{"id":5439,"date":"2025-08-15T00:00:00","date_gmt":"2025-08-15T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/100g-single-fiber-qsfp28-modern-network-upgrades-data-centers\/"},"modified":"2026-06-22T08:26:22","modified_gmt":"2026-06-22T08:26:22","slug":"100g-single-fiber-qsfp28-modern-network-upgrades-data-centers","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-single-fiber-qsfp28-modern-network-upgrades-data-centers","title":{"rendered":"Verst\u00e4ndnis des 100G-Einzel-Faser-QSFP28-Moduls f\u00fcr moderne Netzwerke"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39a06fb1f0804aeb9850d6a9572c4115.webp\" alt=\"Understanding 100G Single Fiber QSFP28 for Modern Networks\" class=\"wp-image-5437\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39a06fb1f0804aeb9850d6a9572c4115.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39a06fb1f0804aeb9850d6a9572c4115-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39a06fb1f0804aeb9850d6a9572c4115-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39a06fb1f0804aeb9850d6a9572c4115-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39a06fb1f0804aeb9850d6a9572c4115-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">Da die Bandbreitenanforderungen explodieren, <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><span class=\"qc-p1-tag\"><strong>100G-QSFP28-Module<\/strong><\/span><\/a><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> sind zu der Grundlage moderner Rechenzentren und 5G-Netzwerke geworden. Doch herk\u00f6mmliche Zweifaser-L\u00f6sungen erfordern die doppelte Menge an Faserverkabelung, was Kosten und Komplexit\u00e4t steigert. Hier kommen <\/span><span class=\"qc-p1-tag\"><strong>Einzelfaser-QSFP28-Module<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">\u2014eine bahnbrechende Innovation, die <\/span><span class=\"qc-p1-tag\"><strong>BiDi (Bidirektional)<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> Technologie nutzt, um 100-Gbit\/s-Daten \u00fcber <\/span><span class=\"qc-p1-tag\"><em>ein einziger Faserstrang<\/em><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">. zu \u00fcbertragen. Durch den Einsatz unterschiedlicher Wellenl\u00e4ngen (z.\u202fB. 1271\u202fnm\/1331\u202fnm) f\u00fcr Upstream- bzw. Downstream-Verkehr senken diese Module die Kosten f\u00fcr die Glasfaserinfrastruktur um 50\u202f%, w\u00e4hrend sie volle 100-Gbit\/s-Leistung beibehalten.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u27a4 So funktioniert der 100-Gbit\/s-Einzelglasfaser-Transceiver (das BiDi-Prinzip)<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Im Gegensatz zu Standard- <strong>Duplex-Transceiver<\/strong> ben\u00f6tigen zwei Glasfasern (eine f\u00fcr Tx, eine f\u00fcr Rx), <strong>Einzelfaser-Module<\/strong> Verwendung <strong>Wellenl\u00e4ngenmultiplexierung <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/wdm-optical-transceiver-module-applications\/\"><strong>(WDM)<\/strong><\/a>. Sie nutzen zwei verschiedene Lichtwellenl\u00e4ngen (Farben):<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Senden (Tx):<\/strong> Senden Daten mit einer bestimmten Wellenl\u00e4nge (z.\u202fB. 1271\u202fnm).<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Empfangen (Rx):<\/strong> Empfangen eingehende Daten auf einer <em>different<\/em> anderen Wellenl\u00e4nge (z.\u202fB. 1331\u202fnm).<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Ein spezieller Filter <strong>(WDM-Koppler)<\/strong> im Modul kombiniert und trennt diese Signale auf dem einzelnen Glasfaserstrang. Diese <strong>Bidirektional (BiDi)<\/strong> bidirektionale Kommunikation ist die zentrale Innovation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u27a4 Warum 100-Gbit\/s-Einzelglasfaser-Module w\u00e4hlen? Wichtige Vorteile:<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Verdoppeln Sie Ihre Faserkapazit\u00e4t:<\/strong> Maximieren Sie die Rendite Ihrer bestehenden <strong>Einmoden-Glasfaser<\/strong> Glasfaserinfrastruktur. Vermeiden Sie kostspielige neue Glasfaserleitungen.