{"id":5787,"date":"2025-07-21T00:00:00","date_gmt":"2025-07-21T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/qsfp28-100g-sr4-vs-lr4-100g-transceiver-comparison\/"},"modified":"2026-06-22T08:53:35","modified_gmt":"2026-06-22T08:53:35","slug":"qsfp28-100g-sr4-vs-lr4-100g-transceiver-comparison","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/products\/qsfp28-100g-sr4-vs-lr4-100g-transceiver-comparison","title":{"rendered":"QSFP28 100G SR4 vs. QSFP28 100G LR4: Auswahl des richtigen 100G-Transceivers"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa9910e271bb4d5983db24fcf190b1d6.webp\" alt=\"QSFP28 100G SR4 vs QSFP28 100G LR4\" class=\"wp-image-5784\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa9910e271bb4d5983db24fcf190b1d6.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa9910e271bb4d5983db24fcf190b1d6-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa9910e271bb4d5983db24fcf190b1d6-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa9910e271bb4d5983db24fcf190b1d6-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa9910e271bb4d5983db24fcf190b1d6-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"color: rgb(64, 64, 64);\">Der Einsatz von 100G-Ethernet ist f\u00fcr moderne Rechenzentren und Hochgeschwindigkeitsnetzwerke unerl\u00e4sslich, doch die Auswahl des richtigen Transceivers ist entscheidend. Das QSFP28-Formfaktor dominiert den 100G-Markt, wobei SR4 und LR4 zwei verbreitete Typen sind. Obwohl beide eine beeindruckende \u00dcbertragungsrate von 100 Gbit\/s bieten, unterscheiden sie sich signifikant hinsichtlich ihrer zugrundeliegenden Technologie, Einsatzszenarien und Kostenstrukturen. Ein Verst\u00e4ndnis der Unterschiede zwischen den <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/products\/qsfp28-100g-sr4-transceivers\/\"><strong>QSFP28-100G-SR4-Transceiver<\/strong><\/a><span style=\"color: rgb(64, 64, 64);\"> und die <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/products\/100g-lr4-transceiver-long-distance-high-speed-network-guide\/\"><strong>QSFP28-100G-LR4-Transceiver<\/strong><\/a><span style=\"color: rgb(64, 64, 64);\"> gew\u00e4hrleistet optimale Netzwerkleistung, Kosteneffizienz und zukunftssichere Skalierbarkeit. Dieser Leitfaden geht detailliert auf deren Spezifikationen und Anwendungsf\u00e4lle ein und unterst\u00fctzt Sie bei der Entscheidung, welcher <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>100G-Optikmoduls<\/strong><\/a><span style=\"color: rgb(64, 64, 64);\"> am besten zu Ihren Infrastruktur-Anforderungen passt, unter besonderer Hervorhebung zuverl\u00e4ssiger L\u00f6sungen wie <\/span><strong>LINK-PP-Transceiver<\/strong><span style=\"color: rgb(64, 64, 64);\">.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Verst\u00e4ndnis der Kern-Technologien<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px 0px 4px;\"><strong>QSFP28-100G-SR4-Transceiver:<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Uses <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/overview-of-vcsel\/\">VCSEL (Vertical Cavity Surface Emitting Laser)<\/a> Lasern mit einer Wellenl\u00e4nge von 850 nm.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Konzipiert f\u00fcr <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>Multimode-Faser (MMF)<\/strong><\/a>, speziell OM3 oder OM4.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Konnektivit\u00e4t:<\/strong> Verwendet einen MPO-12-\/MTP\u00ae-Stecker. \u00dcbertr\u00e4gt und empf\u00e4ngt \u00fcber 4 parallele Kan\u00e4le in jede Richtung (4\u00d725 G).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Hauptanwendungsgebiet:<\/strong> Kurzstrecken-Verbindungen mit hoher Dichte innerhalb eines Rechenzentrums oder zwischen benachbarten Racks (Top-of-Rack zu Aggregation-\/Spine-Switches).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>LINK-PP-Modellbeispiel:<\/strong> LINK-PP <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\">LQ-M85100-SR4C<\/a> (Konform mit der QSFP28-MSA, 100 m \u00fcber OM4).