{"id":5407,"date":"2025-08-18T00:00:00","date_gmt":"2025-08-18T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/qsfp28-100g-psm4-transceivers-for-data-centers\/"},"modified":"2026-06-22T08:21:27","modified_gmt":"2026-06-22T08:21:27","slug":"qsfp28-100g-psm4-transceivers-for-data-centers","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/qsfp28-100g-psm4-transceivers-for-data-centers","title":{"rendered":"Freischalten der Hochdichte-100G-Konnektivit\u00e4t: Ihr Leitfaden zum 100G-PSM4-Optikmodul"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace.webp\" alt=\"QSFP28 100G PSM4 Transceivers\" class=\"wp-image-5405\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e8c59990135f47488a1f089f23f62ace-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\">Der unaufhaltsame Aufschwung von Cloud-Computing, KI und hyperskaligen Anwendungen erfordert immer schnellere, dichtere und kosteneffizientere Rechenzentrums-Verbindungen (DCI). Hier kommt das <\/span><span class=\"qc-p1-tag\"><strong>100G-PSM4 (Parallel Single-Mode 4-lane)<\/strong><\/span><span class=\"qc-p1-tag\" style=\"color: rgb(64, 64, 64);\"> Optikmodul \u2013 ein entscheidendes Arbeitstier, das effiziente 100-Gigabit-Ethernet-(100GbE)-Verbindungen antreibt. Dieser Leitfaden geht tief auf die Gr\u00fcnde ein, warum PSM4 eine zentrale L\u00f6sung f\u00fcr moderne Netzwerkinfrastrukturen ist.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udca1 Kenntnisse \u00fcber die PSM4-Technologie helfen Netzwerk-Ingenieuren, die beste Wahl f\u00fcr starke und wachsende Leistung zu treffen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Was ist ein 100G-PSM4-Optikmodul?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ein 100G-PSM4-Transceiver ist ein steckbares Optikmodul, das f\u00fcr 1<strong>00G-Ethernet<\/strong> \u00fcber <strong>Einmodenfaser <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>(SMF)<\/strong><\/a>. konzipiert ist. Es nutzt vier unabh\u00e4ngige optische Lanes, wobei jede mit 25 Gbit\/s (unter Verwendung von <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-non-return-to-zero-in-digital-communication\/\"><strong>NRZ-Modulation<\/strong><\/a>) am <strong>1310nm Wellenl\u00e4nge<\/strong>. arbeitet. Im Gegensatz zu <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-cwdm4-transceiver-efficient-2km-links\/\"><strong>100G<\/strong> <strong>CWDM4-Transceivern<\/strong><\/a>, die Wellenl\u00e4ngen auf ein einzelnes Faserpaar multiplexen, ben\u00f6tigt PSM4 <strong>acht Fasern<\/strong> (4 Tx, 4 Rx) \u2013 jeweils ein dediziertes Paar pro Lane. Dieser Ansatz der \u201cparallelen Optik\u201d bietet klare Vorteile.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Wichtige Vorteile der 100G-PSM4-Technologie<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Kosten-Effizienz:<\/strong> \ud83d\udcb0 PSM4 nutzt kosteng\u00fcnstigere optische Komponenten im Vergleich zu wellenl\u00e4ngenmultiplexenden L\u00f6sungen wie <strong>CWDM4<\/strong>. Die einfachere Optik f\u00fchrt zu einem <strong>kosteng\u00fcnstigeren 100G-Transceiver<\/strong>, was insbesondere bei gro\u00dffl\u00e4chigen Deployments von gro\u00dfer Bedeutung ist.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Geringe Latenz:<\/strong> \u26a1 Der direkte parallele \u00dcbertragungspfad minimiert die Komplexit\u00e4t der Signalverarbeitung und f\u00fchrt so zu <strong>extrem geringer Latenz<\/strong> \u2013 entscheidend f\u00fcr Hochfrequenzhandel, KI-Cluster und Finanzanwendungen.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Hohe Dichte und Skalierbarkeit:<\/strong> \u2b50 PSM4-Module weisen typischerweise das <strong>QSFP28-Formfaktor<\/strong>, auf und erm\u00f6glichen so eine hohe Portdichte an Switches und Routern. Sie eignen sich ideal f\u00fcr <strong>Leaf-Spine-Architekturen<\/strong> et <strong>Top-of-Rack-(ToR)-<\/strong> to <strong>Aggregations-\/Verteilungs-<\/strong> Switch-Verbindungen innerhalb einer Rechenzentrums-Halle.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Zuverl\u00e4ssige SMF-Leistung:<\/strong> \ud83d\ude80 Die Nutzung bew\u00e4hrter Single-Mode-Fasern gew\u00e4hrleistet eine <strong>gr\u00f6\u00dfere Reichweite<\/strong> (bis zu 500 m, oft bis zu 2 km mit hochwertigen Modulen wie den LINK-PP-Modulen) sowie <strong>\u00fcberlegene Leistung<\/strong> im Vergleich zu Multimode-L\u00f6sungen (wie SR4) bei vergleichbaren Entfernungen.