{"id":5417,"date":"2025-08-16T00:00:00","date_gmt":"2025-08-16T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide\/"},"modified":"2026-06-22T09:08:37","modified_gmt":"2026-06-22T09:08:37","slug":"100g-qsfp28-optical-transceivers-selection-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide","title":{"rendered":"Ein umfassender Leitfaden zur Auswahl von 100G-QSFP28-Optiktransceivern: SR4, LR4, CWDM4 und mehr"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa.webp\" alt=\"100g qsfp28 transceivers\" class=\"wp-image-5415\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/a117d9c4ef2b4fb1ba276f80e39727aa-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\">Wenn Sie ein<br> <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><span class=\"qc-p1-tag\"><strong>100G-QSFP28-Transceivers<\/strong><\/span><\/a><span class=\"qc-p1-tag\">, ausw\u00e4hlen, sollten Sie \u00fcberlegen, was Ihr Netzwerk ben\u00f6tigt. Pr\u00fcfen Sie wichtige Aspekte wie Kompatibilit\u00e4t, die erforderliche Daten\u00fcbertragungsstrecke, Fasertyp, Steckertyp, Einsatzort sowie zuk\u00fcnftige Einsatzm\u00f6glichkeiten. Die Auswahl von QSFP28-Optiktransceivern, die zu Ihrem System passen, sorgt f\u00fcr einen reibungslosen Netzwerkbetrieb und sch\u00fctzt Ihre Investition.<br>. <\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">Dieser umfassende Leitfaden beseitigt die Verwirrung und beleuchtet alle wesentlichen 100G-QSFP28-Optionen \u2013 von<br> <\/span><span class=\"qc-p1-tag\"><strong>SR4<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> et <\/span><span class=\"qc-p1-tag\"><strong>LR4<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> to <\/span><span class=\"qc-p1-tag\"><strong>CWDM4<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">, <\/span><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-single-lambda-transceivers-benefits-upgrades-performance\/\"><span class=\"qc-p1-tag\"><strong>Single-Lambda<br><\/strong><\/span><\/a><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">, und dar\u00fcber hinaus \u2013, um Ihnen eine fundierte Entscheidung f\u00fcr Ihr<br> <\/span><span class=\"qc-p1-tag\"><strong>Hochgeschwindigkeits-Konnektivit\u00e4t<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> .<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Was ist ein QSFP28-Optikmodul?<br><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">The <strong>QSFP28 (Quad Small Form-factor Pluggable 28)<\/strong> ist das branchen\u00fcbliche Formfaktor-Standardformat f\u00fcr 100-Gigabit-Ethernet (100GbE) und Hochgeschwindigkeits-Data-Center-Verbindungen. Es fasst vier \u00dcbertragungslanes mit je 25 Gbit\/s oder eine einzelne Hochgeschwindigkeitslane in einem kompakten, hot-pluggablen Modul zusammen.<br>.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Entmystifizierung Ihrer 100G-QSFP28-Optionen: Eine technische \u00dcbersicht<br><\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p style=\"margin: 0px 0px 4px;\"><strong>100G-SR4 (Kurzstrecke)<br><\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Parallele Multimode-Faser (MMF) mit 4 Lanes (4\u00d725G NRZ).<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> Bis zu 70 m (OM3-MMF), 100 m (OM4-MMF) oder 150 m (OM5-MMF).<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Erfordert <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/mpo-connectors-differences-8-12-16-24-fiber-comparison\/\"><strong>MTP\/MPO-12<\/strong><\/a> Stecker. Verwendet 4 Fasern f\u00fcr Tx und 4 Fasern f\u00fcr Rx<br> <strong>(insgesamt 8 Fasern)<br><\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Am besten geeignet f\u00fcr:<\/strong> <strong>Top-of-Rack-Switching<br><\/strong>, <strong>intra-Rechenzentrums-Verbindungen<\/strong>, Server-zu-Leaf-Verbindungen innerhalb von Racks oder Reihen unter Verwendung von<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>Multimode-Faserkabeln<br><\/strong><\/a>. Kosteng\u00fcnstig f\u00fcr kurze Distanzen.