{"id":4626,"date":"2025-10-23T11:12:00","date_gmt":"2025-10-23T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/rj45-magjacks-between-plc-and-scada-host\/"},"modified":"2026-06-22T09:00:57","modified_gmt":"2026-06-22T09:00:57","slug":"rj45-magjacks-between-plc-and-scada-host","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/rj45-magjacks-between-plc-and-scada-host","title":{"rendered":"RJ45 Magjack \u2013 \u0394\u03b9\u03b5\u03c0\u03b1\u03c6\u03ae \u03b5\u03c0\u03b9\u03ba\u03bf\u03b9\u03bd\u03c9\u03bd\u03af\u03b1\u03c2 Ethernet \u03bc\u03b5\u03c4\u03b1\u03be\u03cd PLC \u03ba\u03b1\u03b9 \u03ba\u03b5\u03bd\u03c4\u03c1\u03b9\u03ba\u03bf\u03cd \u03c3\u03c4\u03b1\u03b8\u03bc\u03bf\u03cd SCADA"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61.webp\" alt=\"RJ45 Magjacks Between PLC and SCADA Host\" class=\"wp-image-4622\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6155cfaa516e4605ac03cabecce18b61-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">En la automatizaci\u00f3n industrial moderna, el v\u00ednculo entre los controladores l\u00f3gicos programables (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/plc-programmable-logic-controller-for-industrial-automation-guide\/\"><strong>PLC<\/strong><\/a>) y los sistemas de adquisici\u00f3n de datos y control de supervisi\u00f3n (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/what-is-scada-systems\/\"><strong>SCADA<\/strong><\/a>) depende de una conectividad Ethernet fiable. En el coraz\u00f3n de dicha conectividad se encuentra el <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\"><strong>conector RJ45 Magjack<\/strong><\/a>\u2014un conector Ethernet que integra magn\u00e9ticos y apantallamiento para garantizar la integridad de la se\u00f1al, la inmunidad al ruido y la robustez del sistema. Este art\u00edculo analiza el papel clave de los conectores Magjack en la ruta de comunicaci\u00f3n entre PLC y SCADA, desglosa sus caracter\u00edsticas t\u00e9cnicas y explica c\u00f3mo contribuyen a la fiabilidad de Ethernet industrial.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 \u00bfPor qu\u00e9 importa la conexi\u00f3n entre el PLC y el host SCADA?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En una arquitectura de automatizaci\u00f3n t\u00edpica, un PLC (o unidad terminal remota, RTU) recopila datos de dispositivos de campo e intercambia dicha informaci\u00f3n con el host SCADA para su supervisi\u00f3n, control y an\u00e1lisis. Por ejemplo, los sensores transmiten mediciones al PLC; este env\u00eda datos y recibe \u00f3rdenes de control mediante Ethernet al servidor SCADA o estaci\u00f3n maestra. Dentro de esta cadena, la interfaz Ethernet debe ofrecer:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Transferencia de datos de alta velocidad y baja latencia<\/strong> para que los operadores de SCADA dispongan de visibilidad y control en tiempo real.<\/p><\/li>\n\n\n\n<li><p><strong>Integridad f\u00edsica y de se\u00f1al robusta<\/strong> en entornos industriales exigentes (interferencia electromagn\u00e9tica [EMI], potenciales de tierra, vibraci\u00f3n, temperaturas extremas).<\/p><\/li>\n\n\n\n<li><p><strong>Aislamiento galv\u00e1nico y protecci\u00f3n<\/strong> frente a sobretensiones transitorias o <strong>bucles de tierra<\/strong> entre dispositivos distribuidos.<\/p><\/li>\n\n\n\n<li><p><strong>Dise\u00f1o eficiente del espacio en la placa<\/strong> para adaptarse a m\u00f3dulos compactos de PLC y tarjetas de red de control.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dado que dicha interfaz suele utilizar un conector RJ45 montado sobre la placa de circuito impreso (PCB), elegir el <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">conector<\/a> adecuado resulta cr\u00edtico para la fiabilidad general del sistema.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 \u00bfQu\u00e9 es un Magjack RJ45?<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab.jpg\" alt=\"What Is an RJ45 Magjack?\" class=\"wp-image-4623\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab-300x178.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab-1024x608.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab-768x456.