{"id":5125,"date":"2025-09-10T00:00:00","date_gmt":"2025-09-10T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/qsfp-40g-fr4-meaning-benefits-network-future-proof\/"},"modified":"2026-06-22T07:28:49","modified_gmt":"2026-06-22T07:28:49","slug":"qsfp-40g-fr4-meaning-benefits-network-future-proof","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/qsfp-40g-fr4-meaning-benefits-network-future-proof","title":{"rendered":"\u0395\u03be\u03ae\u03b3\u03b7\u03c3\u03b7 \u03c4\u03bf\u03c5 QSFP+ 40G FR4: \u039f \u03bf\u03c1\u03b9\u03c3\u03c4\u03b9\u03ba\u03cc\u03c2 \u03c3\u03b1\u03c2 \u03bf\u03b4\u03b7\u03b3\u03cc\u03c2 \u03b3\u03b9\u03b1 \u03c0\u03b1\u03c1\u03ac\u03bb\u03bb\u03b7\u03bb\u03b7 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ae \u03c4\u03b5\u03c7\u03bd\u03bf\u03bb\u03bf\u03b3\u03af\u03b1 4x10G"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4.webp\" alt=\"What is qsfp+ 40g FR4 and why does it matter\" class=\"wp-image-5123\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8e33a45f15b14fecb912b5b290bdc1b4-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">En el mundo de alta velocidad de los centros de datos y las redes empresariales, la demanda de ancho de banda es cada vez mayor. Elegir el transceptor \u00f3ptico adecuado es fundamental para construir una infraestructura de red escalable, eficiente y rentable. Entre las diversas opciones disponibles, el<br> <strong>QSFP+ 40G FR4<br><\/strong> destaca como una soluci\u00f3n clave para lograr conectividad de 40 G.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pero \u00bfqu\u00e9 es exactamente y por qu\u00e9 es tan importante? Esta gu\u00eda integral explicar\u00e1 la tecnolog\u00eda, las especificaciones y las ventajas del<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482435.htm\"><strong>transceptor QSFP+ 40G FR4<br><\/strong><\/a>, un componente esencial para aplicaciones modernas de<br> <strong>Ethernet 40G<\/strong> y canal de fibra.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Desglose del nombre: QSFP+ 40G FR4<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Comencemos descifrando el nombre mismo, que revela sus caracter\u00edsticas fundamentales:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>\u03a0\u03b1\u03c1\u03ac\u03b3\u03c9\u03b3\u03bf \u03a0\u03b1\u03c1\u03ac\u03b3\u03c9\u03b3\u03bf<\/strong>: Significa<br> <strong>Cu\u00e1druple (Q) factor de forma peque\u00f1o extra\u00edble Plus<br><\/strong>. Esto significa que es un m\u00f3dulo compacto y extra\u00edble en caliente capaz de soportar<br> <strong>cuatro canales independientes<br><\/strong> de transmisi\u00f3n y recepci\u00f3n de datos. Es una evoluci\u00f3n del factor de forma SFP+, dise\u00f1ado para mayores densidades y velocidades.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>40G<\/strong>: Indica la velocidad de datos total del m\u00f3dulo, que es<br> <strong>40 gigabits por segundo<br><\/strong>. Con cuatro canales, cada uno opera a 10 Gbps.<br>.<\/p><\/li><li><p style=\"margin: 0px 0px 8px;\"><strong>FR<\/strong>: Significa<br> <strong>Multiplexaci\u00f3n por divisi\u00f3n de longitud de onda gruesa de 4 longitudes de onda<br> <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/what-is-cwdm-understanding-coarse-wavelength-division-multiplexing\/\"><strong>(CWDM)<\/strong><\/a>. Utiliza cuatro se\u00f1ales l\u00e1ser individuales en longitudes de onda espec\u00edficas (1271 nm, 1291 nm, 1311 nm y 1331 nm) transmitidas sobre una<br><strong> fibra monomodo est\u00e1ndar <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>4<\/strong>: Representa los<br> <strong>4 canales<br><\/strong> de 10 G, que se multiplexan para crear un enlace \u00fanico de 40 G.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f \u00bfC\u00f3mo funciona un transceptor QSFP+ 40G FR4?<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La magia de FR4 radica en su uso de la tecnolog\u00eda CWDM. Es fundamental comprender que un<br> <strong>\u00fanico m\u00f3dulo QSFP+ 40G FR4 es unidireccional<br><\/strong>: o bien transmite o bien recibe la se\u00f1al multiplexada. Un enlace completo requiere dos m\u00f3dulos: uno en cada extremo del enlace de fibra.