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Ideale Einsatzgebiete f\u00fcr 100G-PSM4-Module<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Rechenzentrum-Verbindung (DCI):<\/strong> Innerhalb eines einzelnen Rechenzentrumsgeb\u00e4udes oder -campus (bis zu 500\u202fm\u20132\u202fkm).<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Hochleistungsrechnen <\/strong><a href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-hpc-high-performance-computing\/\" target=\"_blank\" rel=\"\"><strong>(HPC)<\/strong><\/a><strong> Cluster:<\/strong> Wo geringe Latenz und hohe Bandbreite zwingend erforderlich sind.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Enterprise-Netzwerk-Kern\/Aggregation:<\/strong> Aufr\u00fcstung von Backbone-Verbindungen f\u00fcr bandbreitenintensive Anwendungen.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Cloud-Anbieter-Infrastruktur:<\/strong> Verbindung von Servern, Speichersystemen und Switches in gro\u00dfskaligen Cloud-Umgebungen.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Finanznetzwerke:<\/strong> Unterst\u00fctzung von Low-Latency-Handelsplattformen.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd PSM4 vs. CWDM4: Die richtige 100G-Einmodenfaser-L\u00f6sung w\u00e4hlen<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Funktion<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>100G PSM4<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>100G CWDM4<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Technologie<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Parallel-Optik (4 Kan\u00e4le)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/wdm-optical-transceiver-module-applications\/\"><strong>WDM<\/strong><\/a> (4 Wellenl\u00e4ngen auf 1 Faserpaar)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Faseranzahl<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>8 Fasern<\/strong> (4 Sende-, 4 Empfangsfasern)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>2 Fasern<\/strong> (1 Sende-, 1 Empfangsfaser)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Reach<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Bis zu 500\u202fm (\u00fcblich), <strong>2\u202fkm+<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Bis zu 2\u202fkm<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cost<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Allgemein niedriger<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Latenz<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Ultra-niedrig<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Low<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Komplexit\u00e4t<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Niedriger (Optik)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00f6her (WDM-Multiplexer\/Demultiplexer erforderlich)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Am besten geeignet f\u00fcr<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hochdichte, kostenkritische intra-DC-Verbindungen &lt;\u202f2\u202fkm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Verbindungen mit knappem Faserangebot, bis zu 2\u202fkm<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd Warum LINK-PP 100G PSM4-Optikmodule w\u00e4hlen?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-1024x608.webp\" alt=\"LINK-PP 100G PSM4 Solutions\" class=\"wp-image-5406\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9-18x12.webp 18w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/39cdcc49922c4d8ebdd258250cf678e9.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Zuverl\u00e4ssigkeit, Leistung und Wert im Vordergrund stehen, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.link-pp.com\/\"><strong>LINK-PP<\/strong><\/a> \u00fcberzeugt. Unsere <strong>100G PSM4 QSFP28-Transceiver<\/strong> sind f\u00fcr h\u00f6chste Leistung konzipiert:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Garantierte Kompatibilit\u00e4t:<\/strong> Strenge Tests f\u00fcr nahtlose Kompatibilit\u00e4t mit f\u00fchrenden OEM-Switches (Cisco, Juniper, Arista usw.). Vermeiden Sie die Risiken generischer Module.