{"id":4643,"date":"2025-10-22T11:12:00","date_gmt":"2025-10-22T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/25g-optical-modules-for-hyperscale-data-centers\/"},"modified":"2026-06-22T06:06:39","modified_gmt":"2026-06-22T06:06:39","slug":"25g-optical-modules-for-hyperscale-data-centers","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/25g-optical-modules-for-hyperscale-data-centers","title":{"rendered":"\u039f\u03c0\u03c4\u03b9\u03ba\u03bf\u03af \u039c\u03b5\u03c4\u03b1\u03b4\u03cc\u03c4\u03b5\u03c2 25G \u03b3\u03b9\u03b1 \u03a5\u03c0\u03b5\u03c1\u03ba\u03bb\u03af\u03bc\u03b1\u03ba\u03b1 \u039a\u03ad\u03bd\u03c4\u03c1\u03b1 \u0394\u03b5\u03b4\u03bf\u03bc\u03ad\u03bd\u03c9\u03bd"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c87262fe663c457ba505d5b9fd3e36eb.webp\" alt=\"25G Optical Transceivers for Hyperscale Data Centers\" class=\"wp-image-4640\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c87262fe663c457ba505d5b9fd3e36eb.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c87262fe663c457ba505d5b9fd3e36eb-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c87262fe663c457ba505d5b9fd3e36eb-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c87262fe663c457ba505d5b9fd3e36eb-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c87262fe663c457ba505d5b9fd3e36eb-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u25b6 Introducci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A medida que los centros de datos contin\u00faan evolucionando hacia mayor densidad y mayor velocidad de transferencia, <strong>Ethernet 25G<\/strong> ha surgido como un bloque fundamental clave en la infraestructura moderna de hipercalentamiento. Dise\u00f1ados para ofrecer 2,5\u00d7 el ancho de banda de Ethernet 10G con cambios m\u00ednimos en los cables y la infraestructura, los m\u00f3dulos \u00f3pticos de 25G logran el equilibrio ideal entre rendimiento, eficiencia energ\u00e9tica y escalabilidad.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este art\u00edculo explora por qu\u00e9 <strong>los m\u00f3dulos \u00f3pticos SFP28 de 25G<\/strong> se han convertido en la opci\u00f3n preferida para los centros de datos de hipercalentamiento, sus est\u00e1ndares t\u00e9cnicos, modelos de implementaci\u00f3n y c\u00f3mo <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\"><strong>los m\u00f3dulos \u00f3pticos LINK-PP de 25G<\/strong><\/a> respaldan estos entornos exigentes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u25b6 \u00bfPor qu\u00e9 es importante Ethernet 25G en entornos de hipercalentamiento?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los centros de datos modernos de hipercalentamiento requieren enlaces de alta velocidad y consistentes entre <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/search\/?keyword=servers\">servidores<\/a>, interruptores de parte superior del bastidor (ToR) y capas de agregaci\u00f3n. <strong>Ethernet 25G<\/strong>, estandarizado por <strong>IEEE 802.3by<\/strong>, ofrece conectividad de 25 Gbps por canal \u00fanico mediante el factor de forma compacto <strong>SFP28<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En comparaci\u00f3n con 10G, 25G ofrece:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Un ancho de banda 2,5\u00d7 mayor por puerto<\/strong><\/p><\/li>\n\n\n\n<li><p><strong>Menor consumo de energ\u00eda por gigabit<\/strong><\/p><\/li>\n\n\n\n<li><p><strong>Menor costo por bit transmitido<\/strong><\/p><\/li>\n\n\n\n<li><p><strong>Escalabilidad sin problemas a 100G (4 canales de 25G)<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Esto convierte a 25G en una soluci\u00f3n ideal para centros de datos que buscan actualizaciones incrementales sin reemplazar por completo su infraestructura existente.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u25b6 Resumen t\u00e9cnico: interior del SFP28 de 25G<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\"><strong>El transceptor \u00f3ptico SFP28 de 25G<\/strong><\/a> opera a 25,78125 Gbps y utiliza un solo canal el\u00e9ctrico. Admite distintos alcances y longitudes de onda seg\u00fan el tipo de fibra y el escenario de aplicaci\u00f3n:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 161px;\"\/><col style=\"width: 153px;\"\/><col style=\"width: 119px;\"\/><col style=\"width: 145px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"161\"><p>Tipo de m\u00f3dulo<br><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"153\"><p>Longitud de onda<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"119\"><p>Tipo de fibra<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"145\"><p>Distancia<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Uso t\u00edpico<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"161\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473141.htm\"><strong>SFP28-SR<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"153\"><p>850nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"119\"><p>MMF<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"145\"><p>70\u2013100 