{"id":5436,"date":"2025-08-15T00:00:00","date_gmt":"2025-08-15T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/"},"modified":"2026-06-22T08:25:49","modified_gmt":"2026-06-22T08:25:49","slug":"psm4-vs-cwdm4-which-optical-transceiver-for-your-network","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network","title":{"rendered":"PSM4 vs. CWDM4: Welcher optische Transceiver ist der richtige f\u00fcr Ihr Netzwerk?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp\" alt=\"100G PSM4 VS CWDM4\" class=\"wp-image-5432\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/c590557b74394246abab9a05766937b9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Die Nachfrage nach 100G-Konnektivit\u00e4t in Rechenzentren und Unternehmensnetzwerken steigt rasant. Die Auswahl des richtigen<br> <strong>Optischer Transceiver<\/strong> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>(100G QSFP28)<br><\/strong><\/a> ist entscheidend f\u00fcr Leistung, Kosten, Skalierbarkeit und Energieeffizienz. Zwei dominante<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>MSA<\/strong><\/a> (Multi-Source Agreement)-Standards haben sich durchgesetzt:<br> <strong>PSM4 (Parallel Single Mode fiber, 4-Lane)<br><\/strong> et <strong>CWDM4 (Coarse Wavelength Division Multiplexing, 4-Lane)<br><\/strong>. Obwohl beide 100G \u00fcber 2 km mittels Single-Mode-Faser erreichen,<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>, unterscheiden sich ihre zugrundeliegenden Technologien und idealen Einsatzgebiete erheblich. Das Verst\u00e4ndnis dieser Unterschiede bei 100G-Transceivern ist entscheidend, um Rechenzentrumsnetzwerke zu optimieren und die Kosten f\u00fcr optische Interconnects zu senken.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udd27 PSM4: Parallelit\u00e4t als Leistungsquelle<br><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"618\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp\" alt=\"100G PSM4\" class=\"wp-image-5433\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-300x155.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-1024x527.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-768x396.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d5d0ec3e0f5746b0baf77854ce154dda-18x9.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 (IEEE 802.3bm) verfolgt einen direkten parallelen Ansatz:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Verwendet 4 unabh\u00e4ngige optische Lanes (jede mit<br> <em>1310nm Wellenl\u00e4nge<\/em>).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Faser:<\/strong> Erfordert <strong>8 Fasern<\/strong> (4 Tx, 4 Rx) \u2013 typischerweise in einem MPO-12-Stecker.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funktionsweise:<br><\/strong> Jede Lane \u00fcbertr\u00e4gt gleichzeitig 25 Gbps Daten \u00fcber ihr eigenes dediziertes Faserpaar.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>St\u00e4rken:<\/strong> Einfachere optische Konstruktion mit potenziell niedrigeren Komponentenkosten und hervorragender Signalisolierung.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Schw\u00e4chen:<br><\/strong> H\u00f6herer Faserverbrauch, gr\u00f6\u00dferes Kabelvolumen.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideal f\u00fcr:<\/strong> Ultra-kurze Reichweite (\u2264 500 m) innerhalb von Racks oder Reihen, Hochdicht-Anwendungen mit direkter Anbindung, bei denen der Faserverbrauch keine prim\u00e4re Einschr\u00e4nkung darstellt. Ein zuverl\u00e4ssiges<br> <strong>PSM4-Optikmodul<br><\/strong> wie der <strong>LINK-PP LQ-M31100-DR4C<br><\/strong> liefert konsistente Leistung f\u00fcr diese anspruchsvollen<br> <strong>Parallel-Optik-Anwendungen<br><\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udf08 CWDM4: Wellenl\u00e4ngen-Magie<br><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp\" alt=\"100G CWDM4\" class=\"wp-image-5434\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/74256b059b3d45df852aeb13cbeb7f4b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 (MSA-Spezifikation) nutzt optische Multiplextechnik zur Fasersparung:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Verwendet 4 verschiedene CWDM-Wellenl\u00e4ngen (~1271 nm, 1291 nm, 1311 nm, 1331 nm), die auf ein<br> <em>einzelner<br><\/em> Faserpaar multiplext werden.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Faser:<\/strong> Erfordert nur<br> <strong>2 Fasern<\/strong> (1 Tx, 1 Rx) \u2013 typischerweise LC-Duplex.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Funktionsweise:<br><\/strong> Ein Multiplexer (Mux) kombiniert die 4 Wellenl\u00e4ngen auf der Sende-Faser; ein Demultiplexer (Demux) trennt sie am Empfangsende.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>St\u00e4rken:<\/strong> Reduziert den Faserverbrauch drastisch (4\u00d7 weniger als bei PSM4), kleinere Kabel, einfachere Kabelf\u00fchrung, Standard-LC-Stecker.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Schw\u00e4chen:<br><\/strong> Erfordert komplexere (und potenziell teurere) Laser sowie Mux-\/Demux-Komponenten.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Ideal f\u00fcr:<\/strong> The <strong>Idealbereich f\u00fcr die meisten 100G-Verbindungen mit 2 km Reichweite<br><\/strong> (z. B. Interconnects innerhalb von Rechenzentren, Campus-Verbindungen). Es ist die bevorzugte L\u00f6sung f\u00fcr<br> <strong>CWDM4-Fasereffizienz <\/strong> et <strong>kosteneffiziente 100G-Konnektivit\u00e4t<\/strong>. Das <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>LQ-CW100-FR4C<\/strong><\/a> ist f\u00fcr maximale Zuverl\u00e4ssigkeit in diesen Wellenl\u00e4ngen-Multiplex-Netzwerken ausgelegt.