{"id":3793,"date":"2025-11-18T00:00:00","date_gmt":"2025-11-18T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/xlaui-10-lane-attachment-unit-interface-ethernet-explained\/"},"modified":"2026-06-22T05:00:37","modified_gmt":"2026-06-22T05:00:37","slug":"xlaui-10-lane-attachment-unit-interface-ethernet-explained","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/xlaui-10-lane-attachment-unit-interface-ethernet-explained","title":{"rendered":"\u00bfQu\u00e9 es XLAUI? Explicaci\u00f3n de la interfaz de unidad de conexi\u00f3n de 10 v\u00edas"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2.webp\" alt=\"What Is XLAUI? 10-Lane Attachment Unit Interface Explained\" class=\"wp-image-3790\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Introducci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Las redes de alta velocidad requieren interfaces el\u00e9ctricas robustas y normalizadas para garantizar enlaces confiables de 40 Gb\/s entre los ASICs host y los m\u00f3dulos \u00f3pticos enchufables. Una interfaz cr\u00edtica en este \u00e1mbito es la <strong>Interfaz de Unidad de Acoplamiento de 10 canales (XLAUI)<\/strong>, definida en el est\u00e1ndar IEEE 802.3ba. Ingenieros, arquitectos de sistemas e integradores de m\u00f3dulos que implementan m\u00f3dulos QSFP+ de 40 G se benefician de una comprensi\u00f3n clara de XLAUI para asegurar interoperabilidad, integridad de se\u00f1al y rendimiento predecible.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este art\u00edculo explica qu\u00e9 es XLAUI, c\u00f3mo funciona, por qu\u00e9 es relevante en los m\u00f3dulos QSFP+ de 40 G y ofrece perspectivas pr\u00e1cticas utilizando <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\"><strong>m\u00f3dulos LINK-PP QSFP+ de 40 G<\/strong><\/a> como ejemplos del mundo real.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 \u00bfQu\u00e9 es XLAUI?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>XLAUI<\/strong> DDM <strong>Interfaz Extendida de Unidad de Acoplamiento de 10 canales<\/strong>. Es una interfaz el\u00e9ctrica definida en <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/what-is-ieee-802-3ba-standard\/\">IEEE 802.3ba<\/a> \u03b3\u03b9\u03b1 <strong>Ethernet de 40 Gigabit (40GbE)<\/strong>. XLAUI se utiliza para conexiones de <strong>chip a m\u00f3dulo<\/strong> \u03ae <strong>chip a chip<\/strong> , especialmente en m\u00f3dulos enchufables como QSFP+.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edsticas clave:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Estructura de canales:<\/strong> 10 canales paralelos, cada uno operando a ~10,3125 Gb\/s, lo que da un ancho de banda agregado de ~40 Gb\/s de datos de usuario tras la codificaci\u00f3n.<\/p><\/li><li><p><strong>4\u201316 cores<\/strong> Enlaces de host a m\u00f3dulo para backplanes \u00f3pticos o de cobre.<\/p><\/li><li><p><strong>Normas el\u00e9ctricas:<\/strong> Definidas en el Anexo 83A del IEEE 802.3ba, incluyendo par\u00e1metros del transmisor\/receptor, presupuestos de p\u00e9rdida de canal, p\u00e9rdida de retorno y presupuestos de jitter.<\/p><\/li><li><p><strong>Relaci\u00f3n con otras AUI:<\/strong> Forma parte de la familia \u201cInterfaz de Unidad de Acoplamiento\u201d \u2014como XAUI (10GbE) o CAUI (100GbE)\u2014, pero optimizada para 40GbE.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">XLAUI permite velocidades manejables por canal mientras logra un alto ancho de banda agregado, lo que la hace pr\u00e1ctica para dise\u00f1os densos de switches y servidores.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 \u00bfC\u00f3mo funciona XLAUI?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Estructura de canales y velocidad de datos<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Cada uno de los 10 canales transporta ~10,3125 Gb\/s.<\/p><\/li><li><p>Tras la codificaci\u00f3n 64b\/66b, la velocidad agregada de datos de usuario alcanza ~40 Gb\/s.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Funcionamiento del SERDES<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Cada canal utiliza un <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\"><strong>Serializador\/Deserializador (SERDES)<\/strong><\/a> para convertir datos en paralelo a flujos seriales y viceversa.