{"id":4720,"date":"2025-10-14T11:12:00","date_gmt":"2025-10-14T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/difference-between-pse-and-pd-in-poe-networks\/"},"modified":"2026-06-22T09:02:40","modified_gmt":"2026-06-22T09:02:40","slug":"difference-between-pse-and-pd-in-poe-networks","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/difference-between-pse-and-pd-in-poe-networks","title":{"rendered":"PSE \u03ad\u03bd\u03b1\u03bd\u03c4\u03b9 PD \u2014 \u0395\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u03c0\u03b1\u03c1\u03bf\u03c7\u03ae\u03c2 \u03b5\u03bd\u03ad\u03c1\u03b3\u03b5\u03b9\u03b1\u03c2 \u03ad\u03bd\u03b1\u03bd\u03c4\u03b9 \u03c3\u03c5\u03c3\u03ba\u03b5\u03c5\u03ae\u03c2 \u03c0\u03bf\u03c5 \u03c4\u03c1\u03bf\u03c6\u03bf\u03b4\u03bf\u03c4\u03b5\u03af\u03c4\u03b1\u03b9 \u03c3\u03c4\u03b1 \u03b4\u03af\u03ba\u03c4\u03c5\u03b1 PoE"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9.webp\" alt=\"PSE vs. PD in PoE\" class=\"wp-image-4718\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>PSE (Equipo de Suministro de Energ\u00eda)<\/strong> suministra energ\u00eda de corriente continua (CC) mediante el cableado Ethernet; <strong>PD (dispositivo alimentado)<\/strong> la consume. <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/ieee-802-3af-poe-standard-explained\/\"><strong>Normas PoE<\/strong><\/a> (IEEE 802.3af\/at\/bt) definen cu\u00e1nta potencia se puede ofrecer y c\u00f3mo el PSE y el PD detectan y negocian de forma segura la energ\u00eda. Comprender la diferencia entre PSE y PD es fundamental para la selecci\u00f3n correcta de dispositivos, la fiabilidad del sistema, la planificaci\u00f3n t\u00e9rmica y del cableado, y el cumplimiento normativo. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Definiciones claras<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Las redes Ethernet modernas no transportan \u00fanicamente datos: tambi\u00e9n suministran energ\u00eda.<br\/>Esta capacidad, conocida como <strong>Alimentaci\u00f3n a trav\u00e9s de Ethernet (PoE)<\/strong>, permite que dispositivos como puntos de acceso inal\u00e1mbricos, c\u00e1maras IP y tel\u00e9fonos VoIP reciban tanto datos como energ\u00eda de corriente continua (CC) a trav\u00e9s de un \u00fanico cable de pares trenzados.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En el coraz\u00f3n de todo sistema PoE hay dos componentes esenciales:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>PSE (Equipo de Suministro de Energ\u00eda)<\/strong> \u2014 el dispositivo que <em>suministra<\/em> energ\u00eda.<\/p><\/li><li><p><strong>PD (dispositivo alimentado)<\/strong> \u2014 el dispositivo que <em>recibe<\/em> energ\u00eda.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Comprender c\u00f3mo interact\u00faan estos dos componentes es clave para dise\u00f1ar redes PoE eficientes, fiables y conformes a las normas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/poe-pse-power-sourcing-equipment-guide\/\">PSE \u2014 Equipo de suministro de energ\u00eda<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>la PSE<\/strong> es cualquier dispositivo que inyecta energ\u00eda en los pares trenzados Ethernet: conmutadores compatibles con PoE (<strong>extremo del intervalo<\/strong>) o inyectores en l\u00ednea\/<strong>midspan<\/strong>. El PSE se encarga de la detecci\u00f3n, clasificaci\u00f3n y gesti\u00f3n de la asignaci\u00f3n de energ\u00eda por puerto. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La funci\u00f3n del PSE consiste en detectar si un dispositivo conectado es compatible con PoE, determinar sus necesidades de energ\u00eda y suministrar de forma segura la tensi\u00f3n y corriente adecuadas. Los mecanismos de detecci\u00f3n y clasificaci\u00f3n garantizan que los dispositivos no compatibles con PoE nunca reciban energ\u00eda accidentalmente, protegiendo as\u00ed equipos sensibles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tipos comunes de PSE:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>PSE de extremo:<\/strong> Integrado directamente en un puerto de conmutador PoE.<\/p><\/li><li><p><strong>PSE de intermedio:<\/strong> Inyector externo colocado entre un conmutador sin PoE y el PD.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Los dispositivos PSE cumplen con las normas IEEE que especifican la potencia m\u00e1xima de salida por puerto y los m\u00e9todos de negociaci\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/poe-pd-powered-device-guide\/\">PD \u2014 Dispositivo alimentado<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un PD es cualquier dispositivo que recibe energ\u00eda de un PSE a trav\u00e9s del cable Ethernet, p. ej., <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/what-is-a-wireless-access-point-wap\/\">puntos de acceso inal\u00e1mbricos (WAPs)<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/ip-internet-protocol-cameras-overview\/\">c\u00e1maras IP<\/a>, tel\u00e9fonos VoIP, conmutadores peque\u00f1os o dispositivos IoT. Los PD deben presentar una impedancia de firma definida para que el PSE pueda detectarlos y habilitar de forma segura la alimentaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cada PD incluye una <strong>interfaz PoE<\/strong> con circuitos de detecci\u00f3n y conversi\u00f3n CC-CC, lo que le permite operar de forma segura y eficiente con la tensi\u00f3n suministrada (normalmente 44\u201357 V CC).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >C\u00f3mo trabajan conjuntamente el PSE y el PD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Una conexi\u00f3n PoE comienza con un <strong>protocolo de reconocimiento<\/strong> \u2014 un proceso de detecci\u00f3n para confirmar si el dispositivo conectado es compatible con PoE. El PSE aplica una peque\u00f1a tensi\u00f3n para identificar la <em>resistencia de firma<\/em>.<br\/>del PD. Si es v\u00e1lida, el PSE procede con la <strong>clasificaci\u00f3n<\/strong>, determinando la cantidad de energ\u00eda que necesita el PD (p. ej., Clase 0\u20138).