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces dentro del bastidor y entre servidores y switches ToR<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"161\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476046.htm\"><strong>SFP28-LR<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"153\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"119\"><p>SMF<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"145\"><p>Hasta 10 km<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de agregaci\u00f3n<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"161\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476827.htm\"><strong>SFP28-ER<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"153\"><p>1310\/1550 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"119\"><p>SMF<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"145\"><p>Hasta 40 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Metro o campus<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"161\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476090.htm\"><strong>SFP28 BiDi<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"153\"><p>TX\/RX 1270\/1330 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"119\"><p>SMF<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"145\"><p>10km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>D\u00faplex sobre fibra \u00fanica<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"161\"><p><strong>DAC \/ AOC de 25G<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"153\"><p>Cobre \/ Fibra<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"119\"><p>\u2013<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"145\"><p>1\u201330 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Distancias cortas, baja latencia<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Cada tipo de m\u00f3dulo cumple con <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/optical-transceivers-msa-standards-guide\/\"><strong>Acuerdo Multifabricante (MSA)<\/strong><\/a> \u03ba\u03b1\u03b9 <strong>la conformidad IEEE<\/strong>, garantizando una amplia interoperabilidad con los principales fabricantes de switches y NIC.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u25b6 Aplicaciones en centros de datos de hipercalentamiento<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><p><strong>Conectividad servidor-a-ToR<\/strong><br>Los m\u00f3dulos SFP28 de 25G conectan los servidores <a href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/what-is-nic-network-interface-card\/\" target=\"_blank\" rel=\"\">NIC<\/a> a los switches de parte superior del bastidor, ofreciendo conexiones de alta densidad y baja latencia con excelente eficiencia energ\u00e9tica.<\/p><\/li>\n\n\n\n<li><p><strong>Arquitectura leaf-spine<\/strong><br>25G sirve como est\u00e1ndar para los puertos de acceso en la capa leaf, mientras que los enlaces ascendentes spine escalan hasta 100G o 400G mediante m\u00faltiples canales de 25G, permitiendo una transici\u00f3n fluida para el crecimiento de la red.<\/p><\/li>\n\n\n\n<li><p><a href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/link-pp-optical-modules-ai-iot-big-data-performance-reliability\/\" target=\"_blank\" rel=\"\"><strong>Cargas de trabajo en la nube e IA<\/strong><\/a><br>Con la explosi\u00f3n de la inferencia de IA y el an\u00e1lisis de big data, Ethernet 25G proporciona la velocidad y confiabilidad necesarias para sistemas distribuidos <a href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/optical-modules-in-gpu-clusters\/\" target=\"_blank\" rel=\"\">Cl\u00fasteres GPU<\/a> y de procesamiento de datos en tiempo real.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">\u25b6 Ventajas de los m\u00f3dulos \u00f3pticos LINK-PP de 25G<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a9ad0f6a110a447a84a01fd84e99c787.webp\" alt=\"LINK-PP 25G Optical Modules\" class=\"wp-image-4641\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a9ad0f6a110a447a84a01fd84e99c787.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a9ad0f6a110a447a84a01fd84e99c787-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a9ad0f6a110a447a84a01fd84e99c787-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a9ad0f6a110a447a84a01fd84e99c787-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a9ad0f6a110a447a84a01fd84e99c787-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>LINK-PP<\/strong>, fabricante profesional de componentes de conectividad Ethernet, ofrece un portafolio completo de <strong>transceptores \u00f3pticos SFP28 de 25G<\/strong> optimizados para redes de centros de datos y telecomunicaciones.