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Modellbeispiel:<br><\/strong> QSFP28-100G-SR4 <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473115.htm\"><strong>LQ-M85100-SR4C<\/strong><\/a> (unterst\u00fctzt OM3\/OM4\/OM5)<br><\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-PSM4 (Parallel Single Mode, 4 Lanes)<br><\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Parallele Einmodenfaser<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a> mit 4 Lanes (4\u00d725G NRZ).<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> Typischerweise bis zu 500 m \u00fcber Standard-SMF.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Erfordert <strong>MTP\/MPO-12<\/strong> Stecker. Verwendet 4 Fasern f\u00fcr Tx und 4 Fasern f\u00fcr Rx<br> <strong>(insgesamt 8 Fasern)<br><\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Am besten geeignet f\u00fcr:<\/strong> L\u00e4ngere interne Data-Center- oder Campus-Verbindungen als SR4 erm\u00f6glicht, wo bereits SMF-Infrastruktur vorhanden ist oder aus Zukunftsorientierung bevorzugt wird. Weniger verbreitet als CWDM4\/LR4 f\u00fcr l\u00e4ngere SMF-Strecken.<br>.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-LR4 \/ ER4 \/ ZR4 (Langstrecke \/ Erweiterte Reichweite \/ Erweiterte+ Reichweite)<br><\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Wellenl\u00e4ngenmultiplexverfahren mit groben Kanalabst\u00e4nden (Coarse Wavelength Division Multiplexing) <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-cwdm-understanding-coarse-wavelength-division-multiplexing\/\"><strong>(CWDM)<\/strong><\/a> \u00fcber Duplex-SMF. Kombiniert 4 Wellenl\u00e4ngen (ca. 1295, 1300, 1304, 1309 nm) auf 2 Fasern (1 Tx, 1 Rx). LR4 ist der Standard, ER4 bietet erweiterte Reichweite, ZR4 die gr\u00f6\u00dfte Reichweite.<br>.<\/p><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>Reichweite:<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>LR4:<\/strong> Bis zu 10 km<\/p><\/li><li><p style=\"margin: 0px;\"><strong>ER4:<\/strong> Bis zu 40 km<\/p><\/li><li><p style=\"margin: 0px;\"><strong>ZR4:<br><\/strong> Bis zu 80 km+<br><\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Verwendet Standard-<br> <strong>Duplex-LC-<\/strong> Stecker. Erfordert nur 2 Fasern.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Am besten geeignet f\u00fcr:<\/strong> <strong>Data-Center-Interconnect (DCI)<\/strong>, <strong>Metro-Netzwerken<\/strong>, Geb\u00e4ude-zu-Geb\u00e4ude-Verbindungen, Aggregationsschichten. Unverzichtbar f\u00fcr<br> <strong>Langstrecken-\u00dcbertragung \u00fcber Lichtwellenleiter<\/strong>. ER4\/ZR4 sind f\u00fcr spezialisierte Langstreckenanwendungen vorgesehen.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Modellbeispiel:<br><\/strong> LINK-PP QSFP28-100G-LR4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\"><strong>LQ-LW100-LR4C<\/strong><\/a> (10 km), LINK-PP QSFP28-100G-ER4<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472708.htm\"><strong>LQ-LW100-ER4C<\/strong><\/a> (40 km), LINK-PP QSFP28-100G-ZR4<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482513.htm\"><strong>LQ-LW100-ZR4C<\/strong><\/a> (80 km)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-CWDM4<br><\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> \u00c4hnlich wie LR4, verwendet <strong>CWDM<\/strong> \u00fcber Duplex-SMF, jedoch mit leicht unterschiedlichen Wellenl\u00e4ngen (1271, 1291, 1311, 1331 nm), optimiert f\u00fcr geringere Kosten und geringeren Stromverbrauch.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> Bis zu 2 km. Definiert durch die CWDM4-MSA.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Verwendet Standard-<br> <strong>Duplex-LC-<\/strong> Stecker. Erfordert nur 2 Fasern.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Am besten geeignet f\u00fcr:<\/strong> Kosteng\u00fcnstige L\u00f6sung f\u00fcr <strong>Intra-Data-Center-SMF-Verbindungen<\/strong> bis zu 2 km (z.\u202fB. zwischen Geb\u00e4uden auf einem Campus, \u00fcber gr\u00f6\u00dfere Data-Halls hinweg). Eine beliebte Alternative zu PSM4 f\u00fcr Duplex-SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Modellbeispiel:<br><\/strong> LINK-PP QSFP-100G-CWDM4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>LQ-CW100-FR4C<\/strong><\/a> (2 km)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G Single Lambda (z.