{"id":5813,"date":"2025-07-11T00:00:00","date_gmt":"2025-07-11T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/what-is-the-difference-between-nrz-and-pam4\/"},"modified":"2026-06-22T09:06:48","modified_gmt":"2026-06-22T09:06:48","slug":"what-is-the-difference-between-nrz-and-pam4","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-the-difference-between-nrz-and-pam4","title":{"rendered":"NRZ vs. PAM4 \u2013 Verst\u00e4ndnis der wesentlichen Unterschiede"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c.webp\" alt=\"What is the difference between NRZ and PAM4?\" class=\"wp-image-5807\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/05091a803b6a4dbdbdb66f8a4b45136c-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Wesentliche Unterschiede zwischen PAM4 und NRZ<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Erforschen Sie die Modulationsunterschiede zwischen PAM4 und NRZ f\u00fcr moderne Netzwerke.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Funktion<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>NRZ (Non-Return-to-Zero)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>PAM4 (Pulsamplitudenmodulation mit 4 Stufen)<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Pegel<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2 (z.\u202fB. Niedrig = 0, Hoch = 1)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 (z.\u202fB. L0 = 00, L1 = 01, L2 = 10, L3 = 11)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Bits pro Symbol<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Datendurchsatz-Effizienz<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Geringer (Datendurchsatz = Symbolrate)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her (Datendurchsatz = 2 \u00d7 Symbolrate)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Symbolrate (Baud) bei gleicher Datenrate<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her (z.\u202fB. 56 GBaud f\u00fcr 56 Gbit\/s)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Geringer (z.\u202fB. 28 GBaud f\u00fcr 56 Gbit\/s)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Anf\u00e4lligkeit gegen\u00fcber Rauschen<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Geringer (gr\u00f6\u00dfere Augen\u00f6ffnung, h\u00f6here SNR-Marge)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her (kleinere Augen\u00f6ffnung, geringere SNR-Marge)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Implementierungskomplexit\u00e4t<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her (erfordert DSP, starke FEC)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Typischer Leistungsverbrauch pro Bit<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Geringer (ausgereifte Technologie)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her (Komplexit\u00e4tsaufwand)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Vorherrschende Datenraten<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2264 25 Gbit\/s pro Lane (z.\u202fB. 10G-, 25G-SFP+)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>\u2265 50 Gbit\/s pro Lane (z.\u202fB. 100G, 200G, 400G, 800G)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Wichtige Anwendungen<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Veraltete 10G-\/25G-Schnittstellen mit kurzer Reichweite<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hochgeschwindigkeitsrechenzentren (ab 100G), Hochleistungsrechnen (HPC), KI\/ML-Cluster, 5G-Fronthaul\/Midhaul<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Sie k\u00f6nnen sehen, wie sich Netzwerke rasch ver\u00e4ndern, da Rechenzentren mehr Geschwindigkeit ben\u00f6tigen. Die <strong>PAM4 vs. NRZ<\/strong> Debatte ist wichtig, weil PAM4 zwei Bits pro Symbol \u00fcbertr\u00e4gt, w\u00e4hrend NRZ nur ein Bit pro Symbol \u00fcbertr\u00e4gt. Diese \u00c4nderung verdoppelt die Bandbreitennutzung f\u00fcr neue Ethernet-Standards, ohne zus\u00e4tzliche Kanalbandbreite zu ben\u00f6tigen. In Rechenzentren spielt der Vergleich PAM4 vs. NRZ eine Rolle, weil PAM4 vier Amplitudenpegel verwendet, w\u00e4hrend NRZ nur zwei Pegel nutzt. Wenn Netzwerke schneller werden, erm\u00f6glicht die PAM4-Modulation eine schnellere und effizientere Daten\u00fcbertragung.