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Deutliche Platzersparnis:<\/strong> Verringern Sie die Glasfaserkabeldichte in Racks und Leitungen. Unverzichtbar bei <strong>hochdichten Rechenzentren<\/strong> et <strong>platzbeschr\u00e4nkten Installationen<\/strong>.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Kostenreduktion:<\/strong> Geringere Kosten f\u00fcr Glasfaserkauf, -installation und -verwaltung.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Vereinfachtes Netzwerkdesign und -management:<\/strong> Einfachere Kabelverwaltung und weniger Ausfallstellen.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Zukunftssicherheit:<\/strong> Skalieren Sie die Bandbreite effizient, ohne st\u00e4ndig physische Infrastruktur-Upgrades vornehmen zu m\u00fcssen. Ideal f\u00fcr <strong>Unternehmensnetzwerke<\/strong>, <a href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/5g-fronthaul-high-speed-low-latency-communication-explained\/\" target=\"_blank\" rel=\"\"><strong>5G-Fronthaul<\/strong><\/a>, und<a href=\"https:\/\/resourceslp.szlogic.cn\/de\/fttx-technical-guide-modern-fiber-access-architectures\/\" target=\"_blank\" rel=\"\"> <strong>FTTx-Anwendungen<\/strong><\/a>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u27a4 100-Gbit\/s-Einzelglasfaser vs. herk\u00f6mmlicher Duplex: Ein klarer Vergleich<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Funktion<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>100-Gbit\/s-Einzelglasfaser-(BiDi-)Modul<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Herk\u00f6mmliches 100-Gbit\/s-Duplex-Modul<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u00dcbertragungsart<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Bidirektional (BiDi)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Duplexbetrieb<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Faseranzahl<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>1 Strang<\/strong> (pro Verbindung)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>2 Str\u00e4nge<\/strong> (pro Verbindung)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Technologie<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>WDM (zwei Wellenl\u00e4ngen)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Eine Wellenl\u00e4nge pro Glasfaser<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Faserauslastung<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Hochgradig effizient (2\u00d7)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Standard<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Ideal f\u00fcr<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Glasfaserknappheit, Platzbeschr\u00e4nkungen<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Neubauten, ausreichend Glasfaser vorhanden<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Installationskosten<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Lower<\/strong> (nutzt vorhandene Glasfaser)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her (erfordert mehr Glasfaser)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Kabeldichte<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Verminderte<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u27a4 Erreichen Sie maximale Leistung mit LINK-PP-100-Gbit\/s-Einzelglasfaser-L\u00f6sungen<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/1741a7a104074fadaa8a773eb7fa24b2-1024x608.webp\" alt=\"Unlock Peak Performance with LINK-PP 100G Single Fiber Solutions\" class=\"wp-image-5438\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/1741a7a104074fadaa8a773eb7fa24b2-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/1741a7a104074fadaa8a773eb7fa24b2-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/1741a7a104074fadaa8a773eb7fa24b2-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/1741a7a104074fadaa8a773eb7fa24b2-18x12.webp 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/1741a7a104074fadaa8a773eb7fa24b2.