<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>QSFP28-100G-LR4-Transceiver:<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Uses <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/dfb-laser-definition\/\">DFB-Laser (Distributed Feedback)<\/a> mit vier LWDM-Wellenl\u00e4ngen (ca. 1295 nm, 1300 nm, 1305 nm, 1310 nm).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Konzipiert f\u00fcr <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>Einmodenfaser (SMF)<\/strong><\/a>, speziell OS2.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Konnektivit\u00e4t:<\/strong> Verwendet einen Standard-Duplex-LC-Stecker. Multiplext die vier Wellenl\u00e4ngen auf ein einzelnes Faserpaar <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/wdm-optical-transceiver-module-applications\/\">(WDM-Technologie)<\/a>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Hauptanwendungsgebiet:<\/strong> Langstrecken-Verbindungen zwischen Rechenzentren (DCI), Campus-Backbones, Netzen von Serviceprovidern sowie Metro-Zugangsnetzen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>LINK-PP-Modellbeispiel:<\/strong> LINK-PP <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\">LQ-LW100-LR4C<\/a> (Konform mit der QSFP28-MSA, bis zu 10 km \u00fcber SMF).<\/p><\/li><\/ul><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Direkter Vergleich: QSFP28 SR4 vs. LR4<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die folgende Tabelle fasst die wesentlichen Unterschiede zusammen:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Funktion<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>QSFP28-100G-SR4-Transceiver<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>QSFP28-100G-LR4-Transceiver<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Reach<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Bis zu 70 m (OM3)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Bis zu 10 km<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p\/><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Bis zu 100 m (OM4)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><em>(Standard-LR4-Spezifikation)<\/em><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fasertyp<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Multimode-Faser (OM3\/OM4)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Einmodus-Faser (OS2)<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Stecker<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>MPO-12\/MTP\u00ae<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>0\u00b0C bis +70\u00b0C<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Wellenl\u00e4nge<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>850\u202fnm (4 Kan\u00e4le)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>LWDM (4 Kan\u00e4le: ca. 1295\u20131310 nm)<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Lasertyp<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>VCSEL<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>DFB<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Modulation<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>NRZ<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>NRZ<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Typischer Energieverbrauch<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>~3,5 W<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>~3,5\u202fW \u2013 4,5\u202fW<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Relativer Kostenfaktor<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Lower<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>H\u00f6her<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Hauptanwendungsfall<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Rechenzentrum: Inter-Rack-Konnektivit\u00e4t, hochdichte Kurzstrecken<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Rechenzentrum-Interconnect (DCI), Campus-\/Metro-Netzwerke, Langstrecken<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Wichtiger Vorteil<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kosteng\u00fcnstig f\u00fcr kurze Strecken, nutzt vorhandene Multimode-Faserkabel (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Langstrecken\u00fcbertragung \u00fcber Singlemode-Faser (SMF), Kompatibilit\u00e4t mit Standard-Duplex-LC-Steckern<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Wichtige Unterschiede erl\u00e4utert<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px;\"><strong>Reichweite &amp; Fasertyp:<\/strong> Dies ist der bedeutendste Unterschied. <strong>SR4 ist ausschlie\u00dflich f\u00fcr kurze Entfernungen vorgesehen<\/strong> innerhalb eines Rechenzentrums unter Verwendung von Multimode-Faser (MMF). <strong>LR4 \u00fcberzeugt bei Entfernungen bis zu 10 km<\/strong> \u00fcber Einmodenfaser (SMF). Die falsche Wahl <strong>Glasfasermodul<\/strong> f\u00fcr Ihre Entfernungsanforderung f\u00fchrt zum Linkausfall.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Stecker &amp; Verkabelung:<\/strong> SR4 erfordert MPO\/MTP\u00ae-abgeschlossene MMF-Leitungen (h\u00e4ufig mit 8 oder 12 Fasern). LR4 verwendet Standard-LC-Duplex-Patchkabel auf SMF und bietet damit eine einfachere Kabelverwaltung sowie die Nutzung der weit verbreiteten LC-Infrastruktur.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Technologie &amp; Kosten:<\/strong> SR4 nutzt einfachere VCSEL-Laser und parallele Optik \u00fcber MMF und ist daher im Allgemeinen <strong>kosteng\u00fcnstiger<\/strong> f\u00fcr kurze Reichweiten kosteng\u00fcnstiger. LR4 setzt komplexere WDM-Optik und DFB-Laser auf SMF ein, was den Preis erh\u00f6ht, jedoch lange Reichweiten erm\u00f6glicht.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Leistungsaufnahme &amp; W\u00e4rmeentwicklung:<\/strong> Obwohl beide Module innerhalb des QSFP28-Leistungsprofils liegen, verbrauchen LR4-Module oft geringf\u00fcgig mehr Leistung (insbesondere bei Temperatur- und Entfernungsvariationen) als SR4-Module. Ber\u00fccksichtigen Sie das thermische Design bei dicht best\u00fcckten Chassis.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Anwendungsschwerpunkt:<\/strong> SR4 ist der Arbeitstier f\u00fcr <strong>100G-Intra-Rechenzentrum-Verbindungen<\/strong>. LR4 ist unverzichtbar f\u00fcr <strong>die Verbindung geografisch getrennter Standorte<\/strong> oder lange Campus-Strecken.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 So w\u00e4hlen Sie zwischen QSFP28 100G SR4 und QSFP28 100G LR4 Transceiver<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fab80848a938443ab616482fc9181cc5.webp\" alt=\"QSFP28 100G SR4 vs QSFP28 100G LR4\" class=\"wp-image-5785\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fab80848a938443ab616482fc9181cc5.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fab80848a938443ab616482fc9181cc5-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fab80848a938443ab616482fc9181cc5-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fab80848a938443ab616482fc9181cc5-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/fab80848a938443ab616482fc9181cc5-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Wann Sie QSFP28 100G SR4 w\u00e4hlen sollten<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Sie m\u00fcssen Switches innerhalb desselben Racks oder benachbarter Racks verbinden.<\/p><\/li><li><p style=\"margin: 0px;\">Ihre vorhandene Verkabelungsinfrastruktur besteht aus OM3- oder OM4-Multimode-Faser.<\/p><\/li><li><p style=\"margin: 0px;\">Ihre Verbindungsstrecken betragen <strong>100 Meter oder weniger<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\">Eine Kostenoptimierung f\u00fcr hochdichte, kurzreichweitige Einsatzszenarien ist entscheidend.<\/p><\/li><li><p style=\"margin: 0px;\">Sie ben\u00f6tigen Kompatibilit\u00e4t mit <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>100G SR4-Optikmodulen<\/strong><\/a> f\u00fcr ToR-(Top-of-Rack-)Aggregation.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Wann Sie QSFP28 100G LR4 w\u00e4hlen sollten<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Sie m\u00fcssen Switches zwischen verschiedenen Geb\u00e4uden oder Rechenzentren verbinden.<\/p><\/li><li><p style=\"margin: 0px;\">Ihre vorhandene Verkabelungsinfrastruktur besteht aus OS2-Einmodenfaser.