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n se presenta un desglose simplificado del proceso de comunicaci\u00f3n entre dos conmutadores:<br><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px 0px 8px;\"><strong>En el extremo transmisor (Conmutador A):<br><\/strong><\/p><ul><li><p style=\"margin: 0px;\">El transceptor (<br><strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482435.htm\"><strong>LQ-CW40-FR4C<br><\/strong><\/a>) recibe cuatro carriles el\u00e9ctricos de 10 G procedentes del Conmutador A.<br>.<\/p><\/li><li><p style=\"margin: 0px;\">Cuatro l\u00e1seres distintos de<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/dfb-laser-definition\/\"><strong>retroalimentaci\u00f3n distribuida (DFB)<br><\/strong><\/a> convierten cada se\u00f1al el\u00e9ctrica en una longitud de onda \u00f3ptica espec\u00edfica (1271 nm, 1291 nm, 1311 nm y 1331 nm).<\/p><\/li><li><p style=\"margin: 0px;\">Un multiplexor (MUX) integrado combina estas cuatro se\u00f1ales \u00f3pticas en un solo cable de fibra monomodo (SMF) para su transmisi\u00f3n.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 8px;\"><strong>Transmisi\u00f3n por fibra:<\/strong><\/p><ul><li><p style=\"margin: 0px;\">La se\u00f1al combinada CWDM viaja a trav\u00e9s del cable de fibra \u00f3ptica monomodo (un cable de transmisi\u00f3n).<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 8px;\"><strong>En el extremo receptor (conmutador B):<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Otro <strong>LINK-PP LQ-CW40-FR4C<\/strong> m\u00f3dulo recibe la se\u00f1al combinada en un cable de fibra separado.<\/p><\/li><li><p style=\"margin: 0px;\">Un demultiplexor (DEMUX) integrado separa las cuatro longitudes de onda entrantes.<\/p><\/li><li><p style=\"margin: 0px;\">Los fotodetectores convierten cada longitud de onda \u00f3ptica nuevamente en una se\u00f1al el\u00e9ctrica, entregando cuatro canales de 10 G al conmutador B.<\/p><\/li><\/ul><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Este proceso ocurre en sentido inverso para la comunicaci\u00f3n desde el conmutador B al conmutador A, lo que requiere un segundo par de fibras. Por lo tanto, un enlace <strong>d\u00faplex completo de 40 G requiere dos cables de fibra monomodo (SMF)<\/strong> (uno para Tx\/Rx y otro para Rx\/Tx).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f QSFP+ 40G FR4 frente a SR4: tabla comparativa r\u00e1pida<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Elegir el transceptor adecuado depende del tipo de fibra y los requisitos de distancia. El principal competidor del FR4 es el <strong>QSFP+ 40G SR4<br><\/strong>, dise\u00f1ado para fibra multimodo.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Caracter\u00edstica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482435.htm\"><strong>QSFP+ 40G FR4<br><\/strong><\/a><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482749.htm\"><strong>QSFP+ 40G SR4<br><\/strong><\/a><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tipo de fibra<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Fibra monomodo (SMF)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra multimodo (MMF \u2013 OM3\/OM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u0391\u03c0\u03cc\u03c3\u03c4\u03b1\u03c3\u03b7<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hasta <strong>2 kil\u00f3metros<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hasta 100 m (OM3) \/ 150 m (OM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Tecnolog\u00eda<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>CWDM (4 longitudes de onda en 1 fibra)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u00d3ptica paralela (4 fibras independientes)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u03a3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Conector d\u00faplex LC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Conector MTP\/MPO de 12 fibras<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Caso de uso principal<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de larga distancia en centros de datos, interconexi\u00f3n entre centros de datos (DCI)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de corta distancia dentro de un rack o sala de servidores<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Costo de la fibra<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>M\u00e1s alto (SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>M\u00e1s bajo (MMF)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Densidad de cableado<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>\u03a5\u03c8\u03b7\u03bb\u03cc<\/strong> (Utiliza solo 2 fibras por enlace)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>M\u00e1s baja (Requiere 8 fibras por enlace)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Conclusi\u00f3n clave:<\/strong> \u03a7\u03c1\u03ae\u03c3\u03b7 <strong>SR4<\/strong> para recorridos cortos y rentables dentro de su centro de datos. Use <strong>FR4<\/strong> cuando necesite cubrir distancias m\u00e1s largas (hasta 2 km) entre edificios o en un campus extenso, o cuando desee conservar valiosos cables de fibra.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Aplicaciones clave y beneficios de los m\u00f3dulos 40G FR4<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u03a4\u03bf \/ \u0397 \/ \u039f <strong>transceptor QSFP+ 40G FR4<br><\/strong> es una soluci\u00f3n vers\u00e1til para arquitectos de redes modernas.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>\u0394\u03b9\u03b1\u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7 \u0394\u03b5\u03c1\u03bc\u03b5\u03bd\u03b5\u03af\u03c9\u03bd \u0394\u03b5\u03b4\u03bf\u03bc\u03ad\u03bd\u03c9\u03bd (DCI):<\/strong> Ideal para conectar dos centros de datos ubicados a hasta 2 km de distancia.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Enlaces de conmutadores 40G de alta densidad:<\/strong> Perfecto para crear enlaces troncales de alta velocidad entre conmutadores en distintas zonas de un edificio o campus.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Maximizaci\u00f3n de la infraestructura de fibra:<\/strong> Su capacidad para transportar 40 G sobre tan solo dos cables de fibra monomodo lo hace extremadamente eficiente, retrasando la necesidad de instalaciones costosas de nueva fibra.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Integraci\u00f3n con sistemas CWDM:<\/strong> Puede integrarse f\u00e1cilmente en la infraestructura existente de CWDM para un dise\u00f1o de red flexible.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f \u00bfBusca una soluci\u00f3n fiable de 40G FR4? Conozca LINK-PP<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2.webp\" alt=\"QSFP+ 40G FR4 optical transceiver\" class=\"wp-image-5124\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/7a9b7841c49a4c24b14e5016ad88b1a2-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando el rendimiento y el tiempo de actividad de la red son cr\u00edticos, elegir un transceptor de alta calidad y compatible es imprescindible. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/page\/aboutus.htm\"><strong>LINK-PP<\/strong><\/a> fabrica una gama de <strong>compatibles con el est\u00e1ndar MSA,<\/strong> transceptores \u00f3pticos conocidos por su fiabilidad, rendimiento y compatibilidad perfecta con los principales switches OEM de Cisco, Juniper, Arista, y m\u00e1s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para sus <strong>necesidades de 40G QSFP+ FR4<\/strong> , le recomendamos lo siguiente:<br\/><strong>LINK-PP LQ-CW40-FR4C<\/strong><br\/>Este m\u00f3dulo se somete a pruebas rigurosas para garantizar su total interoperabilidad y cuenta con una garant\u00eda de por vida, lo que le brinda tranquilidad para sus enlaces de red cr\u00edticos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&gt; &gt; <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/file\/datasheet\/lq-cw40-fr4c.pdf\"><strong>Descubra la hoja t\u00e9cnica del LINK-PP LQ-CW40-FR4C<\/strong><\/a><strong> &lt;&lt;<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Conclusi\u00f3n<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u03a4\u03bf \/ \u0397 \/ \u039f <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482435.htm\"><strong>transceptor QSFP+ 40G FR4<br><\/strong><\/a> es una soluci\u00f3n sofisticada y eficiente para redes de velocidad elevada y alcance medio. Su uso inteligente de la tecnolog\u00eda CWDM sobre fibra monomodo lo convierte en una herramienta indispensable para <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/data-center-interconnect-definition-benefits-and-role-of-optical-modules\/\"><strong>interconexiones entre centros de datos (DCI)<\/strong><\/a>, maximizando los activos de fibra existentes y construyendo estructuras troncales de red escalables.