\u202fB. FR1\/LR1\/ER1\/DR1\/ZR1)<\/strong><\/p><ul><li><p style=\"margin: 0px 0px 4px;\"><strong>Technologie:<\/strong> Verwendet einen <em>einzelner<br><\/em> Hochgeschwindigkeitswellenl\u00e4nge (z.\u202fB. 53,125 Gbaud <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4-Modulation<\/strong><\/a>) \u00fcber Duplex-SMF. Umfasst verschiedene Reichweiten:<\/p><ul><li><p style=\"margin: 0px;\"><strong>FR1 (2 km) \/ LR1 (10 km):<\/strong> G\u00e4ngige Standards.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>DR1 (500 m):<\/strong> Verwendet h\u00e4ufig die Wellenl\u00e4nge 1310 nm.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>ER1 (40 km) \/ ZR1 (80 km+):<\/strong> Varianten mit gr\u00f6\u00dferer Reichweite.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> Unterschiedlich (500 m, 2 km, 10 km, 40 km, 80 km+).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Verwendet Standard-<br> <strong>Duplex-LC-<\/strong> Stecker. Erfordert nur 2 Fasern.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Am besten geeignet f\u00fcr:<\/strong> <strong>Zuk\u00fcnftige Data-Center-Architekturen<\/strong>, Vereinfachung der Glasfaserinfrastruktur (nur 2 Fasern pro Verbindung erforderlich), Vorbereitung auf 400G\/800G (die stark auf PAM4 setzen). Bietet <strong>h\u00f6here Anschlusssdichte<\/strong> Potenzial. Schl\u00fcssel f\u00fcr <strong>zukunftssicheres Netzwerkdesign<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Modellbeispiel:<br><\/strong> LINK-PP QSFP-100G-DR1 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482616.htm\"><strong>LQ-SM31100-DR1C<\/strong><\/a> (10 km).<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G-SWDM4 (Short Wavelength Division Multiplexing)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Nutzt Wellenl\u00e4ngenmultiplexverfahren \u00fcber MMF. Kombiniert 4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/overview-of-vcsel\/\"><strong>VCSEL<\/strong><\/a>-basierte Wellenl\u00e4ngen (850, 880, 910, 940 nm) auf 2 Fasern (1 Tx, 1 Rx).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> Bis zu 75 m (OM3), 100 m (OM4), 150 m (OM5).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Verwendet Standard-<br> <strong>Duplex-LC-<\/strong> Stecker. Erfordert nur 2 Fasern.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Am besten geeignet f\u00fcr:<\/strong> Nutzung bestehender <strong>LC-Duplex-MMF-Verkabelung<\/strong> f\u00fcr 100G, wodurch MTP\/MPO-Upgrades entfallen. Ideal f\u00fcr <strong>Faser-Migrationsstrategien<\/strong> bei vorherrschender Duplex-MMF-Infrastruktur.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Modellbeispiel:<br><\/strong> LINK-PP QSFP-100G-SWDM4 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473140.htm\"><strong>LQ-SW100-SR4C<\/strong><\/a> (100 m)<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G Bidirektional (BiDi)<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Verwendet einen <em>einzelner<br><\/em> einzelner Faserstrang. Erreicht vollduplexf\u00e4hige 100G-Daten\u00fcbertragung durch Senden und Empfangen auf zwei unterschiedlichen Wellenl\u00e4ngen (z.\u202fB. Tx 1330 nm \/ Rx 1270 nm) \u00fcber dieselbe Faser.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> Typischerweise bis zu 10 km oder 20 km \u00fcber SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Verwendet einen <strong>einzelner simplex LC-<\/strong> Stecker. Erfordert nur 1 Faserstrang pro Verbindung.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Am besten geeignet f\u00fcr:<\/strong> <strong>Maximierung bestehender Glasfaserinfrastruktur<\/strong> (Verdopplung der Kapazit\u00e4t), <strong>Szenarien mit ersch\u00f6pfter Faserkapazit\u00e4t<\/strong>, kosteneffiziente Upgrades bei knapper Faserinfrastruktur. Unverzichtbar f\u00fcr <strong>Optimierung der Faserkapazit\u00e4t<\/strong>.<\/p><\/li><\/ul><\/li><li><p style=\"margin: 0px 0px 4px;\"><strong>100G\/112G Dual-Rate-Module<\/strong><\/p><ul><li><p style=\"margin: 0px;\"><strong>Technologie:<\/strong> Hermetische TOSA mit <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-lwdm-and-why-important-for-lans\/\"><strong>LAN-WDM<\/strong><\/a> -basierter DFB-Laserdiode mit Datenraten von 25,78 G\/s und 27,95 G\/s.