<\/p><\/li><li><p style=\"margin: 0px;\">Ihre Verbindungsstrecken betragen <strong>zwischen 100 m und 10 km<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\">Sie ben\u00f6tigen die Flexibilit\u00e4t und Zukunftssicherheit einer SMF-Infrastruktur.<\/p><\/li><li><p style=\"margin: 0px;\">Sie ben\u00f6tigen Kompatibilit\u00e4t mit Standard-LC-Verteilern und -Verkabelung f\u00fcr <strong>100G-Verbindungen \u00fcber lange Strecken<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Warum LINK-PP 100G-Transceiver w\u00e4hlen?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5785e84c332e475cac61c9fee40c03a5.webp\" alt=\"100G Optical Transceivers\" class=\"wp-image-5786\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5785e84c332e475cac61c9fee40c03a5.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5785e84c332e475cac61c9fee40c03a5-300x169.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5785e84c332e475cac61c9fee40c03a5-1024x576.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5785e84c332e475cac61c9fee40c03a5-768x432.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5785e84c332e475cac61c9fee40c03a5-18x10.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>LINK-PP<\/strong> bietet leistungsstarke, MSA-konforme <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>100G-QSFP28-Module<\/strong><\/a>, darunter sowohl SR4- als auch LR4-Varianten, streng auf Interoperabilit\u00e4t und Zuverl\u00e4ssigkeit getestet. Unsere Optikmodule bieten:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Kosteneinsparungen:<\/strong> Deutliche Einsparungen im Vergleich zu OEM-Modulen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Garantierte Kompatibilit\u00e4t:<\/strong> Umfangreiche Tests gew\u00e4hrleisten einen nahtlosen Betrieb mit f\u00fchrenden Switch-Marken (Cisco, Juniper, Arista, Dell, HPE usw.).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Qualit\u00e4t &amp; Zuverl\u00e4ssigkeit:<\/strong> Strenge Qualit\u00e4tskontrollprozesse gew\u00e4hrleisten niedrige Ausfallraten und langfristige Leistungsf\u00e4higkeit.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Lebenslange Garantie und Support:<\/strong> Unterst\u00fctzt durch fachkundigen technischen Support. <strong>Aktualisieren Sie Ihre Netzwerkinfrastruktur heute kosteneffizient mit zuverl\u00e4ssigen LINK-PP-Optikmodulen.<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>ben\u00f6tigen \u2013 LINK-PP bietet streng gepr\u00fcfte L\u00f6sungen, die Leistung und Langlebigkeit garantieren, oft zu einem Bruchteil der OEM-Kosten.<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choosing between a <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>QSFP28 100G SR4<\/strong><\/a> and a <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\"><strong>QSFP28-100G-LR4-Transceiver<\/strong><\/a> reduziert sich auf zwei grundlegende Faktoren: <strong>erforderliche \u00dcbertragungsentfernung<\/strong> et <strong>vorhandener Typ der Glasfaserkabel<\/strong>. F\u00fcr kosteng\u00fcnstige, hochdichte Verbindungen innerhalb von 100 Metern unter Nutzung von Multimode-Glasfaser ist das <strong>SR4-Optikmodul<\/strong> die klare Wahl. F\u00fcr vielseitige Langstreckenverbindungen bis zu 10 Kilometern \u00fcber Singlemode-Glasfaser ist der <strong>LR4-Transceiver<\/strong> unverzichtbar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Das Verst\u00e4ndnis dieser Unterschiede stellt sicher, dass Sie in die richtige <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>100G-Glasfasersender-Empf\u00e4nger-Technologie<\/strong><\/a> investieren und sowohl Leistung als auch Budget optimieren. Kompromittieren Sie nicht die Zuverl\u00e4ssigkeit Ihrer kritischen 100G-Verbindungen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bereit, zuverl\u00e4ssige Hochleistungs-100G-Konnektivit\u00e4t einzusetzen?