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Beneficios clave de <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">Serie LINK-PP de 25G<\/a>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Compatibilidad total<\/strong> con los est\u00e1ndares IEEE 802.3by y SFP28 MSA<\/p><\/li>\n\n\n\n<li><p><strong>Bajo consumo de energ\u00eda (&lt;1,5 W t\u00edpico)<\/strong> para dise\u00f1os de bastidores energ\u00e9ticamente eficientes<\/p><\/li>\n\n\n\n<li><p><strong>Supervisi\u00f3n digital de diagn\u00f3sticos (<\/strong><a href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/ddm-dom-in-optical-transceivers\/\" target=\"_blank\" rel=\"\"><strong>DDM\/DOM<\/strong><\/a><strong>)<\/strong> para seguimiento en tiempo real del rendimiento del enlace<\/p><\/li>\n\n\n\n<li><p><strong>Blindaje EMI superior<\/strong> y estabilidad t\u00e9rmica para operaci\u00f3n continua las 24 horas del d\u00eda, los 7 d\u00edas de la semana<\/p><\/li>\n\n\n\n<li><p><strong>Alternativas rentables<\/strong> a \u00f3pticas OEM de marca, con la misma confiabilidad e interoperabilidad<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u25b6 Buenas pr\u00e1cticas para migraci\u00f3n e implementaci\u00f3n<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Aproveche la infraestructura de fibra existente:<\/strong> <a href=\"https:\/\/www.l-p.com\/products\/473141.htm\" target=\"_blank\" rel=\"\">los m\u00f3dulos SFP28-SR de 25G<\/a> suelen reutilizar los cables OM3\/OM4 existentes de implementaciones de 10G, reduciendo los costos de actualizaci\u00f3n.<\/p><\/li>\n\n\n\n<li><p><strong>Planifique la agregaci\u00f3n a 100G:<\/strong> Las interfaces de 25G escalan naturalmente a arquitecturas de 100G (4\u00d725G) y 400G (16\u00d725G).<\/p><\/li>\n\n\n\n<li><p><strong>Supervise la salud del enlace:<\/strong> Use las funciones DDM para mantenimiento predictivo y an\u00e1lisis de potencia \u00f3ptica.<\/p><\/li>\n\n\n\n<li><p><strong>Combine con soluciones DAC\/AOC:<\/strong> Para conexiones cortas (\u22645 m), los cables DAC de 25G minimizan la latencia y el costo.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u25b6 Conclusi\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A medida que los centros de datos de hipercalentamiento escalan para satisfacer las demandas de ancho de banda de la IA, el IoT y las cargas de trabajo en la nube, <strong>Ethernet 25G<\/strong> se ha demostrado que es la opci\u00f3n m\u00e1s eficiente y escalable para la conectividad de servidores.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Con su robustez, eficiencia energ\u00e9tica y interoperabilidad, <strong>los m\u00f3dulos \u00f3pticos SFP28 de 25G<\/strong>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>LINK-PP<\/strong><\/a> ofrece soluciones fiables que ayudan a los centros de datos a alcanzar un mayor rendimiento, una gesti\u00f3n simplificada y un menor costo total de propiedad.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para conectividad \u00f3ptica de alto rendimiento que resuelva hoy los desaf\u00edos de red del ma\u00f1ana, explore <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\"><strong>los m\u00f3dulos \u00f3pticos LINK-PP de 25G<\/strong> <\/a>\u2014 dise\u00f1ado para el rendimiento, creado para el crecimiento a escala hipercalentamiento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udd17 <strong>Explore la l\u00ednea completa de productos de 25G de LINK-PP:<\/strong><br>\ud83d\udc49 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>\u0391\u03bd\u03b1\u03ba\u03b1\u03bb\u03cd\u03c8\u03c4\u03b5 \u03c0\u03ce\u03c2 \u03c4\u03b1 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ac \u03bc\u03cc\u03bd\u03c4\u03bf\u03c5\u03bb LINK-PP 25G SFP28 \u03b5\u03bd\u03b9\u03c3\u03c7\u03cd\u03bf\u03c5\u03bd \u03c4\u03b1 \u03c5\u03c0\u03b5\u03c1\u03ba\u03bb\u03af\u03bc\u03b1\u03ba\u03b1 \u03ba\u03ad\u03bd\u03c4\u03c1\u03b1 \u03b4\u03b5\u03b4\u03bf\u03bc\u03ad\u03bd\u03c9\u03bd \u03bc\u03b5 \u03c5\u03c8\u03b7\u03bb\u03cc \u03b5\u03cd\u03c1\u03bf\u03c2 \u03b6\u03ce\u03bd\u03b7\u03c2, \u03c7\u03b1\u03bc\u03b7\u03bb\u03ae \u03ba\u03b1\u03b8\u03c5\u03c3\u03c4\u03ad\u03c1\u03b7\u03c3\u03b7 \u03ba\u03b1\u03b9 \u03b5\u03bd\u03b5\u03c1\u03b3\u03b5\u03b9\u03b1\u03ba\u03ae \u03b1\u03c0\u03cc\u03b4\u03bf\u03c3\u03b7. \u039c\u03ac\u03b8\u03b5\u03c4\u03b5 \u03c4\u03b1 \u03b2\u03b1\u03c3\u03b9\u03ba\u03ac \u03c0\u03bb\u03b5\u03bf\u03bd\u03b5\u03ba\u03c4\u03ae\u03bc\u03b1\u03c4\u03b1 \u03ba\u03b1\u03b9 \u03c4\u03b9\u03c2 \u03c0\u03b5\u03c1\u03b9\u03c0\u03c4\u03ce\u03c3\u03b5\u03b9\u03c2 \u03c7\u03c1\u03ae\u03c3\u03b7\u03c2.<\/p>","protected":false},"author":1,"featured_media":4642,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[16,26],"class_list":["post-4643","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-link-pp-25g-sfp28-optical-modules","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4643","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=4643"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4643\/revisions"}],"predecessor-version":[{"id":10989,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4643\/revisions\/10989"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/4642"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=4643"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=4643"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=4643"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}