{"id":4182,"date":"2025-09-27T11:12:00","date_gmt":"2025-09-27T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/extinction-ratio-importance-signal-quality-data-reliability\/"},"modified":"2026-06-22T06:39:25","modified_gmt":"2026-06-22T06:39:25","slug":"extinction-ratio-importance-signal-quality-data-reliability","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/extinction-ratio-importance-signal-quality-data-reliability","title":{"rendered":"\u00bfQu\u00e9 es la Relaci\u00f3n de Extinci\u00f3n (ER) y por Qu\u00e9 es Importante?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1312\" height=\"736\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f07b9ed2b09748238226a42b4a90c230.webp\" alt=\"What is Extinction Ratio and Why Does It Matter\" class=\"wp-image-4180\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f07b9ed2b09748238226a42b4a90c230.webp 1312w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f07b9ed2b09748238226a42b4a90c230-300x168.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f07b9ed2b09748238226a42b4a90c230-1024x574.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f07b9ed2b09748238226a42b4a90c230-768x431.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/f07b9ed2b09748238226a42b4a90c230-18x10.webp 18w\" sizes=\"(max-width: 1312px) 100vw, 1312px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">En el mundo de la fibra \u00f3ptica, la <strong>relaci\u00f3n de extinci\u00f3n<\/strong> es un par\u00e1metro cr\u00edtico, aunque a menudo pasado por alto, que puede determinar el \u00e9xito o el fracaso de la integridad de la se\u00f1al. Este art\u00edculo explica qu\u00e9 es la relaci\u00f3n de extinci\u00f3n, por qu\u00e9 es importante para reducir las tasas de error de bits en las comunicaciones \u00f3pticas y c\u00f3mo afecta el rendimiento del m\u00f3dulo \u00f3ptico. Tambi\u00e9n exploraremos consejos pr\u00e1cticos para su optimizaci\u00f3n e introduciremos <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a>\u2019s de alto rendimiento <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>m\u00f3dulos \u00f3pticos<\/strong><\/a>. Ya sea que usted sea ingeniero o entusiasta tecnol\u00f3gico, obtendr\u00e1 informaci\u00f3n valiosa sobre c\u00f3mo lograr una transmisi\u00f3n de datos fiable.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Conclusiones clave<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Relaci\u00f3n de extinci\u00f3n<\/strong> muestra qu\u00e9 tan bien un sistema distingue las se\u00f1ales fuertes de las d\u00e9biles. Una relaci\u00f3n alta significa que las se\u00f1ales son m\u00e1s f\u00e1ciles de identificar.<\/p><\/li><li><p>Puede calcularse la relaci\u00f3n de extinci\u00f3n con esta f\u00f3rmula: Potencia (Encendido) dividida por Potencia (Apagado). Un n\u00famero mayor indica una se\u00f1al mejor.<\/p><\/li><li><p>Una alta relaci\u00f3n de extinci\u00f3n mejora el funcionamiento del sistema. Ayuda a prevenir errores durante la transmisi\u00f3n de datos y reduce la cantidad de llamadas interrumpidas.<\/p><\/li><li><p>Verificar con frecuencia la relaci\u00f3n de extinci\u00f3n le permite detectar problemas tempranamente. Esto mantiene sus dispositivos funcionando correctamente.<\/p><\/li><li><p>En aplicaciones como las fibras \u00f3pticas y los l\u00e1seres, una relaci\u00f3n de extinci\u00f3n elevada significa que los datos se transmiten r\u00e1pidamente y las im\u00e1genes se ven n\u00edtidas.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Introducci\u00f3n a la relaci\u00f3n de extinci\u00f3n<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En los sistemas de comunicaci\u00f3n \u00f3ptica, los datos se transmiten mediante se\u00f1ales luminosas, donde un \u201c1\u201d l\u00f3gico se representa con un nivel alto de potencia luminosa y un \u201c0\u201d l\u00f3gico con un nivel bajo. La <strong>relaci\u00f3n de extinci\u00f3n<\/strong> cuantifica la distinci\u00f3n entre estos niveles, definida como la relaci\u00f3n entre la potencia durante un bit \u201c1\u201d y la potencia durante un bit \u201c0\u201d. Matem\u00e1ticamente, se expresa como <strong><em>ER = P\u2081 \/ P\u2080<\/em><\/strong><span style=\"font-size: 1px;\">\u200b\u200b<\/span>, habitualmente convertida a decibelios (dB). Una relaci\u00f3n de extinci\u00f3n m\u00e1s alta indica una se\u00f1al m\u00e1s clara, reduciendo el riesgo de errores; piense en ello como la relaci\u00f3n de contraste en una pantalla: un contraste m\u00e1s n\u00edtido significa una mejor legibilidad.