{"id":5423,"date":"2025-08-16T00:00:00","date_gmt":"2025-08-16T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/100g-single-mode-qsfp28-module-types\/"},"modified":"2026-06-22T08:23:41","modified_gmt":"2026-06-22T08:23:41","slug":"100g-single-mode-qsfp28-module-types","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-single-mode-qsfp28-module-types","title":{"rendered":"Untersuchung der 100G-Einmoden-QSFP28-Transceiver-Typen"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6a277037fdbf465da68d3eb2a9e19044.webp\" alt=\"Comparing 100G Single Mode QSFP28 Module Types and Their Use Cases\" class=\"wp-image-5421\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6a277037fdbf465da68d3eb2a9e19044.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6a277037fdbf465da68d3eb2a9e19044-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6a277037fdbf465da68d3eb2a9e19044-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6a277037fdbf465da68d3eb2a9e19044-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6a277037fdbf465da68d3eb2a9e19044-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\"><em>Schwierigkeiten, Rechenzentren oder Campus-Geb\u00e4ude \u00fcber Kilometer hinweg zu verbinden?<\/em><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> The <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm?ca=1516&amp;cv=8480\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"><strong>100G-QSFP28-Einmoden-Glasfaser-(SMF)-Modul<\/strong><\/span><\/a><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> ist Ihr unverzichtbarer Hochgeschwindigkeits-Champion f\u00fcr lange Distanzen. Dieses kompakte Leistungsaggregat l\u00f6st kritische Konnektivit\u00e4ts-Herausforderungen und erm\u00f6glicht eine robuste 100-Gbit\/s-Daten\u00fcbertragung weit jenseits der Reichweite von Multimode-Optiken. Werfen wir einen Blick darauf, warum es f\u00fcr moderne Netzwerke unverzichtbar ist.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Warum 100G-Einmoden-QSFP28-Module w\u00e4hlen?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Moderne Netzwerkarchitekturen erfordern Geschwindigkeit <em>et<\/em> und Reichweite. W\u00e4hrend Multimode-L\u00f6sungen f\u00fcr kurze Verbindungen ausreichend sind, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>sind Einmoden-Glasfaseroptiken<\/strong><\/a> die unbestrittene Wahl f\u00fcr Entfernungen \u00fcber 100 Meter \u2013 oft bis hin zu <strong>80 km, 40 km, 10 km<\/strong>, or <strong>2km<\/strong>. Hier ist, warum 100G-SMF-QSFP28-Module unverzichtbar sind:<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px;\"><strong>\ud83c\udf1f Erweiterte Reichweite:<\/strong> Bew\u00e4ltigen Sie Entfernungen von <strong>2 Kilometern bis zu 100 Kilometern<\/strong> und dar\u00fcber hinaus \u2013 nahtlose Verbindung von Geb\u00e4uden, Campussen oder Metropolregionen. Ideal f\u00fcr <strong>Rechenzentrum-Verbindungen (DCI)<\/strong> et <strong>Metro-Netzwerke<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\u26a1 Hohe Leistung:<\/strong> Liefern Sie konsistente, zuverl\u00e4ssige <strong>100-Gbit\/s-Bandbreite<\/strong> (4 \u00d7 25-Gbit\/s-Kan\u00e4le) unter Einsatz fortschrittlicher Modulation wie <strong>4WDM<\/strong> or <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong><\/a> f\u00fcr gr\u00f6\u00dfere Reichweiten \u2013 und erf\u00fcllen so die Anforderungen an <strong>Hochleistungsrechnernetzwerk <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-hpc-high-performance-computing\/\"><strong>(HPC)<\/strong><\/a> et <strong>Cloud-Infrastruktur<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\ud83d\udcf6 H\u00f6here Signalintegrit\u00e4t:<\/strong> Der kleinere Kern der SMF minimiert die Modendispersion und gew\u00e4hrleistet klarere Signale \u00fcber gro\u00dfe Entfernungen im Vergleich zu <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>Multimode-Faser (MMF)<\/strong><\/a>. Dies f\u00fchrt zu einer geringeren <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>\u00fcber den gesamten 80\u00a0km-Bereich. Maximieren Sie Ihr<\/strong><\/a>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\ud83d\udca1 Zukunftsorientierung:<\/strong> Die Investition in SMF-Infrastruktur bietet einen klaren Pfad f\u00fcr zuk\u00fcnftige Upgrades auf <strong>200G, 400G<\/strong>, und sogar <strong>800G<\/strong> h\u00f6here Geschwindigkeiten mit derselben Glasfaseranlage.