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83e\udd4a Kopf-an-Kopf: PSM4 vs. CWDM4 \u2013 Die wichtigsten Unterschiede<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Funktion<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>PSM4 (100G-PSM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4 (100G-CWDM4)<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Gewinner f\u00fcr \u2026<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Technologie<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d7 parallele 1310-nm-Kan\u00e4le<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d7 WDM (1271\/1291\/1311\/1331 nm)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Einfachheit (PSM4) \/ Fasereffizienz (CWDM4)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Faseranzahl<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>8 Fasern<\/strong> (MPO-12)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>2 Fasern<\/strong> (LC-Duplex)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Deutliche Einsparungen)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Reach<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Bis zu 500 m (optimal), 2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Bis zu 2 km (standard)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Unentschieden (beide bis 2 km, PSM4 besser \u2264 500 m)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Stecker<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO-12\/APC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC-Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Standard, einfachere Verwaltung)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Laserkomplexit\u00e4t<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Einfacher (4\u00d7 gleiche Wellenl\u00e4nge)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Komplexer (4\u00d7 unterschiedliche Wellenl\u00e4ngen, Multiplexer\/Demultiplexer)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>PSM4<\/strong> (Potenziell geringere Kosten)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Kabelvolumen<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her (dickeres Kabel)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Geringer (d\u00fcnneres Kabel)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Hauptanwendungsfall<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kurzstrecke, hohe Dichte<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Standard 2 km ICI, DCI<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00e4ngt von Entfernung\/Faseranforderungen ab<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Kostenfaktor (Komponenten)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Potenziell geringere Laserkosten<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Potenziell h\u00f6here Laserkosten + Multiplexer\/Demultiplexer<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kontextabh\u00e4ngig<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Kostenfaktor (Infrastruktur)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her (mehr Faser\/Verkabelung)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Lower<\/strong> (Weniger Faser\/Verkabelung)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>CWDM4<\/strong> (Gesamtkosten der Infrastruktur)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83c\udfc6 W\u00e4hlen Sie Ihren Champion: PSM4 oder CWDM4?<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>W\u00e4hlen Sie PSM4, wenn:<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Your links are <strong>sehr kurz (\u2264 500 m)<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>die Glasfasersinfrastruktur reichlich vorhanden und kosteng\u00fcnstig ist<\/strong>, und das Kabelvolumen kein gro\u00dfes Problem darstellt.<\/p><\/li><li><p style=\"margin: 0px;\">Sie potenzielle <strong>Komponentenkosteneinsparungen<\/strong> gegen\u00fcber der Fasereffizienz bevorzugen <em>f\u00fcr spezifische Kurzstrecken-Deployments<\/em>.<\/p><\/li><li><p style=\"margin: 0px;\">Sie <strong>hochdichte parallele Optik<\/strong> innerhalb eines begrenzten Raums.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>W\u00e4hlen Sie CWDM4, wenn (die am h\u00e4ufigsten gew\u00e4hlte Option):<\/strong><\/p><ul><li><p style=\"margin: 0px;\">Your links are <strong>bis zu 2\u202fkm<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Faserschonung kritisch ist<\/strong> (spart erhebliche Kosten und Komplexit\u00e4t).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Einfachere Kabelverwaltung<\/strong> LC-Duplex bevorzugt wird.<\/p><\/li><li><p style=\"margin: 0px;\">Sie eine <strong>standardisierte, weit verbreitet interoperable L\u00f6sung ben\u00f6tigen<\/strong> f\u00fcr Rechenzentrum-Interconnects (DCI) oder Unternehmens-Backbone-Verbindungen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Gesamtkosten der Infrastruktur<\/strong> (Faser + Verkabelung + Management) ein entscheidender Faktor sind.