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00bfPor qu\u00e9 es esto importante? En redes de alta velocidad, como las de respaldo 5G o los centros de datos, una relaci\u00f3n de extinci\u00f3n deficiente puede provocar un aumento de la <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>tasa de errores de bit (BER)<\/strong><\/a>, degradando el rendimiento. Con la creciente demanda de ancho de banda, optimizar la relaci\u00f3n de extinci\u00f3n se ha vuelto esencial para la <strong>comunicaci\u00f3n por fibra \u00f3ptica<\/strong> eficiencia. Seg\u00fan las normas industriales, una relaci\u00f3n de extinci\u00f3n superior a 10 dB suele ser deseable para muchas aplicaciones, aunque los requisitos var\u00edan seg\u00fan factores como la velocidad de transmisi\u00f3n y la distancia.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1312\" height=\"736\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c7901be8462348018d6a5978d2fc1bac.webp\" alt=\"Extinction ratio (ER)\" class=\"wp-image-4181\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c7901be8462348018d6a5978d2fc1bac.webp 1312w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c7901be8462348018d6a5978d2fc1bac-300x168.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c7901be8462348018d6a5978d2fc1bac-1024x574.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c7901be8462348018d6a5978d2fc1bac-768x431.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c7901be8462348018d6a5978d2fc1bac-18x10.webp 18w\" sizes=\"(max-width: 1312px) 100vw, 1312px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Por qu\u00e9 la relaci\u00f3n de extinci\u00f3n importa en los sistemas \u00f3pticos<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La relaci\u00f3n de extinci\u00f3n desempe\u00f1a un papel fundamental para garantizar la calidad de la se\u00f1al. He aqu\u00ed por qu\u00e9 es un tema candente en <strong>ingenier\u00eda \u00f3ptica<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Impacto en la tasa de error de bits<\/strong>: Una relaci\u00f3n de extinci\u00f3n baja difumina la distinci\u00f3n entre unos y ceros, lo que provoca que el receptor interprete err\u00f3neamente las se\u00f1ales. Esto eleva la <strong>BER<\/strong>, pudiendo causar p\u00e9rdida de datos. Por ejemplo, en <strong>transmisi\u00f3n de largo alcance<\/strong>, incluso una ligera degradaci\u00f3n puede acumularse con la distancia.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\u0391\u03c0\u03bf\u03b4\u03bf\u03c4\u03b9\u03ba\u03cc\u03c4\u03b7\u03c4\u03b1 \u0395\u03bd\u03ad\u03c1\u03b3\u03b5\u03b9\u03b1\u03c2<\/strong>: Una relaci\u00f3n de extinci\u00f3n m\u00e1s alta suele requerir mayor potencia l\u00e1ser, pero mejora la sensibilidad, permitiendo mayores alcances sin necesidad de amplificadores. Esto equilibra el consumo de energ\u00eda y el rendimiento, una consideraci\u00f3n clave en <strong>centros de datos ecol\u00f3gicos<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Compatibilidad con formatos de modulaci\u00f3n<\/strong>: Formatos avanzados como <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong><\/a> (utilizados en Ethernet 400G) exigen relaciones de extinci\u00f3n precisas para mantener la integridad. A medida que evolucionan las redes, las especificaciones de relaci\u00f3n de extinci\u00f3n se vuelven m\u00e1s exigentes.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para ilustrarlo, considere la siguiente tabla, que muestra los requisitos t\u00edpicos de relaci\u00f3n de extinci\u00f3n para distintas aplicaciones:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Aplicaci\u00f3n<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>\u03a4\u03b1\u03c7\u03cd\u03c4\u03b7\u03c4\u03b1<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Requisito t\u00edpico de ER (dB)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Desaf\u00edo principal<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Centro de datos de corto alcance<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 