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Wichtige Erkenntnisse<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>PAM4<\/strong> \u00fcbertr\u00e4gt zwei Bits pro Symbol. Sie nutzt vier Spannungspegel. Dadurch bewegt sich die Daten\u00fcbertragung doppelt so schnell wie bei NRZ. NRZ \u00fcbertr\u00e4gt nur ein Bit pro Symbol. Sie nutzt lediglich zwei Spannungspegel.<\/p><\/li><li><p><strong>NRZ<\/strong> besitzt st\u00e4rkere Signale. Sie weist weniger Rauschen auf und verbraucht weniger Leistung. Dadurch ist sie einfacher zu nutzen. Sie funktioniert besser f\u00fcr lange Entfernungen oder langsamere Netzwerke.<\/p><\/li><li><p>PAM4 eignet sich am besten f\u00fcr schnelle, kurze Verbindungen. Sie wird in 400G-Ethernet und Rechenzentren eingesetzt. Sie erfordert spezielle Fehlerkorrektur. Zudem verbraucht sie mehr Leistung.<\/p><\/li><li><p>Sie w\u00e4hlen PAM4 oder NRZ je nach Ihren Netzwerk-Anforderungen aus. Ber\u00fccksichtigen Sie Geschwindigkeit, Reichweite, Kosten und zuk\u00fcnftige Anforderungen.<\/p><\/li><li><p>Die Verwendung sowohl von PAM4 als auch von NRZ in einem Netzwerk kann hilfreich sein. Sie bietet ein Gleichgewicht zwischen Geschwindigkeit und Zuverl\u00e4ssigkeit und unterst\u00fctzt zudem die Vorbereitung auf zuk\u00fcnftige Upgrades.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Grundlagen der Modulation<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Was ist NRZ?<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"486\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1.webp\" alt=\"NRZ encoding\" class=\"wp-image-5808\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1-300x122.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1-1024x415.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1-768x311.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ce3795470145420dba9b9d02e500e6f1-18x7.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-non-return-to-zero-in-digital-communication\/\"><strong>NRZ<\/strong><\/a> ist eine einfache Methode zur Signal\u00fcbertragung. Sie steht f\u00fcr <strong>Non-Return-to-Zero<\/strong>. Bei dieser Methode werden zwei Spannungswerte zur Darstellung bin\u00e4rer Daten verwendet: Eine \u20181\u2019 entspricht einer hohen Spannung, eine \u20180\u2019 einer niedrigen Spannung. Das Signal kehrt zwischen den Bits nicht auf Null zur\u00fcck \u2013 dies sorgt f\u00fcr einfache Verst\u00e4ndlichkeit. Bei unipolarem NRZ entspricht die \u20181\u2019 einer positiven Spannung und die \u20180\u2019 einer Spannung von Null Volt; bei bipolarem NRZ wechselt das Signal zwischen positiver und negativer Spannung. <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>Zwei Pegel:<\/strong> Es werden zwei unterschiedliche Spannungs- (elektrisch) oder Lichtintensit\u00e4tspegel (optisch) verwendet.<\/p><ul><li><p style=\"margin: 0px;\">Ein hoher Pegel stellt typischerweise eine logische \u20181\u2019 dar.<\/p><\/li><li><p style=\"margin: 0px;\">Ein niedriger Pegel stellt eine logische \u20180\u2019 dar.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Einfache Funktionsweise:<\/strong> In jeder Symbolperiode wird entweder eine \u20181\u2019 oder eine \u20180\u2019 \u00fcbertragen. Das Signal kehrt zwischen Bits mit demselben Wert nicht in einen neutralen \u201cNull\u201d-Zustand zur\u00fcck (daher \u201cNon-Return-to-Zero\u201d).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Vorteile:<\/strong> Die Einfachheit macht NRZ robust und relativ einfach zu implementieren, mit geringerem Stromverbrauch und weniger komplexen Anforderungen an die Signalverarbeitung. Bei niedrigeren Datenraten bietet es ausgezeichnete Signalintegrit\u00e4t.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Einschr\u00e4nkungen:<\/strong> Ihre Effizienz st\u00f6\u00dft jedoch an Grenzen: Um die Datenrate zu verdoppeln, muss die Symbolrate (Baudrate) verdoppelt werden. Eine Verdopplung der Baudrate f\u00fchrt signifikant zu st\u00e4rkerer Signalverschlechterung durch Kanalverluste, Rauschen und \u00dcbersprechen \u2013 was sie f\u00fcr Mainstream-Anwendungen jenseits von ca. 25\u201328 Gigabaud pro Lane praktisch unm\u00f6glich macht.