{"id":3628,"date":"2025-11-26T00:00:00","date_gmt":"2025-11-26T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/what-are-tx-fault-and-rx-los-in-optical-transceivers\/"},"modified":"2026-06-22T04:41:35","modified_gmt":"2026-06-22T04:41:35","slug":"what-are-tx-fault-and-rx-los-in-optical-transceivers","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/what-are-tx-fault-and-rx-los-in-optical-transceivers","title":{"rendered":"\u00bfQu\u00e9 son el fallo de transmisi\u00f3n (TX Fault) y la p\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS) en los transceptores \u00f3pticos?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94.webp\" alt=\"Troubleshoot TX Fault and RX LOS\" class=\"wp-image-3624\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>\u039f\u03b9 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u03bc\u03bf\u03bd\u03ac\u03b4\u03b5\u03c2 \u03bc\u03b5\u03c4\u03b1\u03b2\u03af\u03b2\u03b1\u03c3\u03b7\u03c2<\/strong><\/a> son componentes esenciales en las redes modernas de fibra \u00f3ptica, que permiten la transmisi\u00f3n de datos a alta velocidad en centros de datos, sistemas de telecomunicaciones, automatizaci\u00f3n industrial y entornos de conmutaci\u00f3n empresarial.<br\/>Para mantener la estabilidad, la mayor\u00eda de los m\u00f3dulos SFP, SFP+, SFP28 y QSFP proporcionan dos indicadores clave de diagn\u00f3stico: <strong>Fallo de transmisi\u00f3n (TX Fault)<\/strong> \u03ba\u03b1\u03b9 <strong>P\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS)<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Estas se\u00f1ales ayudan a los ingenieros a identificar r\u00e1pidamente problemas \u00f3pticos, prevenir fallos de enlace y garantizar un tiempo de actividad confiable de la red. Este art\u00edculo explica su significado, su funcionamiento y c\u00f3mo solucionarlos de forma eficaz.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Fallo de transmisi\u00f3n (TX Fault): \u00bfqu\u00e9 significa y por qu\u00e9 aparece?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Fallo de transmisi\u00f3n (TX Fault)<\/strong> es una se\u00f1al de hardware utilizada por los transceptores \u00f3pticos para indicar un problema con el <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/laser-types-in-optical-transceiver-modules\/\"><strong>l\u00e1ser del transmisor (TX)<\/strong><\/a>.<br\/>Cuando se activa el fallo de transmisi\u00f3n (normalmente en estado \u201cALTO\u201d), significa que el transmisor no puede operar dentro de sus especificaciones normales.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Causas comunes del fallo de transmisi\u00f3n<\/h3>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Corriente de polarizaci\u00f3n del l\u00e1ser fuera de rango<\/strong><br\/>El m\u00f3dulo detecta condiciones anormales de conducci\u00f3n del l\u00e1ser y desactiva la transmisi\u00f3n como medida de protecci\u00f3n.<\/p><\/li><li><p><strong>Potencia \u00f3ptica de transmisi\u00f3n demasiado baja o demasiado alta<\/strong><br\/>La supervisi\u00f3n interna (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/ddm-dom-in-optical-transceivers\/\">DOM\/DDM<\/a>) activa un fallo si la potencia de salida se desv\u00eda m\u00e1s all\u00e1 de los l\u00edmites establecidos.<\/p><\/li><li><p><strong>Condici\u00f3n de sobrecalentamiento<\/strong><br\/>Las temperaturas excesivas pueden afectar el rendimiento del l\u00e1ser, provocando su apagado autom\u00e1tico.<\/p><\/li><li><p><strong>TOSA (subconjunto \u00f3ptico transmisor) defectuoso o da\u00f1ado<\/strong><br\/>Da\u00f1os f\u00edsicos o componentes envejecidos pueden provocar una salida l\u00e1ser inestable.<\/p><\/li><li><p><strong>Equipo host incorrecto o no compatible<\/strong><br\/>Algunos switches activan el fallo de transmisi\u00f3n cuando la codificaci\u00f3n o compatibilidad del m\u00f3dulo no coinciden.<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 \u00bfQu\u00e9 ocurre durante un evento de fallo de transmisi\u00f3n?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>El m\u00f3dulo <strong>desactiva el l\u00e1ser<\/strong> por seguridad.<\/p><\/li><li><p>La potencia de salida de transmisi\u00f3n cae a cero.<\/p><\/li><li><p>El sistema host recibe la indicaci\u00f3n de fallo y registra una alarma.<\/p><\/li><li><p>El m\u00f3dulo intenta recuperarse o permanece apagado, seg\u00fan su dise\u00f1o.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 P\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS): \u00bfqu\u00e9 significa y por qu\u00e9 aparece?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>P\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS)<\/strong> indica que el <strong>receptor (RX)<\/strong> receptor del m\u00f3dulo no est\u00e1 detectando suficiente potencia \u00f3ptica para establecer un enlace v\u00e1lido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En t\u00e9rminos sencillos:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>RX LOS = Ausencia de luz o luz insuficiente entrando en el receptor.<\/strong><\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Causas comunes de RX LOS<\/h3>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Fibra desconectada o conectada incorrectamente<\/strong><br\/>Una de las razones m\u00e1s comunes de las alarmas de p\u00e9rdida de se\u00f1al (LOS).