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una vez confirmado, el PSE aplica la tensi\u00f3n de funcionamiento completa y comienza la entrega de energ\u00eda, mientras que el convertidor interno del PD estabiliza la energ\u00eda para su circuito.<br\/>Los sistemas PoE+ y PoE++ modernos tambi\u00e9n pueden usar <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/lldp-in-power-over-ethernet-systems\/\"><strong>LLDP (protocolo de descubrimiento de capa de enlace)<\/strong><\/a> negociaci\u00f3n de energ\u00eda din\u00e1mica.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >para negociar la energ\u00eda de forma din\u00e1mica, mejorando la eficiencia energ\u00e9tica y el control de la red.<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 135px;\"\/><col style=\"width: 99px;\"\/><col style=\"width: 105px;\"\/><col style=\"width: 114px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p><strong>Est\u00e1ndar<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p><strong>\u03a4\u03cd\u03c0\u03bf\u03c2<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p><strong>Potencia m\u00e1xima del PSE<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p><strong>Potencia disponible en el dispositivo alimentado (PD)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Aplicaciones t\u00edpicas<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p>IEEE 802.3af<br\/><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/ieee-802-3af-poe-standard-explained\/\">(PoE)<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p>Tipo 1<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p>15,4 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p>12,95 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Tel\u00e9fonos IP, Puntos de acceso inal\u00e1mbricos b\u00e1sicos<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p>IEEE 802.3at<br\/><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/ieee-802-3at-power-over-ethernet-plus-standard\/\">(PoE+)<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p>Tipo 2 <\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p>30 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p>25,5 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>C\u00e1maras PTZ, Puntos de acceso de doble banda<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p>IEEE 802.3bt<br\/><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/what-is-ieee-802-3-bt-poe-standard\/\">(PoE++)<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p>Tipo 3<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p>60 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p>51 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Clientes ligeros, Terminales POS<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p>IEEE 802.3bt<br\/>(PoE++)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p>Tipo 4 <\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p>90\u2013100 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p>71\u201373 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>C\u00e1maras Pan-Tilt-Zoom, Paneles LED, Controladores de acceso<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Nota:<\/strong> La diferencia entre la potencia del PSE y la del PD se debe a las p\u00e9rdidas por resistencia del cable.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Estas normas garantizan la compatibilidad entre fabricantes y protegen los equipos contra fallos el\u00e9ctricos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Consideraciones pr\u00e1cticas al seleccionar PSE y PD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Ajuste a la norma:<\/strong><br\/>Aseg\u00farese de que su PSE soporte la clase de potencia del PD. Usar un conmutador PoE (802.3af) para una c\u00e1mara PoE+ provocar\u00e1 un fallo de alimentaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Planificaci\u00f3n del presupuesto de potencia:<\/strong><br\/>Los conmutadores comparten la potencia total entre todos los puertos; siempre reserve un margen para cargas m\u00e1ximas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Verificaci\u00f3n del cableado:<\/strong><br\/>Las altas potencias <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/what-is-ieee-802-3-bt-poe-standard\/\">(PoE++)<\/a> requieren cables Cat6 o Cat6a para reducir el calentamiento y las p\u00e9rdidas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Gesti\u00f3n t\u00e9rmica y de seguridad:<\/strong><br\/>Las instalaciones de alta potencia deben seguir las recomendaciones de agrupamiento de cables y reducci\u00f3n de capacidad (derating) de la IEEE.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Uso de componentes conformes:<\/strong><br\/>Componentes certificados <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491473.htm\">conectores PoE RJ45<\/a> y magn\u00e9ticos garantizan aislamiento, supresi\u00f3n de interferencias electromagn\u00e9ticas (EMI) y manejo seguro de la corriente.<\/p>","protected":false},"excerpt":{"rendered":"<p>Learn the difference between PSE and PD in PoE networks, how detection &#038; classification work, and which LINK-PP PoE RJ45 products suit your WAP, camera or VoIP deployment.<\/p>","protected":false},"author":1,"featured_media":4719,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[22],"class_list":["post-4720","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-integrated-rj45-connectors"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4720","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=4720"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4720\/revisions"}],"predecessor-version":[{"id":11355,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4720\/revisions\/11355"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/4719"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=4720"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=4720"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=4720"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}