<\/p><\/li><li><p>Los m\u00f3dulos o retimadores pueden usar una <strong>caja reductora (gearbox)<\/strong> para mapear 10 canales el\u00e9ctricos en menos canales \u00f3pticos (p. ej., mapeo 10\u21924).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Requisitos del canal<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>El IEEE 802.3ba especifica la p\u00e9rdida de canal, la p\u00e9rdida de retorno, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/jitter-in-optics-causes-effects-measurement-reduction\/\">jiter<\/a>, y l\u00edmites de desviaci\u00f3n (skew).<\/p><\/li><li><p>Ejemplo: p\u00e9rdida de ~10 dB permitida en la frecuencia de Nyquist (~5,15625 GHz) para trazas t\u00edpicas de PCB FR4 de 250 mm.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Chip-a-M\u00f3dulo frente a Chip-a-Chip<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>XLAUI es principalmente una <strong>chip a m\u00f3dulo<\/strong> interfaz (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/what-is-application-specific-integrated-circuit-asic\/\">ASIC<\/a> \u2192 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\">\u03a0\u03b1\u03c1\u03ac\u03b3\u03c9\u03b3\u03bf \u03a0\u03b1\u03c1\u03ac\u03b3\u03c9\u03b3\u03bf<\/a>).<\/p><\/li><li><p>Tambi\u00e9n puede soportar interconexiones de backplane o PCB con una gesti\u00f3n adecuada de la integridad de se\u00f1al.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Importancia de XLAUI en los m\u00f3dulos QSFP+ de 40G<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb.webp\" alt=\"XLAUI in 40G QSFP+ Modules\" class=\"wp-image-3342\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Mayor densidad de puertos<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Varios carriles de ~10 Gb\/s son m\u00e1s f\u00e1ciles de enrutar que un \u00fanico carril de velocidad ultraalta.<\/p><\/li><li><p>Permite factores de forma compactos QSFP+ y tarjetas de l\u00ednea de alta densidad.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Compatibilidad estandarizada<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La estandarizaci\u00f3n permite que los fabricantes de m\u00f3dulos y ASIC (por ejemplo, LINK-PP) dise\u00f1en seg\u00fan una interfaz com\u00fan.<\/p><\/li><li><p>Se mejora la interoperabilidad en sistemas multi-vendor.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Integridad de se\u00f1al manejable<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Las velocidades moderas de carril simplifican el dise\u00f1o de PCB, la implementaci\u00f3n de conectores hot-plug y reducen los requisitos de retimadores.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Previsi\u00f3n futura<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>XLAUI sigue siendo relevante para m\u00f3dulos legados de 40G y redes de tasas mixtas, incluso con las tecnolog\u00edas emergentes de carril de 25G\/50G.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >M\u00f3dulos LINK-PP QSFP+ de 40G y XLAUI<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9.webp\" alt=\"40G QSFP+ Modules\" class=\"wp-image-3791\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ejemplo:<\/strong> LINK\u2011PP <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\">LQ\u2011CW40\u2011LR4C<\/a> M\u00f3dulo QSFP+ de 40G<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Convierte 4 carriles el\u00e9ctricos de 10 Gb\/s en 4 se\u00f1ales \u00f3pticas CWDM.<\/p><\/li><li><p>Compatible con los est\u00e1ndares el\u00e9ctricos IEEE 802.3ba, implementando efectivamente una operaci\u00f3n de 10 carriles tipo XLAUI en el lado del host.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Implicaciones de dise\u00f1o:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>El ASIC o switch del host debe soportar una <strong>interfaz XLAUI de 10 carriles<\/strong>.<\/p><\/li><li><p>El dise\u00f1o de PCB debe garantizar la integridad de se\u00f1al, la alineaci\u00f3n de carriles y el control de skew.<\/p><\/li><li><p>Verifique la compatibilidad del proveedor respecto al cumplimiento de la interfaz el\u00e9ctrica.