\u03b1\u03c4\u03b1\u03bd\u03cc\u03b7\u03c3\u03b7 \u03c4\u03bf\u03c5 \u03c1\u03cc\u03bb\u03bf\u03c5 \u03c4\u03bf\u03c5 EDFA \u03c3\u03c4\u03b1 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ac \u03b4\u03af\u03ba\u03c4\u03c5\u03b1<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/how-optical-transceivers-transmit-data\/\">\u0397 \u03b4\u03b9\u03b1\u03b4\u03b9\u03ba\u03b1\u03c3\u03af\u03b1 \u03bc\u03b5\u03c4\u03ac\u03b4\u03bf\u03c3\u03b7\u03c2 \u03b4\u03b5\u03b4\u03bf\u03bc\u03ad\u03bd\u03c9\u03bd \u03bc\u03b5 \u03c7\u03c1\u03ae\u03c3\u03b7 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03bc\u03b5\u03c4\u03b1\u03c4\u03c1\u03bf\u03c0\u03ad\u03c9\u03bd<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/filter-fwdm-optical-networks-applications\/\">\u0395\u03be\u03b5\u03c1\u03b5\u03cd\u03bd\u03b7\u03c3\u03b7 \u03c4\u03c9\u03bd \u03c6\u03af\u03bb\u03c4\u03c1\u03c9\u03bd FWDM \u03ba\u03b1\u03b9 \u03c4\u03b7\u03c2 \u03b5\u03c0\u03af\u03b4\u03c1\u03b1\u03c3\u03ae\u03c2 \u03c4\u03bf\u03c5\u03c2 \u03c3\u03c4\u03b1 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ac \u03b4\u03af\u03ba\u03c4\u03c5\u03b1<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/optical-transceivers-vs-fiber-converters\/\">\u03a3\u03cd\u03b3\u03ba\u03c1\u03b9\u03c3\u03b7 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03bc\u03b5\u03c4\u03b1\u03c4\u03c1\u03bf\u03c0\u03ad\u03c9\u03bd \u03ba\u03b1\u03b9 \u03bc\u03b5\u03c4\u03b1\u03c4\u03c1\u03bf\u03c0\u03ad\u03c9\u03bd \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03bc\u03ad\u03c3\u03c9\u03bd<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/common-fiber-connector-types-optical-transceivers\/\">\u0394\u03b7\u03bc\u03bf\u03c6\u03b9\u03bb\u03b5\u03af\u03c2 \u03c0\u03b1\u03c1\u03b1\u03bb\u03bb\u03b1\u03b3\u03ad\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03c3\u03c5\u03bd\u03b4\u03b5\u03c4\u03ae\u03c1\u03c9\u03bd \u03c0\u03bf\u03c5 \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03bf\u03cd\u03bd\u03c4\u03b1\u03b9 \u03c3\u03b5 \u03bf\u03c0\u03c4\u03b9\u03ba\u03bf\u03cd\u03c2 \u03bc\u03b5\u03c4\u03b1\u03c4\u03c1\u03bf\u03c0\u03b5\u03af\u03c2<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>\u0397 FEC (\u03b4\u03b9\u03cc\u03c1\u03b8\u03c9\u03c3\u03b7 \u03c3\u03c6\u03b1\u03bb\u03bc\u03ac\u03c4\u03c9\u03bd \u03c0\u03c1\u03bf\u03c2 \u03c4\u03b1 \u03b5\u03bc\u03c0\u03c1\u03cc\u03c2) \u03c3\u03c4\u03b9\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u03b5\u03c0\u03b9\u03ba\u03bf\u03b9\u03bd\u03c9\u03bd\u03af\u03b5\u03c2 \u03c0\u03c1\u03bf\u03c3\u03b8\u03ad\u03c4\u03b5\u03b9 \u03c0\u03b5\u03c1\u03b9\u03c4\u03c4\u03cc\u03c4\u03b7\u03c4\u03b1 \u03b3\u03b9\u03b1 \u03c4\u03b7\u03bd \u03b1\u03bd\u03af\u03c7\u03bd\u03b5\u03c5\u03c3\u03b7 \u03ba\u03b1\u03b9 \u03c4\u03b7 \u03b4\u03b9\u03cc\u03c1\u03b8\u03c9\u03c3\u03b7 \u03c3\u03c6\u03b1\u03bb\u03bc\u03ac\u03c4\u03c9\u03bd, \u03b4\u03b9\u03b1\u03c3\u03c6\u03b1\u03bb\u03af\u03b6\u03bf\u03bd\u03c4\u03b1\u03c2 \u03b1\u03be\u03b9\u03cc\u03c0\u03b9\u03c3\u03c4\u03b7 \u03ba\u03b1\u03b9 \u03c5\u03c8\u03b7\u03bb\u03ae\u03c2 \u03c4\u03b1\u03c7\u03cd\u03c4\u03b7\u03c4\u03b1\u03c2 \u03bc\u03b5\u03c4\u03ac\u03b4\u03bf\u03c3\u03b7 \u03b4\u03b5\u03b4\u03bf\u03bc\u03ad\u03bd\u03c9\u03bd.<\/p>","protected":false},"author":1,"featured_media":5576,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[26],"class_list":["post-5577","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5577","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=5577"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5577\/revisions"}],"predecessor-version":[{"id":11284,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5577\/revisions\/11284"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/5576"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=5577"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=5577"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=5577"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}