{"id":5227,"date":"2025-09-04T00:00:00","date_gmt":"2025-09-04T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/1310nm-optical-module-applications-performance-comparison\/"},"modified":"2026-06-22T07:46:57","modified_gmt":"2026-06-22T07:46:57","slug":"1310nm-optical-module-applications-performance-comparison","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/1310nm-optical-module-applications-performance-comparison","title":{"rendered":"Todo lo que necesita saber sobre los m\u00f3dulos \u00f3pticos de 1310 nm"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33cd6eb25ae848029df1e4ff2505c1f4.webp\" alt=\"Everything You Need to Know About 1310nm Optical Modules\" class=\"wp-image-5225\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33cd6eb25ae848029df1e4ff2505c1f4.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33cd6eb25ae848029df1e4ff2505c1f4-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33cd6eb25ae848029df1e4ff2505c1f4-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33cd6eb25ae848029df1e4ff2505c1f4-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/33cd6eb25ae848029df1e4ff2505c1f4-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476100.htm\">M\u00f3dulo \u00f3ptico de 1310 nm<\/a> le permite mover datos de forma eficiente a trav\u00e9s de redes de comunicaci\u00f3n por fibra \u00f3ptica. Como parte de la banda O (1260\u20131360 nm), equilibra una baja dispersi\u00f3n, un rendimiento estable y una eficiencia de costos. Por ello, se adopta ampliamente en centros de datos, redes troncales empresariales y redes de acceso metropolitano. En este art\u00edculo, exploramos las caracter\u00edsticas clave, las aplicaciones comunes y las comparaciones importantes relacionadas con los m\u00f3dulos \u00f3pticos de 1310 nm.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 284px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"284\"><p>Aplicaci\u00f3n\/Industria<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Descripci\u00f3n<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"284\"><p>Redes de \u00e1rea metropolitana (MAN)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Se utilizan para enlaces de distancia media en redes urbanas.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"284\"><p>Redes universitarias<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Proporcionan conexiones estables en escuelas y universidades.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"284\"><p>\u00c1reas urbanas y suburbanas<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Apoyan una comunicaci\u00f3n r\u00e1pida y eficiente entre barrios.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando necesita un rendimiento fiable, un <a target=\"_blank\" href=\"https:\/\/www.l-p.com\/buy-1310nm_optical_transceiver.htm\">Transceptor \u00f3ptico LINK-PP de 1310 nm<\/a> le ofrece una opci\u00f3n de confianza para su red.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Conclusiones clave<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Los m\u00f3dulos \u00f3pticos de 1310 nm son esenciales para la transmisi\u00f3n eficiente de datos en redes de fibra \u00f3ptica, especialmente para distancias medias.<\/p><\/li><li><p>Estos m\u00f3dulos ofrecen bajas p\u00e9rdidas de se\u00f1al y m\u00ednima distorsi\u00f3n, lo que los hace ideales para aplicaciones en redes de \u00e1rea metropolitana y entornos universitarios.<\/p><\/li><li><p>Elegir el tipo adecuado de fibra, normalmente monomodo, mejora el rendimiento de los m\u00f3dulos de 1310 nm, permitiendo mayores distancias de transmisi\u00f3n.<\/p><\/li><li><p>Los l\u00e1seres de 1310 nm admiten diversas velocidades de datos, desde 1 Gbps hasta 100 Gbps, ofreciendo flexibilidad para distintas necesidades de red.<\/p><\/li><li><p>Al <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">seleccionar un m\u00f3dulo<\/a>, considere factores como el cumplimiento de est\u00e1ndares, el rango de temperatura y la distancia de transmisi\u00f3n para garantizar compatibilidad y fiabilidad.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >Caracter\u00edsticas clave de los m\u00f3dulos \u00f3pticos de 1310 nm<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">Los m\u00f3dulos \u00f3pticos de 1310 nm<\/a> son una de las soluciones m\u00e1s utilizadas en comunicaciones \u00f3pticas, especialmente para transmisi\u00f3n en fibra monomodo (SMF) a distancias cortas y medias. Situada entre los 850 nm (t\u00edpicamente para alcance corto en multimodo) y los 1550 nm (t\u00edpicamente para larga distancia), la longitud de onda de 1310 nm ofrece un equilibrio \u00f3ptimo entre costo, alcance y rendimiento.