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">M\u00f3dulos LINK-PP<\/a> cumplir con los est\u00e1ndares IEEE, lo que permite un rendimiento predecible y una integraci\u00f3n simplificada en sistemas de 40G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Consideraciones de dise\u00f1o y mejores pr\u00e1cticas<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Control de skew entre carriles:<\/strong> Asegure que el skew entre carriles se encuentre dentro de la especificaci\u00f3n para una correcta alineaci\u00f3n de SERDES\/gearbox.<\/p><\/li><li><p><strong>Presupuesto de jitter:<\/strong> Siga las m\u00e1scaras de jitter del transmisor\/receptor IEEE (Anexo 83A).<\/p><\/li><li><p><strong>Presupuesto de p\u00e9rdida de canal:<\/strong> P\u00e9rdida t\u00edpica de ~10 dB a la frecuencia de Nyquist para trazas FR4 de ~250 mm.<\/p><\/li><li><p><strong>Calibraci\u00f3n de SERDES:<\/strong> Implemente pre\u00e9nfasis, CTLE y DFE seg\u00fan sea necesario.<\/p><\/li><li><p><strong>Compatibilidad del m\u00f3dulo:<\/strong> Verifique la alineaci\u00f3n entre la interfaz del host y el factor de forma QSFP+.<\/p><\/li><li><p><strong>Previsi\u00f3n futura:<\/strong> Planifique sistemas de 100 G (CAUI-10) o 400 G con flexibilidad de divisi\u00f3n de canales (lane breakout).<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Resumen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>XLAUI <\/strong>(Interfaz de unidad de conexi\u00f3n de 10 canales) es una <strong>norma cr\u00edtica de interfaz el\u00e9ctrica<\/strong> para sistemas de 40GbE. Al dividir los 40 G en diez canales de ~10,3 Gb\/s, permite implementaciones modulares, de alta densidad e interoperables con transceptores QSFP+. Los ingenieros que integran <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\"><strong>transceptores LINK-PP 40G QSFP+<\/strong><\/a> deben comprender XLAUI para garantizar un dise\u00f1o adecuado de PCB, una configuraci\u00f3n correcta de SERDES y un rendimiento fiable en centros de datos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Preguntas frecuentes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1l es el prop\u00f3sito principal de XLAUI?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">XLAUI proporciona una interfaz el\u00e9ctrica estandarizada de 10 canales entre un ASIC (o PHY) host y un m\u00f3dulo QSFP+ de 40 G. Permite una transferencia fiable de datos a 40 Gb\/s manteniendo velocidades por canal manejables (~10,3125 Gb\/s) para la integridad de la se\u00f1al y el enrutamiento de PCB.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfEn qu\u00e9 se diferencia XLAUI de XAUI o CAUI?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>XAUI:<\/strong> 4 canales para 10GbE (~3,125 Gb\/s por canal tras la codificaci\u00f3n).<\/p><\/li><li><p><strong>XLAUI:<\/strong> 10 canales para 40GbE (~10,3125 Gb\/s por canal).<\/p><\/li><li><p><strong>CAUI:<\/strong> 10 o 20 canales para 100GbE (~10\u201325 Gb\/s por canal).<br\/>XLAUI equilibra un ancho de banda agregado mayor con velocidades moderadas por canal para simplificar el dise\u00f1o del sistema.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfSe puede utilizar XLAUI para conexiones de backplane?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed. Aunque est\u00e1 dise\u00f1ado principalmente para enlaces chip-a-m\u00f3dulo (ASIC \u2192 QSFP+), XLAUI puede soportar interconexiones de backplane o PCB si se cumplen los requisitos de p\u00e9rdida del canal, skew e integridad de la se\u00f1al.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfCu\u00e1l es la funci\u00f3n de SERDES y la caja reductora (gearbox) en XLAUI?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\"><strong>SERDES<\/strong><\/a><strong>:<\/strong> Convierte datos paralelos en flujos seriales (y viceversa) en cada una de las 10 v\u00edas (lanes).<\/p><\/li><li><p><strong>Caja reductora (opcional):<\/strong> Asigna m\u00faltiples v\u00edas el\u00e9ctricas a menos v\u00edas \u00f3pticas dentro del m\u00f3dulo (por ejemplo, 10 v\u00edas el\u00e9ctricas \u2192 4 v\u00edas \u00f3pticas), manteniendo el alineamiento.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfSon todos los m\u00f3dulos QSFP+ de 40 G compatibles con XLAUI?