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a>, ein f\u00fchrender Anbieter innovativer optischer Konnektivit\u00e4tsl\u00f6sungen, bietet ein umfassendes Portfolio hochwertiger, zuverl\u00e4ssiger <strong>100-Gbit\/s-Einzelglasfaser-Transceiver<\/strong> f\u00fcr anspruchsvolle Anwendungen konzipiert. Unsere Module halten sich strikt an <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>MSA-Standards<\/strong><\/a> (QSFP28-Formfaktor) und unterst\u00fctzen verschiedene \u00dcbertragungsentfernungen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Hervorgehobene LINK-PP-100G-Einzel-Faser-Transceiver:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>LINK-PP LQ-BL8591100-SRC:<\/strong> Perfekt f\u00fcr <strong>kosteng\u00fcnstige 100G-Verbindungen<\/strong> over <strong>bis zu 100 Meter<\/strong> Milliarden Mal pro Sekunde ein- und ausschaltet. Dieses Muster aus Lichtimpulsen rast durch die Faser \u2013 \u00fcber Tausende von Kilometern \u2013 und wird am anderen Ende wieder in Daten decodiert. <strong>Multimode-Faser <\/strong><a href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\" target=\"_blank\" rel=\"\"><strong>(MMF)<\/strong><\/a>. Ideal f\u00fcr Verbindungen innerhalb eines Rechenzentrums und Unternehmens-Hauptleitungen, die <strong>budgetfreundliche Einzelfaser-L\u00f6sungen ben\u00f6tigen<\/strong>.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>LINK-PP LQ-BLA(B)100-LR1C:<\/strong> Der Arbeitstier f\u00fcr <strong>100G-Einzel-Faser-Anwendungen mit gr\u00f6\u00dferer Reichweite<\/strong>, liefert <strong>bis zu 10 km<\/strong>. Unverzichtbar f\u00fcr <strong>Aggregation im Metro-Netzwerk<\/strong>, <strong>Campus-Verbindungen<\/strong>, und <strong>5G-Midhaul-Deployments, die Einzelfaser-Konnektivit\u00e4t erfordern<\/strong>. (*Wellenl\u00e4ngen: 1271 nm \/ 1331 nm)<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>LINK-PP LQ-BLA(B)100-ER1C:<\/strong> Bew\u00e4ltigen Sie <strong>Herausforderungen bei Einzelfaser-Anwendungen mit erweiterter Reichweite<\/strong> with <strong>bis zu 40 km<\/strong> \u00dcbertragung. Die erste Wahl f\u00fcr <strong>Langstrecken-100G-Einzelstrang-Konnektivit\u00e4t<\/strong> in regionalen Netzen und anspruchsvollen Infrastrukturen. (*Wellenl\u00e4ngen: 1304 nm \/ 1309 nm)<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u27a4 Auswahl des richtigen 100G-Einzel-Faser-Moduls: Wichtige Aspekte<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Erforderliche Entfernung:<\/strong> Passen Sie die Reichweite des Moduls (SR, LR, ER, ZR) an Ihre Verbindungsl\u00e4nge an.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Stellen Sie die Kompatibilit\u00e4t mit Ihrer bestehenden <a href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\" target=\"_blank\" rel=\"\"><strong>Einmodenfasern (SMF)<br><\/strong><\/a>.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Wellenl\u00e4ngenpaarung:<\/strong> Module m\u00fcssen <em>komplement\u00e4re<\/em> komplement\u00e4re Wellenl\u00e4ngen an jedem Ende verwenden (z.\u202fB. 1271 nm\/1331 nm gepaart mit 1331 nm\/1271 nm). <strong>LINK-PP<\/strong> bietet abgestimmte Paare.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Kompatibilit\u00e4t:<\/strong> \u00dcberpr\u00fcfen Sie die Kompatibilit\u00e4t mit Ihrem spezifischen <strong>Switch, Router oder Medienkonverter<\/strong>.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>DDM\/DOM-Unterst\u00fctzung:<\/strong> <strong>Digitale Diagnose\u00fcberwachung<\/strong><a href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/ddm-dom-in-optical-transceivers\/\" target=\"_blank\" rel=\"\"><strong> (DDM)<\/strong><\/a> ist entscheidend f\u00fcr die Echtzeit-Leistungs\u00fcberwachung und Fehlersuche in <strong>Rechenzentrums-Umgebungen<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>ben\u00f6tigen \u2013 LINK-PP bietet streng gepr\u00fcfte L\u00f6sungen, die Leistung und Langlebigkeit garantieren, oft zu einem Bruchteil der OEM-Kosten.