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8ac0179909a048778b276ddac09035ab-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">An <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/magnetic-rj45-jack-integrated-connector-modules\/\">conector RJ45 Magjack<\/a> es un conector modular Ethernet (8P8C) <strong>con magn\u00e9ticos integrados<\/strong> (transformadores de aislamiento, filtros de modo com\u00fan, a veces LEDs de estado y carcasa blindada) incorporados directamente en el m\u00f3dulo del conector. <br>Las ventajas clave incluyen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Acondicionamiento y aislamiento de la se\u00f1al:<\/strong> Los magn\u00e9ticos integrados (transformador + filtros) ayudan a suprimir el ruido, reducir reflexiones y diafon\u00eda, y proporcionan aislamiento galv\u00e1nico (t\u00edpicamente 1,5 kVrms o superior) entre el dispositivo y la red. <\/p><\/li>\n\n\n\n<li><p><strong>Rendimiento EMI\/CEM:<\/strong> La carcasa blindada junto con los magn\u00e9ticos internos ofrece una mejor inmunidad en entornos industriales con alto nivel de ruido el\u00e9ctrico (motores, variadores de frecuencia, fuentes de alimentaci\u00f3n conmutadas). <\/p><\/li>\n\n\n\n<li><p><strong>Eficiencia del espacio en la placa y dise\u00f1o simplificado:<\/strong> Al estar ya integrados los componentes magn\u00e9ticos discretos dentro del Magjack, el dise\u00f1o de la PCB se vuelve m\u00e1s sencillo y compacto, lo cual es fundamental para m\u00f3dulos PLC y tarjetas de red compactas. <\/p><\/li>\n\n\n\n<li><p><strong>Versatilidad para Ethernet industrial:<\/strong> Muchos Magjack admiten Ethernet 10\/100 Base-T y Gigabit Ethernet, compatibilidad con PoE\/PoE+ y montaje para uso industrial. <\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Por tanto, al vincular un PLC con un host SCADA mediante Ethernet, el Magjack garantiza que la capa f\u00edsica no se convierta en un eslab\u00f3n d\u00e9bil.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 C\u00f3mo los Magjack sirven en la ruta PLC \u2194 SCADA<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Interfaz f\u00edsica en el lado del PLC<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En el m\u00f3dulo PLC o en el controlador de automatizaci\u00f3n integrado, el <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">Conector RJ45 integrado<\/a> proporciona el puerto Ethernet que se conecta a switches de red o directamente a los concentradores del servidor SCADA. En esta etapa, el Magjack asegura que el PHY Ethernet del PLC vea una interfaz limpia y aislada, inmune a diferencias de potencial de tierra o impulsos de EMI intensos provenientes de la planta.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Conectividad de red e integridad de la transmisi\u00f3n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Entre el PLC y el host SCADA, los cables Ethernet (Cat5e\/Cat6), <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/what-is-a-network-switch\/\">Conmutadores<\/a>, o switches Ethernet industriales transmiten tramas de datos. Los magn\u00e9ticos y el apantallamiento integrados en el Magjack ayudan a mantener la integridad de la se\u00f1al a lo largo de estos cables y a trav\u00e9s de zonas electromagn\u00e9ticamente agresivas. Esto reduce la p\u00e9rdida de paquetes, minimiza los reintentos y mantiene estable la comunicaci\u00f3n determinista\u2014fundamental para los bucles de control SCADA.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Lado del host\/SCADA y fiabilidad del sistema completo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En el lado del host SCADA o estaci\u00f3n maestra, el Magjack RJ45 vuelve a actuar como enlace f\u00edsico. Cualquier degradaci\u00f3n de la interfaz (aislamiento deficiente, susceptibilidad a la EMI) podr\u00eda provocar omisiones de datos, alarmas err\u00f3neas o retrasos en el control. Al usar Magjack, los dise\u00f1adores de sistemas refuerzan la fiabilidad de toda la arquitectura PLC \u2194 SCADA.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Requisitos de la automatizaci\u00f3n industrial<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En entornos de automatizaci\u00f3n industrial (por ejemplo, plantas de fabricaci\u00f3n, subestaciones el\u00e9ctricas, plantas de tratamiento de agua), la interfaz Ethernet debe resistir tensiones mec\u00e1nicas, polvo, vibraci\u00f3n, alta humedad y cambios frecuentes de cable. Los m\u00f3dulos Magjack dise\u00f1ados para montaje con pines pasantes, retenci\u00f3n mec\u00e1nica robusta y diagn\u00f3stico basado en LEDs ayudan a cumplir estos requisitos. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 Criterios clave de selecci\u00f3n de Magjack RJ45 en sistemas PLC\/SCADA<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Al especificar un Magjack para un enlace PLC-a-SCADA, considere los siguientes atributos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Velocidad y est\u00e1ndar Ethernet<\/strong>: Aseg\u00farese de que admita las velocidades de datos requeridas (10\/100 Mb\/s o 5 Gb\/s) y la capacidad auto-MDIX. <\/p><\/li>\n\n\n\n<li><p><strong>Magn\u00e9ticos integrados<\/strong>: Deben estar integrados los transformadores y filtros, calificados para <a href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/lan-transformer-isolation-voltage-explained\/\" target=\"_blank\" rel=\"\">de aislamiento<\/a> (por ejemplo, <strong>1500 Vrms<\/strong>), minimizando los componentes externos. <\/p><\/li>\n\n\n\n<li><p><strong>Clasificaci\u00f3n EMI\/CEM y carcasa blindada<\/strong>: Para entornos industriales, busque certificaciones o ensayos como IEC61000-4-2\/\u22124-3, etc.<\/p><\/li>\n\n\n\n<li><p><strong>Montaje mec\u00e1nico<\/strong>: Las versiones con pines pasantes ofrecen mayor resistencia a la vibraci\u00f3n y mayor resiliencia que las montadas en superficie para placas PLC en entornos exigentes. <\/p><\/li>\n\n\n\n<li><p><strong>Compatibilidad con PoE\/PoE+<\/strong>: Si el PLC o el nodo perif\u00e9rico requiere energ\u00eda mediante Ethernet, aseg\u00farese de que el conector Magjack admita <a href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/ieee-802-3af-vs-ieee-802-3at-vs-ieee-802-3bt\/\" target=\"_blank\" rel=\"\">IEEE 802.3af\/at\/bt<\/a>.<\/p><\/li>\n\n\n\n<li><p><strong>Diagn\u00f3stico (LED)<\/strong>: Conexi\u00f3n\/actividad <a href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/rj45-connector-with-led-functions\/\" target=\"_blank\" rel=\"\">LED<\/a> ofrecen diagn\u00f3sticos r\u00e1pidos en campo, lo cual resulta valioso para el mantenimiento de redes SCADA.<\/p><\/li>\n\n\n\n<li><p><strong>Ecosistema del fabricante y ciclo de vida<\/strong>: Para la automatizaci\u00f3n industrial, elija conectores de fabricantes confiables <a href=\"https:\/\/www.l-p.com\/\" target=\"_blank\" rel=\"\">fabricantes<\/a> con soporte prolongado para el ciclo de vida del producto.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 Consejos para la integraci\u00f3n en interfaces Ethernet PLC\u2013SCADA<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Segmentaci\u00f3n del tr\u00e1fico de red Ethernet<\/strong>: Para los enlaces SCADA, mantenga el tr\u00e1fico de control separado del tr\u00e1fico de oficina; utilice VLAN o interruptores f\u00edsicamente independientes para reducir la latencia y evitar interferencias.<\/p><\/li>\n\n\n\n<li><p><strong>Tendido de cables y puesta a tierra<\/strong>: Evite tender cables Ethernet en paralelo a l\u00edneas de alto voltaje o alta corriente. Use cables blindados y realice la conexi\u00f3n a tierra del chasis para minimizar bucles de tierra.<\/p><\/li>\n\n\n\n<li><p><strong>\u03a7\u03c1\u03ae\u03c3\u03b7 <\/strong><a href=\"https:\/\/www.l-p.com\/products\/491473.htm\" target=\"_blank\" rel=\"\"><strong>Conectores Magjack industriales<\/strong><\/a>: Seleccione conectores Magjack dise\u00f1ados para uso industrial (temperatura, vibraci\u00f3n, retenci\u00f3n en la placa) para evitar fallos en entornos agresivos.<\/p><\/li>\n\n\n\n<li><p><strong>Diagn\u00f3stico y supervisi\u00f3n peri\u00f3dicos<\/strong>: Utilice los LED de conexi\u00f3n\/actividad y la supervisi\u00f3n de red para detectar degradaciones en la capa f\u00edsica (incremento de retransmisiones de paquetes, ca\u00eddas de conexi\u00f3n) antes de que afecten al rendimiento SCADA.<\/p><\/li>\n\n\n\n<li><p><strong>Redundancia y dise\u00f1o seguro ante fallos<\/strong>: En enlaces cr\u00edticos PLC\u2194SCADA, considere rutas de red redundantes o puertos Magjack duales para garantizar la continuidad ante fallos del conector o del cable.<\/p><\/li>\n\n\n\n<li><p><strong>Mantenimiento proactivo<\/strong>: Reemplace conectores envejecidos, inspeccione las terminaciones de los cables y verifique signos de corrosi\u00f3n o aflojamiento mec\u00e1nico; esta atenci\u00f3n a la capa f\u00edsica mejora la fiabilidad general del sistema SCADA.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 C\u00f3mo LINK-PP respalda interfaces Ethernet PLC \u2194 SCADA fiables<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-1024x608.webp\" alt=\"LPJG0926HENL PoE+ RJ45 Connector\" class=\"wp-image-4624\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111-18x12.webp 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8d83e1e985fc4ac19662aa3c55ffb111.