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Was ist PAM4?<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"516\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b.webp\" alt=\"PAM4 encoding\" class=\"wp-image-5809\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b-300x129.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b-1024x440.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b-768x330.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/8766e10c7cab415784322b28ebf4f58b-18x8.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong><\/a> ist eine Methode, mehr Daten gleichzeitig zu \u00fcbertragen. Sie steht f\u00fcr <strong>Pulse-Amplitude-Modulation mit vier Pegeln<\/strong>. Dabei werden vier Spannungspegel verwendet, um jeweils zwei Bits pro Symbol darzustellen. Dadurch l\u00e4sst sich doppelt so viel Datenmenge wie bei NRZ innerhalb derselben Zeit \u00fcbertragen. PAM4 ist eine Form der Pulsamplitudenmodulation, die die Bandbreitennutzung verbessert. Jedes Symbol in PAM4 repr\u00e4sentiert ein Bitpaar \u2013 also 00, 01, 10 oder 11 \u2013 und erm\u00f6glicht so eine h\u00f6here Daten\u00fcbertragung ohne zus\u00e4tzlichen Bedarf an Kanalbandbreite.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Vier Pegel:<\/strong> PAM4 verwendet <em>vier<\/em> unterschiedliche Spannungs- oder Lichtintensit\u00e4tspegel.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Zwei Bits pro Symbol:<\/strong> Jede Symbolperiode \u00fcbertr\u00e4gt nun <em>zwei<\/em> Bits an Information:<\/p><ul><li><p style=\"margin: 0px;\">Pegel 0: \u201900\u2019<\/p><\/li><li><p style=\"margin: 0px;\">Stufe 1: \u201901\u2019<\/p><\/li><li><p style=\"margin: 0px;\">Stufe 2: \u201910\u2019<\/p><\/li><li><p style=\"margin: 0px;\">Stufe 3: \u201911\u2019<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Verdopplung der Effizienz:<\/strong> Durch die \u00dcbertragung von zwei Bits pro Symbol erreicht PAM4 die doppelte Datenrate von NRZ <em>bei derselben Baudrate<\/em>. Ein 28-Gigabaud-PAM4-Signal liefert 56 Gigabit pro Sekunde (Gbps) pro Lane, w\u00e4hrend NRZ bei dieser Baudrate nur 28 Gbps liefern w\u00fcrde.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Herausforderungen:<\/strong> Diese Effizienz hat ihren Preis:<\/p><ul><li><p style=\"margin: 0px;\"><strong>Vermindertes Signal-Rausch-Verh\u00e4ltnis (SNR):<\/strong> Die vier Pegel liegen enger beieinander als die beiden Pegel von NRZ. Dadurch wird das Signal viel anf\u00e4lliger f\u00fcr Rauschen, Verzerrung und St\u00f6rungen. Eine geringere Rauschmarke kann einen Pegel umkippen und Fehler verursachen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Erh\u00f6hte Komplexit\u00e4t:<\/strong> PAM4 erfordert deutlich anspruchsvollere Transceiver-Designs, darunter leistungsstarke <strong>Vorw\u00e4rtsfehlerkorrektur (FEC)<\/strong>, fortschrittliche <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/digital-signal-processor-functionality-in-optical-transceivers\/\"><strong>DSP (Digitale Signalverarbeitung)<\/strong><\/a>, sowie pr\u00e4zise Linearit\u00e4t in Treibern und Empf\u00e4ngern. Dies f\u00fchrt im Allgemeinen zu einem h\u00f6heren Stromverbrauch pro Bit im Vergleich zu ausgereiften NRZ-Designs.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Hinweis: PAM4 weist mehr Spannungspegel auf, weshalb der Abstand zwischen ihnen geringer ist. Dadurch sind PAM4-Signale anf\u00e4lliger f\u00fcr St\u00f6rungen durch Rauschen als NRZ-Signale.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Warum Modulation wichtig ist<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/what-is-optical-modulation-and-how-it-works-explained\/\"><strong>Modulation<\/strong><\/a> wird ben\u00f6tigt, um digitale Daten \u00fcber Kabel oder Glasfaser zu senden. Sie ver\u00e4ndert das Signal so, dass es \u00fcber gr\u00f6\u00dfere Entfernungen mit weniger Problemen \u00fcbertragen werden kann. F\u00fcr hohe Datenraten unterst\u00fctzen externe Modulationswerkzeuge \u2013 wie ein Mach-Zehnder-Modulator \u2013 die Signalst\u00e4rke. Die Pulsamplitudenmodulation und andere Methoden zur Signalanpassung helfen dabei, die optimale Balance aus Geschwindigkeit, Effizienz und Zuverl\u00e4ssigkeit zu finden.