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Reichweite:<\/strong> Typischerweise bis zu 10 km \u00fcber SMF<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Fasertyp:<\/strong> Verwendet Standard-<br> <strong>Duplex-LC-<\/strong> Stecker. Erfordert nur 2 Fasern.<br>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Am besten geeignet f\u00fcr:<\/strong> 100GBASE-LR4-Ethernet-Verbindungen, InfiniBand QDR- und DDR-Interconnects, kundenseitige 100G-Telecom-Verbindungen.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Modellbeispiel:<br><\/strong> LINK-PP <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488452.htm\"><strong>LQ-LW112-LR4C<\/strong><\/a>.<\/p><\/li><\/ul><\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005.webp\" alt=\"100g qsfp28 module\" class=\"wp-image-5416\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5d7fcaaefde14dedb89f4bc7ecd50005-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>100G-QSFP28-Transceiver im Vergleich auf einen Blick<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Modultyp<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Technologie<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Wellenl\u00e4nge<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Fasertyp &amp; Stecker<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Max Reichweite<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Schl\u00fcsselanwendung<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-SR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725 G NRZ (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>850nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MMF \/ MPO-12<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>70 m\u2013150 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kurze Intra-DC-, ToR-Switching-Anwendungen<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-PSM4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725 G NRZ (SMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ MPO-12<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>500m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mittelstrecke Intra-DC\/Campus (parallel)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-LR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725 G LWDM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>ca. 1295\u20131310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC-Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>DCI, Metro-, Geb\u00e4udeverbindungen<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-ER4\/ZR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725 G LWDM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>ca. 1295\u20131310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC-Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>40 km \/ 80 km+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Langstrecken-DCI, Metro<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-CWDM4<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725 G CWDM<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1271\u20131331 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC-Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>2km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kostenoptimierte Intra-DC-SMF-L\u00f6sung<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-Einzelwellenl\u00e4nge<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1\u00d7100 G PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1310 nm (z. B.)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ LC-Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>500 m\u201380 km+<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Next-Gen-DC, vereinfachte Glasfaserinfrastruktur<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G-SWDM4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4\u00d725 G WDM (MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>850\u2013940 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MMF \/ LC-Duplex<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>75 m\u2013150 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Nutzung vorhandener Duplex-MMF-Verkabelung<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100G