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Longitud de onda central<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Valor t\u00edpico: 1310 nm (\u00b120 nm, seg\u00fan el tipo de m\u00f3dulo)<\/p><\/li><li><p>Pertenece a la <strong>Banda O<\/strong> (Banda original: 1260\u20131360 nm), donde la dispersi\u00f3n crom\u00e1tica es m\u00ednima, lo que la hace adecuada para transmisi\u00f3n a distancia media.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Alcance de transmisi\u00f3n<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>LR<\/strong> (Alcance largo): hasta 10\/40 km sobre fibra monomodo (SMF)<\/p><\/li><li><p><strong>LX<\/strong> (Longitud de onda larga): se utiliza frecuentemente en Gigabit Ethernet, soportando hasta 10 km sobre SMF; con cables de acondicionamiento de modo tambi\u00e9n puede funcionar sobre fibra multimodo (MMF) a distancias m\u00e1s cortas.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Caracter\u00edsticas espectrales<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Tipo de l\u00e1ser: FP (Fabry\u2013Perot) o DFB (Distributed Feedback), seg\u00fan la velocidad de datos y el alcance<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/fabry-perot-laser-diodes-in-optical-modules\/\">L\u00e1ser FP<\/a>: Se utiliza en m\u00f3dulos de menor costo (1G\/2,5G), adecuados para distancias cortas a medias<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/dfb-laser-definition\/\">L\u00e1ser DFB<\/a>: Proporciona un ancho de l\u00ednea espectral m\u00e1s estrecho, requerido para velocidades superiores (10G y superiores) y mayores distancias<\/p><\/li><li><p>Ancho espectral (l\u00e1ser FP): t\u00edpicamente 30\u201360 nm (FWHM)<\/p><\/li><li><p>Ancho espectral (l\u00e1ser DFB): t\u00edpicamente &lt;1 nm<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Velocidades de datos y est\u00e1ndares compatibles<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/478919.htm\">SFP de 1,25 G (1000BASE-LX)<\/a>: hasta 10 km sobre SMF<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475605.htm\">SFP+ LR de 10 G<\/a>: l\u00e1ser DFB de 1310 nm, alcance hasta 10 km<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/478240.htm\">SFP28 LR de 25 G<\/a>: 1310 nm, alcance hasta 20 km<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482496.htm\">100G QSFP28 LR4<\/a>: utiliza 4 canales de 25 G a 1310 nm con multiplexaci\u00f3n por divisi\u00f3n de longitud de onda (WDM), soporta 10 km sobre SMF<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Par\u00e1metros \u00f3pticos (valores t\u00edpicos)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Potencia \u00f3ptica de transmisi\u00f3n: -8 dBm a +0,5 dBm (10G LR)<\/p><\/li><li><p>Sensibilidad del receptor: aproximadamente -14,4 dBm (10G LR, BER \u2264 10\u207b\u00b9\u00b2)<\/p><\/li><li><p>Relaci\u00f3n de extinci\u00f3n: \u2265 3,5 dB (10G LR)<\/p><\/li><li><p>Temperatura de operaci\u00f3n: Comercial: 0 \u00b0C a +70 \u00b0C; Industrial: -40 \u00b0C a +85 \u00b0C<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >Ventajas y limitaciones<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/508ef34714d24062a36f69e0c75c0e48.webp\" alt=\"1310nm Optical Modules\" class=\"wp-image-5226\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/508ef34714d24062a36f69e0c75c0e48.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/508ef34714d24062a36f69e0c75c0e48-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/508ef34714d24062a36f69e0c75c0e48-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/508ef34714d24062a36f69e0c75c0e48-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/508ef34714d24062a36f69e0c75c0e48-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Beneficios clave de <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/buy-1310nm_optical_transceiver.htm\">los m\u00f3dulos de 1310 nm<\/a><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Baja dispersi\u00f3n crom\u00e1tica:<\/strong> Al operar en la banda O, los m\u00f3dulos de 1310 nm minimizan la distorsi\u00f3n de la se\u00f1al a distancias medias.<\/p><\/li><li><p><strong>Rentable:<\/strong> M\u00e1s econ\u00f3micos que las soluciones de 1550 nm para aplicaciones de \u226410 km.<\/p><\/li><li><p><strong>Amplia compatibilidad:<\/strong> Soportados por redes Ethernet, SONET\/SDH, OTN y de acceso frontal\/mid-haul 5G.<\/p><\/li><li><p><strong>M\u00faltiples factores de forma:<\/strong> Disponibles como SFP, SFP+, SFP28, QSFP28, CFP, entre otros.<\/p><\/li><li><p><strong>Velocidades flexibles:<\/strong> Opciones desde 1G hasta 100G, lo que facilita las actualizaciones.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc <em>Ideal para redes que requieren un equilibrio entre alcance, costo y fiabilidad.