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\ud83d\udd0b Effizienz:<\/strong> Moderne Module bieten eine ausgezeichnete Leistung pro Watt \u2013 entscheidend f\u00fcr dichte Installationen und zur Reduzierung des <strong>Gesamtbetriebskosten (TCO)<\/strong>.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Erkl\u00e4rung der verschiedenen Typen von 100G-Einmoden-QSFP28-Modulen<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Nicht alle 100G-SMF-QSFP28-Module sind identisch. Die wichtigsten Varianten unterscheiden sich nach \u00dcbertragungstechnologie und Zielentfernung:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px 0px 4px;\"><strong>\ud83d\udce1 100GBASE-LR4 \/ 100G-LR4-QSFP28-Transceiver:<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Standard:<\/strong> IEEE 802.3ba<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Wellenl\u00e4ngen:<\/strong> 4 Kan\u00e4le mit <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-lwdm-and-why-important-for-lans\/\"><strong>LWDM<\/strong><\/a> Wellenl\u00e4ngen (ca. 1295 nm, 1300 nm, 1304 nm, 1309 nm).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> <strong>Bis zu 10 km<\/strong> Milliarden Mal pro Sekunde ein- und ausschaltet. Dieses Muster aus Lichtimpulsen rast durch die Faser \u2013 \u00fcber Tausende von Kilometern \u2013 und wird am anderen Ende wieder in Daten decodiert. <strong>OS2-Einmoden-Glasfaser<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Hauptanwendungsfall:<\/strong> Standard-Arbeitspferd f\u00fcr Verbindungen innerhalb eines Campus oder zwischen Rechenzentren bis zu 10 km.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>LINK-PP-Modell: <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\"><strong>LQ-LW100-LR4C<\/strong><\/a><\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>\ud83d\udce1 100GBASE-ER4 \/ 100G-ER4-QSFP28-Modul:<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Standard:<\/strong> IEEE 802.3ba (Extended Reach)<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Wellenl\u00e4ngen:<\/strong> 4 Kan\u00e4le mit <strong>LAN-WDM<\/strong> Wellenl\u00e4ngen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> <strong>Bis zu 40 km<\/strong> auf OS2-SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Hauptanwendungsfall:<\/strong> L\u00e4ngere DCI-Verbindungen (Data Center Interconnect) und Metro-Ringe.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>LINK-PP-Modell: <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472708.htm\"><strong>LQ-LW100-ER4C<\/strong><\/a><\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>\ud83d\udcf6 100G-ZR4-QSFP28 (h\u00e4ufig koh\u00e4rent):<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Standard:<\/strong> Oftmals basierend auf OIF-Implementierungsvereinbarungen oder propriet\u00e4ren L\u00f6sungen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Verwendet typischerweise <strong>koh\u00e4renten Optiken<\/strong> und erweiterte Modulation (z.\u202fB., <strong>DP-QPSK<\/strong>).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> <strong>Bis zu 80km<\/strong> oder sogar <strong>100 km+<\/strong> auf OS2-SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Hauptanwendungsfall:<\/strong> Langstrecken-DCI, Netze von Dienstanbietern. (Hinweis: Verbraucht oft mehr Leistung als LR4\/ER4.).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>LINK-PP-Modell: <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482513.htm\"><strong>LQ-LW100-ZR4C<\/strong><\/a><\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>\ud83d\udcf6 100G DR\/FR\/LR (PAM4-basiert \u2013 z.\u202fB. 100G-FR1\/100G-LR1):<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Standard:<\/strong> IEEE 802.3cu (<strong>100G \u00fcber<\/strong> <strong>Single-Lambda<br><\/strong>)<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Uses <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4-Modulation<\/strong><\/a> um 100 Gbps \u00fcber eine <em>einzelner<br><\/em> Wellenl\u00e4nge\/Laser zu \u00fcbertragen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> <strong>DR (500 m)<\/strong> verwendet typischerweise Multimodefasern (MMF), <strong>FR (2 km)<\/strong> et <strong>LR (10 km)<\/strong> verwenden Single-Mode-Fasern (SMF).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Hauptanwendungsfall:<\/strong> Bietet eine einfachere und potenziell kosteng\u00fcnstigere L\u00f6sung f\u00fcr bestimmte Reichweitenpunkte (2 km, 10 km) unter Verwendung nur einer oder zweier Fasern (BiDi-Varianten verf\u00fcgbar).