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">En LINK-PP, ofrecemos un amplio portafolio de conectores de alto rendimiento <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">los MagJack RJ45 <\/a>dise\u00f1ados espec\u00edficamente para la automatizaci\u00f3n industrial, incluidos modelos con magn\u00e9ticos integrados, soporte PoE\/PoE+, fuerte retenci\u00f3n mec\u00e1nica y clasificaci\u00f3n de temperatura industrial. Por ejemplo, el <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/439792.htm\">LPJG0926HENL<\/a> se destaca especialmente por su idoneidad en aplicaciones de automatizaci\u00f3n industrial y pasarelas IoT. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Al seleccionar el conector Magjack adecuado de LINK-PP, los dise\u00f1adores de sistemas pueden garantizar que su ruta de comunicaci\u00f3n PLC-a-SCADA permanezca robusta, resistente a interferencias y preparada para el futuro, apoyando as\u00ed los ciclos de vida prolongados t\u00edpicos de los sistemas de automatizaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd01 Conclusi\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En resumen, aunque el software y los protocolos de comunicaci\u00f3n PLC \u2194 SCADA suelen recibir mucha atenci\u00f3n, la interfaz f\u00edsica es igualmente cr\u00edtica. El <strong>conector RJ45 Magjack<\/strong> desempe\u00f1a un papel fundamental al proporcionar una interfaz Ethernet que garantiza la integridad de la se\u00f1al, el aislamiento y la resistencia en entornos industriales exigentes. Cuando se selecciona e integra correctamente, los conectores Magjack contribuyen directamente a la fiabilidad, tiempo de actividad y rendimiento de los sistemas SCADA y las redes de automatizaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para dise\u00f1adores e ingenieros que trabajan en automatizaci\u00f3n industrial, especificar el conector Magjack adecuado no es solo una elecci\u00f3n de componente: es una decisi\u00f3n estrat\u00e9gica que impacta el \u00e9xito operativo a largo plazo. Con <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\">los conectores Magjack industriales de LINK-PP<\/a>, puede construir enlaces Ethernet PLC-a-SCADA m\u00e1s inteligentes, m\u00e1s conectados y m\u00e1s fiables. <strong>enlaces Ethernet PLC-a-SCADA<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0395\u03be\u03b5\u03c1\u03b5\u03c5\u03bd\u03ae\u03c3\u03c4\u03b5 \u03c0\u03ce\u03c2 \u03bf\u03b9 \u03c3\u03c5\u03bd\u03b4\u03ad\u03c4\u03b5\u03c2 RJ45 Magjack \u03b4\u03b9\u03b5\u03c5\u03ba\u03bf\u03bb\u03cd\u03bd\u03bf\u03c5\u03bd \u03b1\u03bd\u03b8\u03b5\u03ba\u03c4\u03b9\u03ba\u03ae \u03b5\u03c0\u03b9\u03ba\u03bf\u03b9\u03bd\u03c9\u03bd\u03af\u03b1 Ethernet \u03bc\u03b5\u03c4\u03b1\u03be\u03cd PLC \u03ba\u03b1\u03b9 \u03ba\u03b5\u03bd\u03c4\u03c1\u03b9\u03ba\u03ce\u03bd \u03c3\u03c4\u03b1\u03b8\u03bc\u03ce\u03bd SCADA \u03c3\u03c4\u03b7 \u03b2\u03b9\u03bf\u03bc\u03b7\u03c7\u03b1\u03bd\u03b9\u03ba\u03ae \u03b1\u03c5\u03c4\u03bf\u03bc\u03b1\u03c4\u03bf\u03c0\u03bf\u03af\u03b7\u03c3\u03b7, \u03b4\u03b9\u03b1\u03c3\u03c6\u03b1\u03bb\u03af\u03b6\u03bf\u03bd\u03c4\u03b1\u03c2 \u03c4\u03b7\u03bd \u03b1\u03ba\u03b5\u03c1\u03b1\u03b9\u03cc\u03c4\u03b7\u03c4\u03b1 \u03c4\u03bf\u03c5 \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2 \u03ba\u03b1\u03b9 \u03c4\u03b7\u03bd \u03b1\u03be\u03b9\u03bf\u03c0\u03b9\u03c3\u03c4\u03af\u03b1 \u03c4\u03bf\u03c5 \u03c3\u03c5\u03c3\u03c4\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2.<\/p>","protected":false},"author":1,"featured_media":4625,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[22],"class_list":["post-4626","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-integrated-rj45-connectors"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=4626"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4626\/revisions"}],"predecessor-version":[{"id":11347,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4626\/revisions\/11347"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/4625"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=4626"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=4626"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=4626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}