<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 176px;\"\/><col style=\"width: 491px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"176\"><p>\u039f\u03c6\u03ad\u03bb\u03b7<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"491\"><p>Descripci\u00f3n<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"176\"><p>Baja dispersi\u00f3n<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"491\"><p>Mantiene la calidad de la se\u00f1al durante varios kil\u00f3metros<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"176\"><p>Rentabilidad<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"491\"><p>Reduce los gastos de despliegue de la red<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"176\"><p>Velocidades vers\u00e1tiles<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"491\"><p>Soporta una variedad de est\u00e1ndares Ethernet<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Limitaciones de los m\u00f3dulos \u00f3pticos de 1310 nm<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Restricci\u00f3n de distancia:<\/strong> El alcance est\u00e1ndar es de hasta 10 km. Los enlaces m\u00e1s largos requieren \u00f3ptica de 1550 nm.<\/p><\/li><li><p><strong>Mayor atenuaci\u00f3n:<\/strong> P\u00e9rdida de se\u00f1al ligeramente mayor en comparaci\u00f3n con los m\u00f3dulos de 1550 nm, lo que afecta el rendimiento en transmisi\u00f3n de larga distancia.<\/p><\/li><li><p><strong>Orientado a fibra monomodo:<\/strong> Dise\u00f1ado principalmente para fibra monomodo (SMF); su uso con fibra multimodo (MMF) requiere cables de acondicionamiento de modo.<\/p><\/li><li><p><strong>No apto para DWDM:<\/strong> Los m\u00f3dulos de 1310 nm no admiten la multiplexaci\u00f3n densa por divisi\u00f3n de longitud de onda (DWDM).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc <em>Para redes troncales de larga distancia o DWDM, las soluciones de 1550 nm son m\u00e1s adecuadas.<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Aplicaciones del m\u00f3dulo \u00f3ptico de 1310 nm<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los m\u00f3dulos \u00f3pticos de 1310 nm se utilizan ampliamente en <strong>centros de datos, redes troncales empresariales, redes universitarias, telecomunicaciones y entornos de radiodifusi\u00f3n<\/strong>. Su equilibrio entre rendimiento, eficiencia de costos y alcance los convierte en una opci\u00f3n popular para la transmisi\u00f3n a distancia media sobre fibra monomodo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Centros de datos y <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/data-center-interconnect-definition-benefits-and-role-of-optical-modules\/\">DCI<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En los centros de datos, los m\u00f3dulos de 1310 nm admiten <strong>interconexiones de alta velocidad de hasta 10 km<\/strong>, conectando switches, servidores y sistemas de almacenamiento entre edificios o campus. Se implementan com\u00fanmente en <strong>Ethernet de 10G, 25G y 100G<\/strong> .<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Est\u00e1ndar<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Longitud de onda<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Distancia<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Tipo de fibra<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475605.htm\">10GBASE-LR<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Monomodo<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/478240.htm\">25GBASE-LR<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>20 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Monomodo<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482496.htm\">100GBASE-LR4<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Monomodo<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Redes empresariales y universitarias<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los m\u00f3dulos de 1310 nm tambi\u00e9n son esenciales en <strong>redes troncales empresariales<\/strong> \u03ba\u03b1\u03b9 <strong>redes de campus<\/strong>, como grandes edificios de oficinas, hospitales y universidades. Proporcionan:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Alcance estable de 10 km sobre fibra monomodo<\/p><\/li><li><p>Menor dispersi\u00f3n crom\u00e1tica en comparaci\u00f3n con longitudes de onda m\u00e1s cortas (por ejemplo, 850 nm)<\/p><\/li><li><p>Conectividad de alta velocidad entre los switches principales y de distribuci\u00f3n<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc <em>Son ideales para crear redes robustas a escala de campus con p\u00e9rdida de se\u00f1al m\u00ednima.