<\/strong><br\/><strong>Erkunden Sie noch heute das umfangreiche Sortiment an MSA-konformen QSFP28 100G SR4- und LR4-Transceivern von LINK-PP. <\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/message.htm\"><strong>Angebot anfordern \u279e<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/support.htm\"><strong>Technischer Support \u279e<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 FAQ: QSFP28 100G SR4 vs. LR4<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>F: Kann ich einen SR4-Transceiver \u00fcber Einmodenfaser (Single-Mode Fiber, SMF) verwenden?<\/strong><br\/><strong>A: Nein, auf keinen Fall.<\/strong> SR4 ist konzipiert <em>only<\/em> f\u00fcr Multimodefaser (OM3\/OM4). Der Versuch, ihn \u00fcber SMF einzusetzen, f\u00fchrt entweder sofort zum Ausfall oder verursacht schwerwiegende Fehler. Passen Sie stets den <strong>optischen Modultyp<\/strong> an den Fasertyp an.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>F: Kann ich einen LR4-Transceiver \u00fcber Multimodefaser (MMF) verwenden?<\/strong><br\/><strong>A: Nein.<\/strong> LR4 erfordert Einmodenfaser (OS2). Der Einsatz \u00fcber MMF erreicht weder die erforderliche Reichweite noch die erforderliche Leistung.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>F: Was ist die maximale Reichweite f\u00fcr QSFP28 LR4?<\/strong><br\/><strong>A:<\/strong> Die Standard-Spezifikation f\u00fcr QSFP28 100G LR4 lautet <strong>bis zu 10 Kilometer<\/strong> \u00fcber OS2-Einmodenfaser. Stellen Sie sicher, dass Ihr optisches Budget (Link-D\u00e4mpfung) die gew\u00fcnschte Reichweite unterst\u00fctzt.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>F: Sind SR4- und LR4-Transceiver miteinander interoperabel?<\/strong><br\/><strong>A:<\/strong> Nein, sie sind nicht direkt miteinander interoperabel. Ein SR4-Modul muss mit einem anderen SR4-Modul \u00fcber MMF verbunden werden. Ein LR4-Modul muss mit einem anderen LR4-Modul \u00fcber SMF verbunden werden. Sie nutzen grundlegend unterschiedliche optische Technologien und Lichtwege.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>F: Wie sieht es mit ER4- oder ZR4-Modulen aus?<\/strong><br\/><strong>A:<\/strong> Dies sind Varianten f\u00fcr noch gr\u00f6\u00dfere Entfernungen als LR4. ER4 erreicht typischerweise ~40 km, ZR4 ~80 km. Sie verbrauchen deutlich mehr Leistung und sind teurer als LR4. LR4 (10 km) deckt den weitaus gr\u00f6\u00dften Teil der Anforderungen im Campus- und Metro-DCI-Bereich ab.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Siehe auch<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/products\/100g-lr4-transceiver-long-distance-high-speed-network-guide\/\">Verst\u00e4ndnis des 100G-LR4-Transceivers f\u00fcr moderne Netzwerke<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/products\/qsfp28-100g-sr4-transceivers\/\">Entschlie\u00dfen Sie sich f\u00fcr den Hochgeschwindigkeits-LINK-PP-QSFP28-100G-SR4-Transceiver \u2013 LQ-M85100-SR4C<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-optical-transceiver-form-factors-guide\/\">Ein umfassender Leitfaden zu Formfaktoren f\u00fcr 100-Gbit\/s-Optik-Transceiver-Module<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/products\/link-pp-100g-transceivers-connectivity\/\">Warum LINK-PP-100G-Transceiver f\u00fcr Hochgeschwindigkeitsverbindungen w\u00e4hlen?<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Vergleichen Sie QSFP28 100G SR4 und QSFP28 100G LR4, um den richtigen 100G-Transceiver f\u00fcr Ihr Netzwerk basierend auf Reichweite, Fasertyp, Steckverbindern und Budget auszuw\u00e4hlen.<\/p>","protected":false},"author":1,"featured_media":5784,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[28],"tags":[13],"class_list":["post-5787","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5787","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=5787"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5787\/revisions"}],"predecessor-version":[{"id":11316,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5787\/revisions\/11316"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/5784"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=5787"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=5787"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=5787"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}