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Al comprender su funci\u00f3n y c\u00f3mo se compara con SR4, puede tomar una decisi\u00f3n informada que optimice tanto el rendimiento como el costo de su implementaci\u00f3n de Ethernet 40G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2699\ufe0f Preguntas frecuentes (FAQ)<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 significa QSFP+ 40G FR4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ve \u201cqsfp+\u201d como un tipo de transceptor. \u201c40g\u201d indica la velocidad, que es de 40 gigabits por segundo. \u201cfr4\u201d significa que utiliza cuatro longitudes de onda sobre fibra monomodo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCon qu\u00e9 dispositivos funciona QSFP+ 40G FR4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Puede usar qsfp+ 40g fr4 en muchos switches y servidores de red. La mayor\u00eda del equipo moderno con puertos QSFP+ admite este transceptor.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1l es la distancia m\u00e1xima para QSFP+ 40G FR4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Puede conectar dispositivos separados hasta 2 kil\u00f3metros. Este alcance funciona bien en centros de datos grandes y edificios de oficinas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 tipo de fibra necesita para QSFP+ 40G FR4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Necesita fibra monomodo. Este tipo de cable le permite enviar datos a largas distancias sin perder calidad.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 diferencia a QSFP+ 40G FR4 de los transceptores anteriores?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Obtiene mayor velocidad, mayor alcance y mejor eficiencia. Su peque\u00f1o tama\u00f1o le ayuda a ahorrar espacio y energ\u00eda en sus bastidores de red.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u03a4\u03bf qsfp+ 40g FR4 \u03c0\u03c1\u03bf\u03c3\u03c6\u03ad\u03c1\u03b5\u03b9 \u03bc\u03b5\u03c4\u03ac\u03b4\u03bf\u03c3\u03b7 \u03b4\u03b5\u03b4\u03bf\u03bc\u03ad\u03bd\u03c9\u03bd \u03c5\u03c8\u03b7\u03bb\u03ae\u03c2 \u03c4\u03b1\u03c7\u03cd\u03c4\u03b7\u03c4\u03b1\u03c2 \u03ba\u03b1\u03b9 \u03bc\u03b5\u03b3\u03ac\u03bb\u03b7\u03c2 \u03b5\u03bc\u03b2\u03ad\u03bb\u03b5\u03b9\u03b1\u03c2 \u03b3\u03b9\u03b1 \u03c3\u03cd\u03b3\u03c7\u03c1\u03bf\u03bd\u03b1 \u03b4\u03af\u03ba\u03c4\u03c5\u03b1, \u03b2\u03b5\u03bb\u03c4\u03b9\u03ce\u03bd\u03bf\u03bd\u03c4\u03b1\u03c2 \u03c4\u03b7\u03bd \u03b1\u03c0\u03cc\u03b4\u03bf\u03c3\u03b7, \u03c4\u03b7\u03bd \u03b1\u03c0\u03bf\u03b4\u03bf\u03c4\u03b9\u03ba\u03cc\u03c4\u03b7\u03c4\u03b1 \u03ba\u03b1\u03b9 \u03c4\u03b7 \u03bc\u03b5\u03bb\u03bb\u03bf\u03bd\u03c4\u03b9\u03ba\u03ae \u03ba\u03bb\u03b9\u03bc\u03ac\u03ba\u03c9\u03c3\u03b7 \u03c3\u03c4\u03b1 \u03ba\u03ad\u03bd\u03c4\u03c1\u03b1 \u03b4\u03b5\u03b4\u03bf\u03bc\u03ad\u03bd\u03c9\u03bd.<\/p>","protected":false},"author":1,"featured_media":5123,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[18],"class_list":["post-5125","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-40g-qsfp-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5125","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=5125"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5125\/revisions"}],"predecessor-version":[{"id":11153,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/5125\/revisions\/11153"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/5123"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=5125"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=5125"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=5125"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}