<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Telecomunicaciones y radiodifusi\u00f3n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En telecomunicaciones y radiodifusi\u00f3n, las \u00f3pticas de 1310 nm respaldan <strong>acceso metropolitano, backhaul m\u00f3vil y transporte de video<\/strong>. Sus ventajas incluyen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Cumplimiento de los est\u00e1ndares de telecomunicaciones para interoperabilidad<\/p><\/li><li><p>Transmisi\u00f3n estable para servicios de video y voz<\/p><\/li><li><p>Conectividad de respaldo de alcance medio en zonas urbanas y suburbanas<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc <em>Los operadores implementan \u00f3pticas de 1310 nm en <\/em><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/5g-networks-optical-modules\/\"><em>Fronthaul\/midhaul 5G<\/em><\/a><em>, enlaces metropolitanos y estudios de radiodifusi\u00f3n para un rendimiento fiable.<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Comparaci\u00f3n entre m\u00f3dulos \u00f3pticos de 1310 nm y 1550 nm<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Distancia y atenuaci\u00f3n<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>1310 nm<\/strong> son ideales para <strong>enlaces de alcance medio hasta 10 km<\/strong>. Proporcionan un rendimiento fiable en centros de datos, redes troncales de campus y redes de acceso metropolitano, con una atenuaci\u00f3n baja pero ligeramente mayor que la de 1550 nm.<\/p><\/li><li><p><strong>1<\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/buy-1550nm_optical_modules.htm\"><strong>M\u00f3dulos de 1550 nm<\/strong> <\/a>sobresalen en <strong>transmisi\u00f3n de larga distancia (40 km\u2013100 km o m\u00e1s)<\/strong>, gracias a su <strong>atenuaci\u00f3n muy baja<\/strong>. Se utilizan ampliamente en redes troncales y enlaces interurbanos donde debe preservarse la integridad de la se\u00f1al durante largas distancias.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n se muestra una tabla con las principales diferencias:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 140px;\"\/><col style=\"width: 156px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"140\"><p>Longitud de onda<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"156\"><p>Alcance t\u00edpico<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Atenuaci\u00f3n<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Caso de uso \u00f3ptimo<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"140\"><p><strong>1310 nm<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"156\"><p>Hasta 10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Baja (~0,35 dB\/km)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Metropolitana, campus, interconexi\u00f3n de centros de datos (DCI)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"140\"><p><strong>1550 nm<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"156\"><p>40\u2013100 km o m\u00e1s<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Muy baja (~0,2 dB\/km)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Red troncal, larga distancia<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Costo y casos de uso<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Los m\u00f3dulos de 1310 nm<\/strong> are <strong>son m\u00e1s rentables<\/strong>, lo que los convierte en el est\u00e1ndar para transmisi\u00f3n de corta a media distancia en <strong>centros de datos, redes troncales empresariales y redes metropolitanas<\/strong>.<\/p><\/li><li><p><strong>Los m\u00f3dulos de 1550 nm<\/strong> are <strong>son m\u00e1s costosos<\/strong>, pero admiten <strong>transmisi\u00f3n de larga distancia y DWDM<\/strong>, por lo que son la opci\u00f3n preferida para <strong>redes troncales de telecomunicaciones y redes \u00f3pticas de larga distancia<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 <strong>Gu\u00eda r\u00e1pida:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Elegir <strong>1310 nm<\/strong> \u03b3\u03b9\u03b1 <strong>enlaces rentables \u226410 km<\/strong>.<\/p><\/li><li><p>Elegir <strong>1550 nm<\/strong> \u03b3\u03b9\u03b1 <strong>aplicaciones de larga distancia (40 km o m\u00e1s) y DWDM<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >Selecci\u00f3n del m\u00f3dulo adecuado<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Al seleccionar un m\u00f3dulo \u00f3ptico de 1310 nm, considere:<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" >Distancia de transmisi\u00f3n:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>\u226410 km: los m\u00f3dulos LR de 1310 nm son \u00f3ptimos<\/p><\/li><li><p>\u226540 km: considere en su lugar m\u00f3dulos ER\/ZR de 1550 nm<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >Velocidad de datos:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Ajuste el m\u00f3dulo a la velocidad de la red (1G, 10G, 25G, 100G)<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >Tipo de l\u00e1ser:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">FP para 1G\/2,5G, DFB para 10G y superiores<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >Entorno:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Elija versiones de grado industrial (-40 \u00b0C a 85 \u00b0C) para uso exterior o en telecomunicaciones<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" >Compatibilidad:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Aseg\u00farese de que el m\u00f3dulo funcione con switches\/routers de Cisco, Huawei, Juniper, etc.