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>LINK-PP-Modell: <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482616.htm\"><strong>LQ-SM31100-DR1C<\/strong><\/a><\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Wichtige Spezifikationen und Leistungskennwerte<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Funktion<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Typischer Wert\/Bereich<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Wichtigkeit<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Datenrate<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100 Gbps (4\u00d725G NRZ oder 1\u00d7\/2\u00d7 PAM4)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kernfunktion \u2013 Hochgeschwindigkeits-Konnektivit\u00e4t.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Reach<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2 km, 10 km, 40 km, 80 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Definiert den Anwendungsbereich (DCI, Metro, Campus).<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Fasertyp<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>OS2 Single-Mode-Faser<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Unverzichtbar, um die angegebenen Entfernungen zu erreichen.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Wellenl\u00e4nge<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>CWDM, LAN-WDM, spezifische Lambda (PAM4)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kompatibilit\u00e4t mit Optiken und Filtern.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Stecker<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>0\u00b0C bis +70\u00b0C<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Standard-Schnittstelle f\u00fcr SMF-Patchpanels.<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Stromverbrauch<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~3,5 W \u2013 6 W+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Beeinflusst Dichte, K\u00fchlung und Betriebskosten (TCO).<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>DDM\/DOM<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Yes<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/ddm-dom-in-optical-transceivers\/\"><strong>Digitale Diagnose\u00fcberwachung<\/strong><\/a> entscheidend f\u00fcr proaktive Wartung.<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 Warum LINK-PP f\u00fcr Ihre 100G Single-Mode QSFP28-Anforderungen w\u00e4hlen?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0086ff9cf16c4136afdc46bfa6ac70f6.webp\" alt=\"100g qsfp28 transceivers\" class=\"wp-image-5422\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0086ff9cf16c4136afdc46bfa6ac70f6.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0086ff9cf16c4136afdc46bfa6ac70f6-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0086ff9cf16c4136afdc46bfa6ac70f6-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0086ff9cf16c4136afdc46bfa6ac70f6-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0086ff9cf16c4136afdc46bfa6ac70f6-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bei der Bereitstellung missionkritischer <strong>100G optics<\/strong>, sind Zuverl\u00e4ssigkeit, Leistung und Kompatibilit\u00e4t unverzichtbar. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a> bietet Premium- <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>100G-QSFP28-Transceiver<\/strong><\/a> entwickelt f\u00fcr Exzellenz:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>\u2705 Strenge Kompatibilit\u00e4tstests:<\/strong> Garantierte Interoperabilit\u00e4t mit g\u00e4ngigen OEM-Switches und -Routern (Cisco, Juniper, Arista, NVIDIA usw.), um kostspielige <strong>Netzwerkkompatibilit\u00e4tsprobleme zu vermeiden<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\u2705 Unkompromittierte Qualit\u00e4t:<\/strong> Herstellung nach h\u00f6chsten Standards, um niedrige <strong>\u00fcber den gesamten 80\u00a0km-Bereich. Maximieren Sie Ihr<\/strong> und langfristige Stabilit\u00e4t f\u00fcr Ihr <strong>Hochgeschwindigkeits-Netzwerkinfrastrukturen<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\u2705 Vollst\u00e4ndige DDM\/DOM-Unterst\u00fctzung:<\/strong> Echtzeit\u00fcberwachung von Temperatur, Spannung sowie Sende-\/Empfangsleistung f\u00fcr <strong>proaktives Netzwerkmanagement<\/strong> und vereinfachte Fehlerbehebung.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>\u2705 Kosteneffiziente L\u00f6sung:<\/strong> Unternehmensf\u00e4hige Leistung ohne den Aufpreis markengebundener Optiken \u2013 senkt Ihre <strong>Kosten f\u00fcr optische Netzwerke deutlich<\/strong>.