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No todos. Algunos m\u00f3dulos utilizan interfaces el\u00e9ctricas alternativas de 4 v\u00edas, como XLPPI o XLAUI-4. Siempre consulte la hoja de datos del m\u00f3dulo para verificar el n\u00famero de v\u00edas, el tipo de interfaz el\u00e9ctrica y la compatibilidad con el host.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfC\u00f3mo garantizo un correcto alineamiento de v\u00edas e integridad de la se\u00f1al?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Controle el skew entre v\u00edas dentro de las especificaciones de IEEE.<\/p><\/li><li><p>Cumpla con los presupuestos de p\u00e9rdida del canal y de jitter.<\/p><\/li><li><p>Utilice funciones de SERDES, como pre\u00e9nfasis, CTLE y DFE, seg\u00fan se recomiende.<\/p><\/li><li><p>Valide el trazado de PCB, el rendimiento del conector y del retimizador.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfPor qu\u00e9 sigue siendo relevante XLAUI en redes modernas?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A pesar de las tecnolog\u00edas m\u00e1s recientes de v\u00edas de 25 G o 50 G, XLAUI sigue siendo ampliamente utilizado en despliegues heredados de 40 G, dise\u00f1os de QSFP+ de alta densidad y tejidos de centros de datos de tasas mixtas. Proporciona interoperabilidad y una base conocida de rendimiento el\u00e9ctrico.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfC\u00f3mo implementa LINK-PP XLAUI en sus m\u00f3dulos QSFP+ de 40 G?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">Los m\u00f3dulos QSFP+ de 40 G de LINK-PP<\/a> (por ejemplo, LQ-CW40-LR4C) siguen las normas IEEE 802.3ba e implementan v\u00edas el\u00e9ctricas equivalentes a XLAUI para conexiones del lado del host. Esto garantiza un rendimiento predecible y una integraci\u00f3n m\u00e1s sencilla en switches o tarjetas de l\u00ednea que admitan XLAUI de 10 v\u00edas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfQu\u00e9 consideraciones de dise\u00f1o deben tener en cuenta los ingenieros al desplegar XLAUI?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Verifique que el ASIC del host admita XLAUI de 10 v\u00edas.<\/p><\/li><li><p>Aseg\u00farese de que la p\u00e9rdida por inserci\u00f3n del canal, la p\u00e9rdida por retorno y la diafon\u00eda cumplan con las normas.<\/p><\/li><li><p>Alinee correctamente las v\u00edas de SERDES para evitar errores.<\/p><\/li><li><p>Considere las restricciones t\u00e9rmicas y de potencia en despliegues densos.<\/p><\/li><li><p>Planifique las rutas de divisi\u00f3n (breakout) de v\u00edas para futuras actualizaciones (por ejemplo, 100 G o 400 G).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u00bfSe pueden actualizar las interfaces XLAUI a velocidades superiores en el futuro?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed, pero requiere una planificaci\u00f3n cuidadosa. Actualizaciones futuras a CAUI u otras arquitecturas con mayor n\u00famero de v\u00edas podr\u00edan afectar el trazado de PCB, los requisitos del retimizador y la asignaci\u00f3n de SERDES. Una visi\u00f3n anticipada en el dise\u00f1o garantiza la compatibilidad hacia atr\u00e1s con <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">m\u00f3dulos QSFP+ de 40 G.<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>XLAUI (interfaz de unidad de conexi\u00f3n de 10 v\u00edas) permite conexiones de alta velocidad y fiables entre chips anfitriones y m\u00f3dulos QSFP+ en sistemas Ethernet de 40\/100 G.<\/p>","protected":false},"author":1,"featured_media":3792,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[18,26],"class_list":["post-3793","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-40g-qsfp-transceivers","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/3793","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=3793"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/3793\/revisions"}],"predecessor-version":[{"id":10873,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/3793\/revisions\/10873"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/3792"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=3793"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=3793"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=3793"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}