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udc49 Explore la selecci\u00f3n de m\u00f3dulos \u00f3pticos de 1310 nm de LINK-PP: <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/buy-1310nm_optical_transceiver.htm\">LINK-PP Transceptores \u00d3pticos<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >FAQ<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1l es la distancia m\u00e1xima que puede alcanzar con un m\u00f3dulo \u00f3ptico de 1310 nm?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Puede alcanzar hasta 10 kil\u00f3metros con m\u00f3dulos est\u00e1ndar de 1310 nm sobre fibra monomodo. Algunos modelos extendidos admiten hasta 40 kil\u00f3metros. Siempre verifique las especificaciones de su m\u00f3dulo para conocer la distancia exacta.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfPuede usar m\u00f3dulos \u00f3pticos de 1310 nm con fibra multimodo?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Por lo general, los m\u00f3dulos de 1310 nm se usan con fibra monomodo. Algunos m\u00f3dulos de 1G funcionan con fibra multimodo si se a\u00f1ade un cable de acondicionamiento de modo. Para obtener los mejores resultados, elija fibra monomodo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 est\u00e1ndares Ethernet admiten los m\u00f3dulos de 1310 nm?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Encuentre m\u00f3dulos de 1310 nm que admitan los est\u00e1ndares Ethernet de 1G, 10G, 25G y 100G. Estos m\u00f3dulos funcionan bien en redes de campus, metropolitanas y de centros de datos. Verifique la compatibilidad con su dispositivo antes de la instalaci\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfC\u00f3mo supervisa el rendimiento de un m\u00f3dulo \u00f3ptico de 1310 nm?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Usted utiliza <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/ddm-dom-in-optical-transceivers\/\">Monitoreo digital de diagn\u00f3sticos (DDM)<\/a> para supervisar temperatura, voltaje y potencia \u00f3ptica. La funci\u00f3n DDM le ayuda a mantener una operaci\u00f3n estable y detectar r\u00e1pidamente problemas. La mayor\u00eda de los m\u00f3dulos modernos incluyen esta caracter\u00edstica.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >V\u00e9ase tambi\u00e9n<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/buy-1310nm-optical-transceivers-online\/?utm_source=chatgpt.com\">Compre transceptores \u00f3pticos de 1310 nm en l\u00ednea<\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/applications-of-1310nm-optical-transceivers\/?utm_source=chatgpt.com\">Aplicaciones de los transceptores \u00f3pticos de 1310 nm<\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/dfb-laser-definition\/?utm_source=chatgpt.com\">Definici\u00f3n del l\u00e1ser DFB<\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/fabry-perot-laser-diodes-in-optical-modules\/?utm_source=chatgpt.com\">L\u00e1seres de diodos Fabry-Perot en m\u00f3dulos \u00f3pticos<\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/ddm-dom-in-optical-transceivers\/?utm_source=chatgpt.com\">DDM\/DOM en transceptores \u00f3pticos<\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/5g-networks-optical-modules\/?utm_source=chatgpt.com\">M\u00f3dulos \u00f3pticos en redes 5G<\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/data-center-interconnect-definition-benefits-and-role-of-optical-modules\/?utm_source=chatgpt.com\">Interconexi\u00f3n de centros de datos: definici\u00f3n, beneficios y papel de los m\u00f3dulos \u00f3pticos<\/a><\/p><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>El m\u00f3dulo \u00f3ptico de 1310 nm ofrece una transmisi\u00f3n de datos fiable y rentable para redes metropolitanas, de campus y empresariales. Compare el rendimiento, el alcance y los casos de uso.<\/p>","protected":false},"author":1,"featured_media":5225,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[26],"class_list":["post-5227","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5227","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=5227"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5227\/revisions"}],"predecessor-version":[{"id":11184,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5227\/revisions\/11184"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/5225"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=5227"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=5227"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=5227"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}