<\/p><\/li><li><p><strong>Potencia \u00f3ptica de entrada insuficiente<\/strong><br\/>Si el nivel de potencia recibida est\u00e1 por debajo del umbral de sensibilidad, el m\u00f3dulo declara p\u00e9rdida de se\u00f1al (LOS).<\/p><\/li><li><p><strong>Conectores de fibra sucios, rayados o contaminados<\/strong><br\/>Incluso una ligera contaminaci\u00f3n puede reducir significativamente la potencia \u00f3ptica.<\/p><\/li><li><p><strong>Emparejamiento incorrecto de longitudes de onda (por ejemplo, 1310 nm conectado a 1550 nm)<\/strong><br\/>Las \u00f3pticas incompatibles no podr\u00e1n comunicarse.<\/p><\/li><li><p><strong>Cables de fibra defectuosos o p\u00e9rdida excesiva en el enlace<\/strong><br\/>Curvatura, roturas o atenuaci\u00f3n por distancia excesiva activan la alarma de p\u00e9rdida de se\u00f1al (LOS).<\/p><\/li><li><p><strong>Fallo del transmisor ascendente<\/strong><br\/>El extremo opuesto podr\u00eda no estar transmitiendo luz en absoluto.<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 \u00bfQu\u00e9 ocurre cuando RX LOS est\u00e1 activa?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La salida del receptor se vuelve inv\u00e1lida.<\/p><\/li><li><p>El dispositivo anfitri\u00f3n puede desactivar el puerto o marcar el enlace como inactivo.<\/p><\/li><li><p>Protocolos de capas superiores (por ejemplo, Ethernet o <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/what-is-cpri-common-public-radio-interface\/\">CPRI<\/a>) no logran establecer una conexi\u00f3n.<\/p><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa.webp\" alt=\"TX Fault and RX LOS in Optical Transceivers\" class=\"wp-image-3625\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 TX Fault frente a RX LOS \u2014 Diferencias clave<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 225px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p>Caracter\u00edstica<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Fallo de transmisi\u00f3n (TX Fault)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>P\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>Funci\u00f3n<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Indica problemas del transmisor (l\u00e1ser)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Indica potencia \u00f3ptica recibida insuficiente<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>Activado por<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mal funcionamiento del l\u00e1ser, sobrecalentamiento, desviaci\u00f3n de potencia<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Desconexi\u00f3n de la fibra, potencia baja, conectores sucios<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>Direcci\u00f3n<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Se\u00f1al saliente<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Se\u00f1al entrante<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>Efecto sobre el enlace<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>El l\u00e1ser de transmisi\u00f3n se apaga<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>El receptor no puede detectar luz<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>Tipo de problema<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interno del m\u00f3dulo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interno o externo al enlace<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Comprender ambas se\u00f1ales ayuda a identificar si el problema se debe al <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>\u038a\u03bd\u03b1<\/strong> <strong>transceptor<\/strong><\/a>, LQ-SW100-SR4C <strong>enlace de fibra<\/strong>, o al <strong>dispositivo remoto<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 C\u00f3mo solucionar TX Fault<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Siga estos pasos:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Verifique la temperatura del m\u00f3dulo<\/strong><br\/>Aseg\u00farese de que est\u00e9 dentro del<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/optical-transceivers-operating-temperature-range\/\"> rango operativo<\/a> (por ejemplo, \u201340 \u00b0C a +85 \u00b0C para versi\u00f3n industrial).<\/p><\/li><li><p><strong>Revise los valores DOM\/DDM<\/strong><br\/>Busque corriente de polarizaci\u00f3n del l\u00e1ser o potencia de salida TX anormales.<\/p><\/li><li><p><strong>Limpiar los conectores de fibra<\/strong><br\/>La contaminaci\u00f3n puede causar fluctuaciones de potencia que afectan al transmisor.<\/p><\/li><li><p><strong>Verifique la compatibilidad con el switch<\/strong><br\/>Algunos switches bloquean m\u00f3dulos de terceros o requieren configuraciones como \u201callow-unsupported\u201d.<\/p><\/li><li><p><strong>Intercambie el transceptor<\/strong><br\/>Un TX Fault persistente suele indicar un l\u00e1ser en fallo o <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/glossary\/tosa-in-optical-modules-importance\/\">TOSA<\/a>.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 C\u00f3mo solucionar RX LOS<\/h2>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Verifique si la fibra est\u00e1 correctamente conectada<\/strong><br\/>Los conectores LC deben encajar completamente en el transceptor.