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Augendiagramme und Signalintegrit\u00e4t<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >NRZ-Augendiagramm<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"659\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e.webp\" alt=\"NRZ eye diagram\" class=\"wp-image-5810\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e-300x165.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e-1024x562.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e-768x422.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e1f1ed087d5b4594a6e4af41382f1e6e-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Sie sich ein <strong>NRZ-Augendiagramm<\/strong>, ansehen, erkennen Sie, wie das Signal funktioniert. Es gibt zwei Hauptspannungspegel, einen f\u00fcr 0 und einen f\u00fcr 1. Dadurch entsteht im Diagramm eine gro\u00dfe, offene \u201cAugen\u201d-Form. Das offene Auge bedeutet, dass das Signal stark ist und nicht leicht durch Rauschen gest\u00f6rt wird.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Sie erkennen zwei klare Spannungspegel, sodass sich 0 und 1 leicht unterscheiden lassen.<\/p><\/li><li><p>Die breite Augen\u00f6ffnung zeigt an, dass das Signal stark ist und nur wenig ver\u00e4ndert wird.<\/p><\/li><li><p>Glatte \u00dcberg\u00e4nge zwischen den Pegeln erleichtern die Zeitsteuerung und reduzieren Fehler.<\/p><\/li><li><p>Der hohe Teil des Auges zeigt, wie viel Rauschen das Signal verkraften kann.<\/p><\/li><li><p>Der breite Teil zeigt, ob Zeitjitter oder Inter-Symbol-Interferenz vorliegen.<\/p><\/li><li><p>Ein gr\u00f6\u00dferes Augendiagramm bedeutet weniger Fehler und einfachere Taktsynchronisation.<\/p><\/li><li><p>Wenn das Augendiagramm kleiner wird, verschlechtern Rauschen oder Probleme das Signal.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">NRZ-Augendiagramme sind einfach und nicht so komplex wie PAM4. Dadurch ist NRZ robuster und einfacher zu nutzen, wenn Datensicherheit im Vordergrund steht.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >PAM4 Augendiagramm<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"602\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6.webp\" alt=\" PAM4 eye diagram\" class=\"wp-image-5811\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6-300x151.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6-1024x514.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6-768x385.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c1f23795d5d84753b9dee268ead913e6-18x9.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>PAM4-Augendiagramm<\/strong> unterscheidet sich vom NRZ-Augendiagramm: Hier sind vier verschiedene Pegelstufen statt nur zwei zu erkennen. Jede Stufe repr\u00e4sentiert ein anderes Zweibit-Paar. Die Pegel liegen eng beieinander, wodurch die Augen\u00f6ffnungen kleiner und \u00fcbereinander angeordnet sind. Dies macht das PAM4-Signal anf\u00e4lliger gegen\u00fcber Rauschen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wie zu erkennen ist, bedeuten die kleineren Augen\u00f6ffnungen bei PAM4 eine geringere Rauschtoleranz. Die Taktsynchronisation ist schwieriger, da die Augen nicht so gro\u00df sind. Bei zu starkem Rauschen k\u00f6nnen die \u00fcbereinanderliegenden Augen ineinanderflie\u00dfen, was zu mehr Fehlern f\u00fchrt. Zur Fehlerkorrektur und Aufrechterhaltung einer klaren PAM4-Signalqualit\u00e4t sind spezielle Werkzeuge erforderlich.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bei einem Vergleich ergibt sich, dass NRZ ein saubereres und gr\u00f6\u00dferes Augendiagramm liefert. PAM4 erm\u00f6glicht zwar h\u00f6here Datenraten, erfordert aber sorgf\u00e4ltige Signal\u00fcberwachung und zus\u00e4tzliche Ma\u00dfnahmen, um die Fehlerquote niedrig zu halten.