<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udca1 LINK-PP-L\u00f6sungen: F\u00fcr Leistung und Wert optimiert<\/strong><br\/>Ob Ihr 100G-Netzwerkdesign die parallele Effizienz von <strong>PSM4<\/strong> oder die Wellenl\u00e4ngenmultiplex-St\u00e4rke von <strong>CWDM4<\/strong>,<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong> LINK-PP<\/strong><\/a> erfordert \u2013 LINK-PP liefert leistungsstarke, MSA-kompatible L\u00f6sungen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>F\u00fcr anspruchsvolle Kurzstrecken-Parallelit\u00e4t:<\/strong> The <strong>LINK-PP-PSM4-Transceiver<\/strong> bieten robuste Leistung f\u00fcr kostenorientierte 100G-Optik in dichten, kurzdistanz-basierten Anwendungen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>F\u00fcr effiziente 2-km-Interconnects:<\/strong> <strong>LINK-PP<\/strong> LINK-PP-CWDM4-Transceiver <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>100G<\/strong> <strong>CWDM4-Transceivern<\/strong><\/a> bieten zuverl\u00e4ssige, stromsparende Leistung, optimiert f\u00fcr skalierbare Rechenzentrums-L\u00f6sungen und breitbandige Unternehmensnetzwerke.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Beide Module unterziehen sich einer strengen<br> <strong>optischen Transceiver-Pr\u00fcfung<br><\/strong> , um Kompatibilit\u00e4t, geringe<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>der Bitfehlerrate (BER)<\/strong><\/a>, und Langlebigkeit sicherzustellen \u2013 damit Sie Vertrauen in Ihre optische Netzwerkinfrastruktur haben.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Fazit: Optimieren Sie Ihre optische Edge<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Verst\u00e4ndnis des <strong>Unterschiede zwischen PSM4 und CWDM4<br><\/strong> ist grundlegend, um fundierte<br> <strong>100G-Transceiver-Auswahlentscheidungen<br><\/strong>. zu treffen. W\u00e4hrend PSM4 Einfachheit f\u00fcr extrem kurze parallele Strecken bietet,<br>, <strong>hat sich CWDM4 aufgrund seiner \u00fcberlegenen Fasereffizienz, einfacheren Verwaltung und niedrigeren Gesamtkosten f\u00fcr die Infrastruktur zum dominierenden Standard f\u00fcr 100G-Verbindungen \u00fcber 2 km entwickelt.<br>.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bereit, Ihren 100G-Einsatz mit der richtigen optischen L\u00f6sung zu optimieren? \ud83d\udd17<br><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49 Entdecken Sie das gesamte Sortiment hochleistungsf\u00e4higer, zuverl\u00e4ssiger 100G-QSFP28-Module von LINK-PP, darunter unsere branchenf\u00fchrenden CWDM4- und PSM4-Transceiver, die speziell darauf ausgelegt sind, f\u00fcr Ihre kritischen Verbindungen maximalen Wert und maximale Betriebszeit zu liefern.<br>. <\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>Besuchen Sie unsere Produktseite \u279e<br><\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Was ist der Hauptunterschied zwischen PSM4 und CWDM4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 ben\u00f6tigt acht Fasern und verwendet MPO\/MTP-Steckverbinder. Es \u00fcbertr\u00e4gt Daten parallel. CWDM4 ben\u00f6tigt nur zwei Fasern und verwendet LC-Duplex-Steckverbinder. Es \u00fcbertr\u00e4gt Daten mithilfe verschiedener Wellenl\u00e4ngen.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>PSM4 eignet sich gut f\u00fcr kurze Verbindungen. CWDM4 ist besser f\u00fcr l\u00e4ngere Entfernungen geeignet.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >Welcher Transceiver l\u00e4sst sich in bestehenden Netzwerken leichter installieren?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 ist in der Regel einfacher zu installieren. Die meisten Netzwerke verwenden bereits LC-Steckverbinder und Zweifaserkabel.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>PSM4 erfordert m\u00f6glicherweise neue Parallelfasern, falls Sie diese nicht bereits besitzen.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Welche Option ist bei kurzen Entfernungen kosteneffizienter?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 ist bei kurzen Verbindungen oft kosteng\u00fcnstiger, sofern Sie bereits \u00fcber Parallelfasern verf\u00fcgen.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>CWDM4 kann bei neuen oder gr\u00f6\u00dferen Netzwerken Kosten f\u00fcr Kabel einsparen.<\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >K\u00f6nnen sowohl PSM4 als auch CWDM4 zuk\u00fcnftige Netzwerk-Upgrades unterst\u00fctzen?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM4 eignet sich besser f\u00fcr Upgrades. Es ben\u00f6tigt weniger Fasern, sodass das Hinzuf\u00fcgen weiterer Verbindungen einfach ist.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>PSM4 ben\u00f6tigt m\u00f6glicherweise mehr Platz, wenn Ihr Netzwerk w\u00e4chst.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Welchen Transceiver sollte ein Rechenzentrum f\u00fcr lange Verbindungen w\u00e4hlen?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ein Rechenzentrum sollte CWDM4 f\u00fcr Verbindungen bis zu 2 Kilometern w\u00e4hlen.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>PSM4 ist am besten f\u00fcr kurze Verbindungen innerhalb eines Geb\u00e4udes geeignet.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Vergleichen Sie PSM4 und CWDM4, um den richtigen 100G-optischen Transceiver f\u00fcr Ihr Netzwerk basierend auf Reichweite, Verkabelung, Kosten und Upgrade-Anforderungen auszuw\u00e4hlen.<\/p>","protected":false},"author":1,"featured_media":5435,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5436","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5436","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=5436"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5436\/revisions"}],"predecessor-version":[{"id":11253,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5436\/revisions\/11253"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/5435"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=5436"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=5436"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=5436"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}