<\/p><\/li><li><p><strong>Limpie ambos extremos de la fibra<\/strong><br\/>Use herramientas adecuadas para limpieza de fibra \u2014 nunca limpie con ropa ni papel.<\/p><\/li><li><p><strong>Verifique la compatibilidad de longitudes de onda<\/strong><br\/>Ambos lados deben usar \u00f3pticas compatibles (p. ej., 1310 nm \u2194 1310 nm).<\/p><\/li><li><p><strong>Medir la p\u00e9rdida del enlace<\/strong><br\/>Una atenuaci\u00f3n excesiva puede requerir reemplazar la fibra o ajustar el empalme.<\/p><\/li><li><p><strong>Verificar el transmisor remoto<\/strong><br\/>El transmisor del extremo lejano puede estar defectuoso o apagado.<\/p><\/li><li><p><strong>Intercambiar transceptores y cables<\/strong><br\/>Ayuda a aislar si el problema est\u00e1 en el m\u00f3dulo o en el enlace f\u00edsico.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 C\u00f3mo los transceptores LINK-PP ayudan a prevenir los fallos de TX y los estados de p\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS)<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba.webp\" alt=\"LINK-PP SFP Modules\" class=\"wp-image-3626\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP de grado industrial <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">M\u00f3dulos SFP<\/a> est\u00e1n dise\u00f1ados para un rendimiento \u00f3ptico estable en entornos exigentes.<br\/>Caracter\u00edsticas clave del dise\u00f1o incluyen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Control preciso del l\u00e1ser<\/strong> para minimizar las ocurrencias de fallo de TX<\/p><\/li><li><p><strong>Receptores de alta sensibilidad<\/strong> para una mayor robustez frente a la p\u00e9rdida de se\u00f1al (LOS)<\/p><\/li><li><p><strong>Opciones industriales y de temperatura extendida<\/strong> para aplicaciones severas<\/p><\/li><li><p><strong>\u03a0\u03bb\u03ae\u03c1\u03b7 <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/troubleshoot-optical-transceivers-digital-diagnostic-monitoring\/\"><strong>DDM\/DOM<\/strong><\/a><strong> compatibilidad<\/strong> para facilitar el diagn\u00f3stico<\/p><\/li><li><p><strong>\u03a7\u03b1\u03bc\u03b7\u03bb\u03cc <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/el\/knowledge-center\/how-to-reduce-jitter-in-optical-networks-for-stability\/\"><strong>jiter<\/strong><\/a><strong> y potencia \u00f3ptica estable<\/strong> para implementaciones en telecomunicaciones y centros de datos<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Estas caracter\u00edsticas ayudan a los integradores a mantener una mayor disponibilidad de la red y reducir el tiempo de resoluci\u00f3n de problemas en redes \u00f3pticas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El fallo de TX y la p\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS) son mecanismos de diagn\u00f3stico esenciales en los transceptores \u00f3pticos modernos.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Fallo de transmisi\u00f3n (TX Fault)<\/strong> indica problemas en el transmisor.<\/p><\/li><li><p><strong>P\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS)<\/strong> indica potencia \u00f3ptica de entrada insuficiente o ausente.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Comprender sus causas, comportamientos y m\u00e9todos de soluci\u00f3n de problemas permite a los ingenieros de redes identificar r\u00e1pidamente los problemas y mantener una comunicaci\u00f3n fiable por fibra \u00f3ptica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para un rendimiento estable, una fiabilidad a largo plazo y una integridad \u00f3ptica s\u00f3lida de la se\u00f1al, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/\">LINK-PP<\/a> ofrece una gama completa de <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\">SFP<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\">SFP+<\/a>, \u03ba\u03b1\u03b9 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm?ca=1691&amp;cv=9216\">de grado industrial<\/a> transceptores \u00f3pticos adaptados para aplicaciones de redes globales.<\/p>","protected":false},"excerpt":{"rendered":"<p>Descubra c\u00f3mo afectan el fallo de transmisi\u00f3n (TX Fault) y la p\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS) a los transceptores \u00f3pticos. Esta gu\u00eda explica sus funciones, causas comunes y pasos pr\u00e1cticos para la soluci\u00f3n de problemas.<\/p>","protected":false},"author":1,"featured_media":3627,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[24,26],"class_list":["post-3628","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/3628","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/comments?post=3628"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/3628\/revisions"}],"predecessor-version":[{"id":10838,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/posts\/3628\/revisions\/10838"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media\/3627"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/media?parent=3628"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/categories?post=3628"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/el\/wp-json\/wp\/v2\/tags?post=3628"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}