Gbps<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8 \u2013 10 dB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Eficiencia energ\u00e9tica<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Telecomunicaciones de largo alcance<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100 Gbps<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>12 \u2013 15 dB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Atenuaci\u00f3n de la se\u00f1al con la distancia<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Frontera inal\u00e1mbrica 5G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>25 Gbps<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 \u2013 12 dB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mitigaci\u00f3n de interferencias<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Esta tabla resalta c\u00f3mo los requisitos de relaci\u00f3n de extinci\u00f3n escalan con la complejidad. Para los profesionales, monitorear esta m\u00e9trica forma parte de la <strong>optimizaci\u00f3n del rendimiento \u00f3ptico<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Medici\u00f3n y mejora de la relaci\u00f3n de extinci\u00f3n<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La medici\u00f3n precisa es crucial. Herramientas como osciloscopios \u00f3pticos o analizadores de tasa de error de bits (BER) eval\u00faan la relaci\u00f3n de extinci\u00f3n comparando <strong><em>P\u2081 y P\u2080<\/em><\/strong><span style=\"font-size: 1px;\">\u200b\u200b<\/span>. Las mejores pr\u00e1cticas incluyen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Calibraci\u00f3n del equipo<\/strong>: Utilice instrumentos certificados para evitar errores.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Control de temperatura<\/strong>: La salida del l\u00e1ser puede variar con el calor, afectando la relaci\u00f3n. El enfriamiento activo en los m\u00f3dulos ayuda a estabilizarla.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Optimizaci\u00f3n de los circuitos impulsadores<\/strong>: Ajustar las corrientes de polarizaci\u00f3n del l\u00e1ser puede mejorar la relaci\u00f3n de extinci\u00f3n sin comprometer su vida \u00fatil.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd El papel de la relaci\u00f3n de extinci\u00f3n en los m\u00f3dulos \u00f3pticos<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>M\u00f3dulos \u00f3pticos<\/strong><\/a> (o transceptores) son los motores de las redes de fibra, convirtiendo se\u00f1ales el\u00e9ctricas en luz y viceversa. La relaci\u00f3n de extinci\u00f3n es una especificaci\u00f3n fundamental aqu\u00ed, influyendo directamente en la fiabilidad del m\u00f3dulo. En <strong>Transceptores \u00f3pticos<\/strong>, de alta velocidad, una relaci\u00f3n de extinci\u00f3n superior garantiza diagramas de ojo m\u00e1s limpios, que son representaciones visuales de la calidad de la se\u00f1al.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aqu\u00ed es donde entran en juego los <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a> destaca. Como l\u00edder en <strong>m\u00f3dulos \u00f3pticos de alto rendimiento<br><\/strong>, LINK-PP integra tecnolog\u00eda l\u00e1ser avanzada para mantener relaciones de extinci\u00f3n \u00f3ptimas incluso bajo condiciones exigentes. Por ejemplo, el <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476095.htm\"><strong>LS-SM3125-40C<\/strong><\/a> est\u00e1 dise\u00f1ado para aplicaciones de largo alcance, con una relaci\u00f3n de extinci\u00f3n de hasta 12 dB. Esto lo hace ideal para <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/data-center-interconnect-definition-benefits-and-role-of-optical-modules\/\"><strong>interconexiones entre centros de datos (DCI)<\/strong><\/a> donde una baja tasa de error de bits es imprescindible. Al elegir m\u00f3dulos como este, aborda <strong>los requisitos de relaci\u00f3n de extinci\u00f3n en transceptores<\/strong> de forma proactiva, reduciendo tiempos de inactividad.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Adem\u00e1s, el enfoque de LINK-PP en <strong>compatibilidad de m\u00f3dulos \u00f3pticos<\/strong> significa que sus productos cumplen con las normas industriales, asegurando una integraci\u00f3n perfecta. Al seleccionar un m\u00f3dulo, verifique siempre las especificaciones de su relaci\u00f3n de extinci\u00f3n: es un detalle peque\u00f1o con grandes implicaciones para la salud de la red.