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Wo kommen sie zum Einsatz? Anwendungsschwerpunkte<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>NRZ:<\/strong> Beh\u00e4lt nach wie vor die Spitzenposition bei Anwendungen, bei denen Einfachheit, Energieeffizienz und Kosteneffizienz f\u00fcr Datenraten \u2264 25 Gbit\/s pro Lane entscheidend sind. Dazu z\u00e4hlen beispielsweise 10-Gigabit-Ethernet (10GbE), 25-Gigabit-Ethernet (25GbE) in Serververbindungen sowie Legacy-Systeme. Viele <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Optischer Transceiver<\/strong><\/a> Typen wie <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\"><strong>SFP+<\/strong><\/a> (10G\/25G) und <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>QSFP28<\/strong><\/a> (4\u00d725G = 100G) nutzen NRZ.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>PAM4:<\/strong> Ist der unangefochtene Champion f\u00fcr hochdichte, breitbandige Anwendungen mit Anforderungen ab 50 Gbit\/s pro Lane und dar\u00fcber hinaus. Es bildet die Grundlage f\u00fcr:<\/p><ul><li><p style=\"margin: 0px;\">100-Gigabit-Ethernet (100GbE \u2013 mit 2 Lanes \u00e0 50G PAM4)<\/p><\/li><li><p style=\"margin: 0px;\">200-Gigabit-Ethernet (200GbE \u2013 4\u00d750G PAM4)<\/p><\/li><li><p style=\"margin: 0px;\">400-Gigabit-Ethernet (400GbE \u2013 8\u00d750G PAM4 oder 4\u00d7100G PAM4)<\/p><\/li><li><p style=\"margin: 0px;\">800-Gigabit-Ethernet (800GbE \u2013 8\u00d7100G PAM4)<\/p><\/li><li><p style=\"margin: 0px;\">KI-\/ML-Cluster und Hochleistungsrechner-(HPC-)Verbindungen.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Auswahl zwischen PAM4 und NRZ<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Sie zwischen PAM4 und NRZ w\u00e4hlen, sollten Sie einige wichtige Aspekte ber\u00fccksichtigen. Jede Technologie eignet sich f\u00fcr unterschiedliche Anwendungen. W\u00e4hlen Sie diejenige, die Ihren Anforderungen hinsichtlich Geschwindigkeit, Kosten und zuk\u00fcnftigem Netzwerk-Wachstum am besten entspricht.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hier sind einige wesentliche Aspekte, die Sie ber\u00fccksichtigen sollten:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Geschwindigkeitsanforderungen<\/strong>: Wenn Ihr Netzwerk extrem hohe Geschwindigkeiten ben\u00f6tigt, beispielsweise 400 G oder mehr, kann PAM4 doppelt so viel Datenmenge innerhalb desselben Zeitraums \u00fcbertragen. NRZ eignet sich besser f\u00fcr langsamere Netzwerke, die nicht so hohe Geschwindigkeiten erfordern.<\/p><\/li><li><p><strong>Signalqualit\u00e4t<\/strong>: NRZ verf\u00fcgt \u00fcber zwei Spannungspegel und ist daher st\u00f6rsicherer. Dadurch treten weniger Fehler auf und das Signal ist klarer. PAM4 nutzt vier Pegel, wodurch St\u00f6rungen das Signal st\u00e4rker beeintr\u00e4chtigen k\u00f6nnen. F\u00fcr PAM4 sind spezielle Werkzeuge zur Fehlerkorrektur erforderlich.<\/p><\/li><li><p><strong>Hardware und Kosten<\/strong>: NRZ-Komponenten sind einfach aufgebaut und kosteng\u00fcnstiger. PAM4 erfordert mehr Komponenten sowie spezielle Chips und ist daher teurer. Wenn Sie Kosten sparen und die Komplexit\u00e4t gering halten m\u00f6chten, ist NRZ eine sinnvolle Wahl.<\/p><\/li><li><p><strong>Stromverbrauch<\/strong>: NRZ verbraucht weniger Energie, da keine zus\u00e4tzliche Verarbeitung notwendig ist. PAM4 ben\u00f6tigt mehr Energie, um das Signal klar zu halten.<\/p><\/li><li><p><strong>Entfernung<\/strong>: NRZ eignet sich besser f\u00fcr lange \u00dcbertragungsstrecken. PAM4 ist optimal f\u00fcr kurze Verbindungen, beispielsweise innerhalb eines Rechenzentrums.<\/p><\/li><li><p><strong>Zuk\u00fcnftiges Wachstum<\/strong>: Wenn Sie Ihre Netzwerkgeschwindigkeit sp\u00e4ter steigern m\u00f6chten, kann PAM4 h\u00f6here Geschwindigkeiten und neue Standards bew\u00e4ltigen.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Unterschiede werden in der folgenden Tabelle deutlich:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Kriterium<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>NRZ-Eigenschaften<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>PAM4-Eigenschaften<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Datenrate<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1 Bit pro Taktzyklus<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2 Bits pro Taktzyklus (doppelte Bandbreite)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Signal-Rausch-Verh\u00e4ltnis<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her, weniger