BiDi<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>1\u00d7100 G BiDi<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>z. B. Tx1330\/Rx1270<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ Simplex-LC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10 km \/ 20 km \/ 40 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Faserauslastung, Einzelfaser<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Dual-Rate (z. B. LR4)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100 G \/ 112 G <\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LAN-WDM, 1295\u20131309 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SMF \/ Duplex-LC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Abh\u00e4ngig vom Betriebsmodus<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Migration, Aggregationsflexibilit\u00e4t<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Auswahl des richtigen LINK-PP-QSFP28-Moduls: Wichtige Kriterien<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Erforderliche Entfernung:<\/strong> Dies ist der prim\u00e4re Entscheidungsfaktor (SR4 f\u00fcr &lt;150 m MMF, CWDM4 f\u00fcr 2 km SMF, LR4 f\u00fcr 10 km usw.).<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Glasfaserinfrastruktur:<\/strong> Was bereits installiert ist (MMF vs. SMF, MPO vs. LC-Duplex\/Simplex)? SWDM4 nutzt Duplex-MMF, BiDi nutzt Simplex-SMF.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Kosten:<\/strong> SR4 und CWDM4 sind im Allgemeinen kosteng\u00fcnstiger als LR4\/ER4 oder Single-Lambda-L\u00f6sungen. BiDi kann die Glasfaskosten senken.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Stromverbrauch:<\/strong> CWDM4 und neuere PAM4-Module <strong>(Single-Lambda)<\/strong> haben oft eine geringere Leistungsaufnahme als LR4.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Zukunftssicherheit:<\/strong> Single-Lambda-Module sind kompatibel mit 400G-\/800G-Technologien, die <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>PAM4<\/strong><\/a>.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Doppelratenanforderungen:<\/strong> Ben\u00f6tigen Sie jetzt oder in Zukunft eine 4\u00d725-Gbit\/s- oder 4\u00d728-Gbit\/s-Konnektivit\u00e4t?<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Glasfaserkapazit\u00e4t:<\/strong> Ist die Glasfaser knapp? BiDi-Module verdoppeln effektiv Ihre Glasfaserkapazit\u00e4t.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Optimieren Sie Ihr 100G-Netzwerk mit Zuversicht<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Auswahl des optimalen <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\"><strong>100G-QSFP28-Transceivers<\/strong><\/a> ist grundlegend f\u00fcr die Erreichung von <strong>Hochleistungs-Netzwerken<\/strong>, <strong>einer skalierbaren Rechenzentrumsarchitektur<\/strong>, und <strong>einer Maximierung der Rendite<\/strong> auf Ihre <strong>Glasfasernetzwerkinfrastruktur<\/strong>. Indem Sie die St\u00e4rken jeder Technologie verstehen \u2013 von den kosteneffizienten <strong>100G-SR4<\/strong> f\u00fcr Racks bis hin zu den Langstreckenf\u00e4higkeiten von <strong>100G-LR4\/ER4<br><\/strong>, der fasersparenden Magie von <strong>100G-BiDi<\/strong>, oder den zukunftssicheren <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-single-lambda-transceivers-benefits-upgrades-performance\/\"><strong>100G-Single-Lambda-(PAM4)-Modulen<\/strong><\/a> \u2013 k\u00f6nnen Sie strategische Entscheidungen treffen, die Ihren spezifischen <strong>Netzwerkdesign-Anforderungen entsprechen<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bereit f\u00fcr den Einsatz hochleistungsf\u00e4higer 100G-Konnektivit\u00e4t?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>LINK-PP bietet ein umfassendes Portfolio zuverl\u00e4ssiger, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/multi-source-agreements-optical-transceivers\/\"><strong>MSA-konform<\/strong><\/a><strong> 100G-QSFP28-Optikmodule<\/strong>, einschlie\u00dflich aller hier besprochenen Typen: <strong>SR4<\/strong>, <strong>LR4<\/strong>, <strong>ER4<\/strong>, <strong>CWDM4<\/strong>, <strong>Single-Lambda-(DR1\/FR1)-<\/strong>, <strong>SWDM4<\/strong>, <strong>BiDi<\/strong>, und <strong>Dual-Rate-Betrieb<\/strong> L\u00f6sungen. Unsere Transceiver werden streng auf <strong>Interoperabilit\u00e4t<\/strong> Kompatibilit\u00e4t und Leistung getestet, um eine nahtlose Integration in Ihre <strong>Cisco<\/strong>, <strong>Arista,<\/strong>, <strong>Juniper<\/strong>, <strong>Mellanox-<\/strong>, or <strong>Huawei<\/strong> Switches und Router sicherzustellen.