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Conclusi\u00f3n y pasos siguientes<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Relaci\u00f3n de extinci\u00f3n (ER)<\/strong> no es simplemente una jerga t\u00e9cnica; es una puerta de entrada a la comunicaci\u00f3n \u00f3ptica robusta. Desde la minimizaci\u00f3n de errores hasta la habilitaci\u00f3n de redes listas para el futuro, su importancia no puede exagerarse. Al perfeccionar sus sistemas, recuerde que componentes como <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/optics-transceivers\"><strong>M\u00f3dulos \u00f3pticos LINK-PP<\/strong><\/a> pueden ser decisivos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Preguntas frecuentes<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 significa una relaci\u00f3n de extinci\u00f3n baja para su dispositivo?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Una relaci\u00f3n de extinci\u00f3n baja dificulta que su dispositivo distinga entre \u201cencendido\u201d y \u201capagado\u201d. Es posible que observe m\u00e1s errores o se\u00f1ales d\u00e9biles. Si detecta estos problemas, revise su sistema.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 herramientas puede usar para medir la relaci\u00f3n de extinci\u00f3n?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Puede usar un fotodetector, un osciloscopio o un polarizador. Estas herramientas le ayudan a observar la diferencia entre \u201cencendido\u201d y \u201capagado\u201d.\u201d<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Consejo: siempre use herramientas correctamente configuradas para obtener los mejores resultados.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 provoca la disminuci\u00f3n de la relaci\u00f3n de extinci\u00f3n?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El polvo, las lentes sucias o las piezas da\u00f1adas pueden reducir la relaci\u00f3n de extinci\u00f3n. Limpie sus dispositivos y busque da\u00f1os.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Realizar revisiones peri\u00f3dicas ayuda a mantener alta la relaci\u00f3n de extinci\u00f3n.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1l es un valor adecuado de relaci\u00f3n de extinci\u00f3n?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un valor adecuado de relaci\u00f3n de extinci\u00f3n depende de su sistema. La mayor\u00eda de los sistemas \u00f3pticos funcionan mejor con valores superiores a 10 dB.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Nota: los valores m\u00e1s altos indican se\u00f1ales m\u00e1s n\u00edtidas y menos errores.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 ocurre si ignora la relaci\u00f3n de extinci\u00f3n?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si no verifica la relaci\u00f3n de extinci\u00f3n, su dispositivo podr\u00eda enviar se\u00f1ales ambiguas. Esto puede ralentizar los datos, provocar ca\u00eddas de llamadas o generar errores. Verifique siempre la relaci\u00f3n de extinci\u00f3n para garantizar el buen funcionamiento de su tecnolog\u00eda.<\/p>","protected":false},"excerpt":{"rendered":"<p>La relaci\u00f3n de extinci\u00f3n mide la claridad de la se\u00f1al en los sistemas \u00f3pticos, afectando la fiabilidad de los datos y las tasas de error. Una alta relaci\u00f3n de extinci\u00f3n garantiza una transmisi\u00f3n precisa.<\/p>","protected":false},"author":1,"featured_media":4180,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[24,26],"class_list":["post-4182","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4182","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=4182"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4182\/revisions"}],"predecessor-version":[{"id":11055,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/4182\/revisions\/11055"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/4180"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=4182"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=4182"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=4182"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}