st\u00f6ranf\u00e4llig<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Niedriger, st\u00f6ranf\u00e4lliger<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>Bitfehlerrate (BER)<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her, erfordert Fehlerkorrektur<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Hardware-Komplexit\u00e4t<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Einfach, kosteneffizient<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Komplex, h\u00f6here Kosten<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Stromverbrauch<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>\u00dcbertragungsreichweite<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>L\u00e4nger<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>K\u00fcrzer<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Skalierbarkeit<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Gut f\u00fcr aktuelle Anforderungen<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Bereit f\u00fcr zuk\u00fcnftige Upgrades<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>\ud83d\udca1 <strong>Tip:<\/strong> W\u00e4hlen Sie NRZ, wenn Sie eine einfache und kosteng\u00fcnstige L\u00f6sung f\u00fcr langsamere Geschwindigkeiten oder l\u00e4ngere Strecken ben\u00f6tigen. Entscheiden Sie sich f\u00fcr PAM4, wenn Sie maximale Geschwindigkeit ben\u00f6tigen und Ihr Netzwerk zuk\u00fcnftig skalierbar sein soll.<\/p><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 LINK-PP-Optische Transceiver: Leistung mit NRZ und PAM4<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630.webp\" alt=\"LINK-PP\" class=\"wp-image-5812\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630-300x169.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630-1024x576.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630-768x432.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/99c1c5c4a1e24fe7ab4c7a9236a91630-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Die richtige Auswahl <strong>Optischer Transceiver<\/strong> ist entscheidend f\u00fcr die Netzwerkleistung. <strong>LINK-PP<\/strong> bietet ein umfassendes Portfolio, das sowohl NRZ als auch fortschrittliche PAM4-Modulation unterst\u00fctzt:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>F\u00fcr NRZ-Anwendungen:<\/strong> Zuverl\u00e4ssig und kosteneffizient <strong>Optischer Transceiver<\/strong> L\u00f6sungen wie unsere <strong>LINK-PP SFP-25G-SR <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473141.htm\"><strong>LS-MM8525-S1C<\/strong><\/a> or <strong>LINK-PP QSFP28-100G-SR4<br><\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>LQ-M85100-SR4C<\/strong><\/a> liefern robuste 25-Gbit\/s-Leistung pro Lane im NRZ-Format f\u00fcr 10G-, 25G- und 100G-(4\u00d725G)-Eins\u00e4tze.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>F\u00fcr Hochgeschwindigkeits-PAM4-Anwendungen:<\/strong> Unsere hochmoderne PAM4-Technologie <strong>Optischer Transceiver<\/strong> Module sind so konstruiert, dass sie die Herausforderungen an die Signalintegrit\u00e4t bew\u00e4ltigen:<\/p><ul><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/470377.htm\"><strong>LINK-PP LQD-CW400-DR4C:<\/strong><\/a> Ideal f\u00fcr 400G Kurzstrecken-Einmodenfaser mit 4\u00d7100G PAM4.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Optische Transceiver-Module von LINK-PP<\/strong><\/a> integrieren hochentwickelte DSP-Technologie und leistungsstarke FEC-Funktionen, um zuverl\u00e4ssige, hochperformante Konnektivit\u00e4t in anspruchsvollen PAM4-Umgebungen sicherzustellen \u2013 was sie zu einer zentralen Komponente f\u00fcr Rechenzentren und KI-Infrastrukturen der n\u00e4chsten Generation macht.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Die Zukunft ist mehrstufig<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">W\u00e4hrend NRZ nach wie vor unverzichtbar bleibt, verl\u00e4uft die Entwicklung im Hochgeschwindigkeits-Netzwerk eindeutig in Richtung PAM4 und m\u00f6glicherweise sogar noch komplexerer Modulationsschemata (wie PAM8 oder PAM16), wenn wir uns der 1,6-Terabit-Ethernet-\u00c4ra und dar\u00fcber hinaus n\u00e4hern. Die F\u00e4higkeit von PAM4, die Datenrate zu verdoppeln, ohne die Baudrate zu verdoppeln, ist entscheidend, um bestehende Glasfaserinfrastrukturen optimal zu nutzen. Eine erfolgreiche Implementierung von PAM4 h\u00e4ngt von hochwertigen Komponenten und einer ausgefeilten <strong>Optischer Transceiver<\/strong> Konstruktion ab \u2013 genau hier \u00fcberzeugen Innovatoren wie LINK-PP.