<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>100-Gbit\/s-Einzelglasfaser-Transceiver<\/strong> sind keine Nischenl\u00f6sung mehr; sie sind eine strategische Notwendigkeit, um Faserressourcen zu optimieren, Kosten zu senken und skalierbare Hochgeschwindigkeitsnetze zu erm\u00f6glichen. Ob Sie gegen <strong>Faserersch\u00f6pfung<\/strong>, k\u00e4mpfen, ein <strong>hochdichtes Rechenzentrum<\/strong>, planen oder <strong>5G-Transport<\/strong>, <strong>Einzelfaser-Technologie<\/strong> bietet eine leistungsstarke, effiziente L\u00f6sung.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bereit, die Leistungsf\u00e4higkeit der Einzelfaser f\u00fcr Ihre 100G-Anforderungen zu nutzen?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> \u27a1\ufe0f <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/support.htm\"><strong>Kontaktieren Sie unsere optischen Experten f\u00fcr eine individuelle Empfehlung!<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Upgrade intelligenter \u2013 nicht aufw\u00e4ndiger. Entscheiden Sie sich f\u00fcr LINK-PP und profitieren Sie vom Einzelfaser-Vorteil.<\/strong> \u2728<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u27a4 FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Was ist ein 100G-Einzel-Faser-QSFP28-Modul?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ein 100-Gbit\/s-Ein-Faser-QSFP28-Modul \u00fcbertr\u00e4gt 100-Gigabit-Ethernet-Daten \u00fcber eine optische Faser. Dieses Ger\u00e4t erm\u00f6glicht schnellere Netzwerke, ohne dass zus\u00e4tzliche Glasfaserkabel erforderlich sind.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Welche Vorteile bieten 100-Gbit\/s-Ein-Faser-L\u00f6sungen f\u00fcr Netzwerke?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Diese L\u00f6sungen sparen Platz und senken die Kosten. Sie erm\u00f6glichen es Netzwerken, bestehende Glasfaserleitungen f\u00fcr h\u00f6here \u00dcbertragungsraten zu nutzen. Betreiber k\u00f6nnen problemlos weitere Ger\u00e4te hinzuf\u00fcgen und Netzwerke erweitern.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Welche Arten von Netzwerken nutzen 100-Gbit\/s-Ein-Faser-Technologie?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Rechenzentren, Unternehmens-Backbones und Metronetze nutzen diese Technologie. Diese Netzwerke ben\u00f6tigen schnelle Verbindungen und einen zuverl\u00e4ssigen Betrieb rund um die Uhr.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Warum sind QSFP28-Module f\u00fcr moderne Netzwerke wichtig?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP28-Module bieten hohe Portdichte und geringeren Stromverbrauch. Sie passen in g\u00e4ngige Netzwerkger\u00e4te und unterst\u00fctzen das Wachstum von Netzwerken. Diese Module erm\u00f6glichen schnelle Upgrades auch in stark ausgelasteten Umgebungen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Was sollten Betreiber pr\u00fcfen, bevor sie 100-Gbit\/s-Ein-Faser-Module in ihre Netzwerke integrieren?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Betreiber sollten pr\u00fcfen, ob das Ger\u00e4t und der Fasertyp kompatibel sind. Sie m\u00fcssen sicherstellen, dass die Module mit der vorhandenen Netzwerkausr\u00fcstung zusammenarbeiten. Dadurch vermeiden Netzwerke Verbindungsprobleme.<\/p>","protected":false},"excerpt":{"rendered":"<p>100G-Einzel-Faser-QSFP28-Module erm\u00f6glichen schnelle, kosteneffiziente Netzwerk-Upgrades unter Verwendung eines einzigen Faserstrangs \u2013 ideal f\u00fcr skalierbare moderne Rechenzentren.<\/p>","protected":false},"author":1,"featured_media":5437,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5439","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=5439"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5439\/revisions"}],"predecessor-version":[{"id":11254,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5439\/revisions\/11254"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/5437"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=5439"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=5439"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=5439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}