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Entdecken Sie unsere leistungsstarken LINK-PP 100G Single-Mode QSFP28-Module:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\"><strong>LQ-LW100-LR4C<\/strong><\/a><strong>:<\/strong> Ideale Standardl\u00f6sung f\u00fcr eine Reichweite von 10 km. Perfekt f\u00fcr <strong>Speicherarrays<\/strong> und Campus-Backbones.<\/p><\/li><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472708.htm\"><strong>LQ-LW100-ER4C<\/strong><\/a><strong>:<\/strong> Bew\u00e4ltigen Sie gr\u00f6\u00dfere Entfernungen bis zu 40 km f\u00fcr <strong>Metro-Ethernet-Anwendungen<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482513.htm\"><strong>LQ-LW100-ZR4C<\/strong><\/a><strong>:<\/strong> Meistern Sie anspruchsvolle Langstrecken-DCI-Verbindungen ab 80 km <strong>(koh\u00e4rente Technologie).<\/strong> (coherent technology).<\/p><\/li><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482616.htm\"><strong>LQ-SM31100-DR1C:<\/strong><\/a> Effiziente, auf PAM4 basierende 2 km\/10 km-Optionen zur Vereinfachung der Glasfaser-Nutzung.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\ude80 Bereit, Ihr Netzwerk mit zuverl\u00e4ssigen 100G-L\u00f6sungen zukunftssicher zu machen?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lassen Sie sich nicht durch die Entfernung bei Ihrer Bandbreite einschr\u00e4nken. <strong>LINK-PP<\/strong>\u2018Die hochwertigen, kompatiblen 100G Single-Mode-QSFP28-Module von <strong> bieten die robuste, weitreichende Konnektivit\u00e4t, die Ihr sich weiterentwickelndes Netzwerk ben\u00f6tigt. Gew\u00e4hrleisten Sie nahtlose Skalierbarkeit und Spitzenleistung.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udc49 Durchsuchen Sie noch heute unser gesamtes Sortiment an 100G-QSFP28-Modulen und fordern Sie ein Angebot an! <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>Jetzt beschaffen \u279e<br><\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u2705 FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Was ist der Hauptunterschied zwischen LR4- und ER4-Modulen?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">LR4-Module arbeiten bis zu einer Entfernung von 10 Kilometern. ER4-Module erreichen bis zu 40 Kilometer. ER4-Module verbrauchen mehr Leistung und ben\u00f6tigen h\u00e4ufig Unterst\u00fctzung f\u00fcr lange Glasfaserstrecken.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >K\u00f6nnen Ingenieure verschiedene QSFP28-Modultypen in einem Netzwerk mischen?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ingenieure k\u00f6nnen verschiedene Modultypen gemeinsam verwenden, sofern die Module denselben Standards entsprechen. Pr\u00fcfen Sie vor der Inbetriebnahme stets, ob Ger\u00e4te und Glasfaser zueinander kompatibel sind.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Warum verwenden einige Module MPO-Steckverbinder statt LC-Duplex-Steckverbinder?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">MPO-Steckverbinder erm\u00f6glichen die gleichzeitige Daten\u00fcbertragung \u00fcber mehrere Fasern. Dies ist besonders hilfreich bei vielen Kabeln und hoher Datenrate auf engem Raum, beispielsweise in gro\u00dfen Server-Racks.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Wie verbessert die PAM4-Modulation die Daten\u00fcbertragung?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Die PAM4-Modulation erm\u00f6glicht es, mehr Daten pro Wellenl\u00e4nge zu \u00fcbertragen. Dadurch ergeben sich h\u00f6here Geschwindigkeiten, ohne zus\u00e4tzliche Glasfaserleitungen einzusetzen. Sie eignet sich gut f\u00fcr neue Hochgeschwindigkeitsnetzwerke.<\/p>","protected":false},"excerpt":{"rendered":"<p>Erforschen Sie die verschiedenen 100G-Einmoden-QSFP28-Modultypen nach Reichweite, Kosten und Einsatzgebiet, um den optimalen Transceiver f\u00fcr Rechenzentren, Metro- oder Langstreckennetze auszuw\u00e4hlen.<\/p>","protected":false},"author":1,"featured_media":5421,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5423","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5423","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=5423"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5423\/revisions"}],"predecessor-version":[{"id":11249,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5423\/revisions\/11249"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/5421"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=5423"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=5423"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=5423"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}