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bereit, Ihr Hochgeschwindigkeits-Netzwerk zu optimieren?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Das Verst\u00e4ndnis der Unterschiede zwischen NRZ und PAM4 ist grundlegend f\u00fcr das Design und das Management moderner, breitbandiger Netzwerke. Egal, ob Sie bestehende Infrastrukturen aufr\u00fcsten oder moderne KI-Cluster bereitstellen \u2013 die Wahl der richtigen Modulation und des richtigen <strong>Optischer Transceiver<\/strong> Partners ist entscheidend.<\/p>\n\n\n\n<div><div widgetid=\"3ef779ac451211f099380a58fbc66727\" format=\"embedded\" data-widget-id=\"3ef779ac451211f099380a58fbc66727\" data-mode=\"production.zh\" style=\"display: block;\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Was macht PAM4 im Vergleich zu NRZ f\u00fcr Hochgeschwindigkeitsdaten\u00fcbertragung besser?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mit PAM4 erreichen Sie die doppelte Datenrate, da zwei Bits pro Symbol \u00fcbertragen werden. NRZ \u00fcbertr\u00e4gt nur ein Bit pro Symbol. PAM4 eignet sich am besten, wenn Sie mehr Geschwindigkeit in Ihrem Netzwerk ben\u00f6tigen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Verbraucht PAM4 immer mehr Strom als NRZ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PAM4 ben\u00f6tigt in der Regel mehr Strom. Zus\u00e4tzliche Schaltkreise f\u00fcr Fehlerkorrektur und Signalverarbeitung werden eingesetzt. NRZ verbraucht weniger Strom, da es eine einfachere Konstruktion aufweist.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Welches Verfahren ist einfacher zu installieren \u2013 PAM4 oder NRZ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">NRZ ist einfacher zu installieren. Es nutzt einfache Hardware und erfordert weniger Abstimmung. PAM4 hingegen erfordert mehr Aufwand bei der Einrichtung und eine sorgf\u00e4ltige Konstruktion, um St\u00f6rungen und Fehler zu bew\u00e4ltigen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >K\u00f6nnen PAM4 und NRZ im selben Netzwerk eingesetzt werden?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ja, beide k\u00f6nnen kombiniert werden. NRZ wird f\u00fcr \u00e4ltere oder l\u00e4ngere Verbindungen verwendet, w\u00e4hrend PAM4 f\u00fcr neue, hochgeschwindigkeitsf\u00e4hige Verbindungen eingesetzt wird. Dadurch l\u00e4sst sich Ihr Netzwerk schrittweise modernisieren.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Welches Verfahren eignet sich besser f\u00fcr lange Distanzen \u2013 PAM4 oder NRZ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">NRZ eignet sich besser f\u00fcr lange Distanzen. Es bew\u00e4ltigt St\u00f6rungen effizient und erh\u00e4lt die Signalqualit\u00e4t klar. PAM4 ist f\u00fcr kurze bis mittlere Distanzen geeignet, wo h\u00f6here Geschwindigkeit erforderlich ist.<\/p>\n\n\n\n<script src=\"https:\/\/cdn.mylandingpages.co\/widgets\/platform\/platform.widget.js\" async=\"true\"><\/script>","protected":false},"excerpt":{"rendered":"<p>PAM4 vs. NRZ: Vergleichen Sie Datenraten, St\u00f6rfestigkeit und Effizienz, um die beste Modulation f\u00fcr Ihr Netzwerk und Ihre Rechenzentrums-Upgrades auszuw\u00e4hlen.<\/p>","protected":false},"author":1,"featured_media":5807,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[26],"class_list":["post-5813","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5813","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=5813"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5813\/revisions"}],"predecessor-version":[{"id":11381,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5813\/revisions\/11381"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/5807"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=5813"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=5813"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=5813"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}