<\/p>\n\n\n\n<div class=\"alignnone qc-cover-wrapper has-custom-content-position is-position-center\" elementtype=\"div\" useimagebackground=\"false\" imgbg=\"\" imgbgpositionleft=\"50\" imgbgpositiontop=\"50\" overlay=\"#165DFF\" overlayopacity=\"0.8\" contentposition=\"center\" alt=\"\" parallax=\"false\" style=\"border-radius: 12px; padding-left: var(--qc-preset--spacing--60); padding-right: var(--qc-preset--spacing--60); padding-top: var(--qc-preset--spacing--50); padding-bottom: var(--qc-preset--spacing--50); background-color: rgb(245, 245, 245); height: auto;\"><div class=\"qc-cover-wrapper__inner-container\"><div style=\"flex-wrap: wrap; justify-content: center; display: flex;\"><div colmd=\"10\" class=\"col col-md-10\"><p style=\"text-align: center;\"><span class=\"qc-h1-tag\" style=\"color: var(--qc-color5);\">LINK-PP Solutions<\/span><\/p><p style=\"text-align: center;\"><strong>Entdecken Sie noch heute das vollst\u00e4ndige Spektrum an 100G-QSFP28-Modulen!<\/strong><\/p><div class=\"qc-buttons-wrapper\"><div justification=\"center\" class=\"qc-buttons-container is-horizontal is-content-justification-center\" style=\"margin-top: var(--qc-preset--spacing--0); margin-bottom: var(--qc-preset--spacing--0); gap: var(--qc-preset--spacing--40);\"><div link=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\" opennewtab=\"true\" width=\"\" outline=\"false\" class=\"qc-button-wrapper\" style=\"background-color: var(--qc-color1);\"><a class=\"qc-button-container\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\" target=\"_blank\"><span style=\"color: rgb(191, 61, 55);\"><strong>\ud83d\udd0dJetzt Quelle finden<\/strong><\/span><\/a><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\ud83d\udcdd Siehe auch<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-optical-transceiver-form-factors-guide\/\">Formfaktoren f\u00fcr 100G-Optiktransceivermodule: CFP, CFP2, CFP4, CXP, QSFP28<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-single-lambda-transceivers-benefits-upgrades-performance\/\">Was Sie \u00fcber 100G-Single-Lambda-Optik wissen m\u00fcssen<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-single-lambda-vs-4-channel-optical-modules-comparison\/\">Vergleich von 100G-Einzel-Lambda- und 4-Kanal-optischen Modulen: Wichtige Unterschiede<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/\">PSM4 vs. CWDM4-Transceiver: Wichtige Unterschiede erkl\u00e4rt<\/a><\/p>\n\n\n\n<script>const link1 = document.createElement('link');link1.rel = 'stylesheet';link1.type = 'text\/css';link1.href = 'https:\/\/statics.quickcreator.io\/static\/theme\/css\/qcb-theme-additional.css';const link2 = document.createElement('link');link2.rel = 'stylesheet';link2.type = 'text\/css';link2.href = 'https:\/\/statics.quickcreator.io\/static\/aaapycm22qmuab44\/theme\/css\/qcb-main-theme.css';document.head.appendChild(link1);document.head.appendChild(link2);<\/script>","protected":false},"excerpt":{"rendered":"<p>W\u00e4hlen Sie den besten 100G-QSFP28-Optiktransceiver f\u00fcr Ihr Netzwerk aus, indem Sie Kompatibilit\u00e4t, Reichweite, Fasertyp und zukunftssichere Optionen vergleichen.<\/p>","protected":false},"author":1,"featured_media":5415,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5417","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5417","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=5417"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5417\/revisions"}],"predecessor-version":[{"id":11392,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5417\/revisions\/11392"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/5415"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=5417"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=5417"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=5417"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}