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Hervorragende Qualit\u00e4t &amp; Zuverl\u00e4ssigkeit:<\/strong> Herstellung nach h\u00f6chsten Standards, um niedrige <strong>\ud83d\udccc Warum traditionelle Ma\u00dfe nicht ausreichten <\/strong><a href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-what-is-bit-error-rate\/\" target=\"_self\"><strong>(BER)<\/strong><\/a> und lange Betriebslebensdauer zu gew\u00e4hrleisten \u2013 ideal f\u00fcr <strong>mission-kritische Rechenzentrumsverbindungen<\/strong>.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Erweiterte Reichweite<\/strong> Our <strong>LINK-PP <\/strong><a href=\"https:\/\/www.l-p.com\/products\/488422.htm\" target=\"_blank\" rel=\"\"><strong>LQ-M31100-FR4C<\/strong><\/a> Modell erreicht zuverl\u00e4ssig <strong>bis zu 2\u202fkm<\/strong> \u00fcber Einmodenfaser und bietet damit gr\u00f6\u00dfere Flexibilit\u00e4t bei der Installation.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Kosteneinsparungen:<\/strong> Erleben Sie signifikante <strong>CAPEX-Einsparungen<\/strong> ohne Einbu\u00dfen bei Leistung oder Stabilit\u00e4t.<\/p><\/li>\n\n\n\n<li><p style=\"margin: 0px;\"><strong>Umfassende Garantie und Support:<\/strong> Unterst\u00fctzt durch branchenf\u00fchrenden Service und Garantie.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Nutzen Sie Ihr 100G-Potenzial mit LINK-PP!<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Optimieren Sie Ihre Rechenzentrums-Infrastruktur mit leistungsstarken, kosteneffizienten <strong>100G-Konnektivit\u00e4t<\/strong>. Egal, ob Sie neue Infrastruktur bereitstellen oder bestehende Verbindungen aufr\u00fcsten \u2013, <strong>LINK-PPs 100G PSM4-Transceiver<\/strong> bieten die zuverl\u00e4ssige, latenzarme Grundlage, die Sie ben\u00f6tigen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bereit, die LINK-PP 100G PSM4-Module zu entdecken?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u27a1\ufe0f <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488422.htm\"><strong>LQ-M31100-FR4C (2\u202fkm)<\/strong><\/a><br>\u27a1\ufe0f <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488423.htm\"><strong>LQ-M31100-LR4C (10\u202fkm)<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\ud83d\udcdd FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Was bedeutet PSM4?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PSM4 steht f\u00fcr \u201cParallel Single Mode 4-lane\u201d. Der Transceiver nutzt vier Fasern zum Senden und vier weitere Fasern zum Empfangen von Daten. Jeder Kanal \u00fcbertr\u00e4gt 25\u202fGbps.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kann der QSFP28 100G PSM4 mit vorhandenen Einmodenfasern betrieben werden?<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Ja, QSFP28 100G PSM4-Transceiver arbeiten mit herk\u00f6mmlichen Einmodenfasern (OS2). Viele Rechenzentren verwenden bereits diesen Fasertyp. Dadurch werden Upgrades vereinfacht und Kosten gespart.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">Wie \u00fcberwacht man die Funktionsf\u00e4higkeit eines PSM4-Transceivers?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Netzwerkadministratoren nutzen die digitale Diagnose\u00fcberwachung (DDM). DDM zeigt Werte wie Temperatur, Spannung und Signalst\u00e4rke an. Dadurch k\u00f6nnen Probleme fr\u00fchzeitig erkannt und behoben werden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Welchen Stecker verwendet der QSFP28 100G PSM4?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Der Transceiver verwendet einen MPO\/MTP-12-Stecker.<\/p><\/li>\n\n\n\n<li><p>Dieser Stecker fasst zw\u00f6lf Lichtwellenleiter in einer Reihe zusammen.<\/p><\/li>\n\n\n\n<li><p>Acht Lichtwellenleiter \u00fcbertragen Daten, vier werden nicht genutzt.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Ist der QSFP28 100G PSM4 hot-pluggable?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ja, den Transceiver kann man einstecken oder entfernen, ohne das Ger\u00e4t abzuschalten. Dadurch bleibt das Netzwerk w\u00e4hrend Upgrades oder Reparaturen weiterhin betriebsbereit.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Siehe auch<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-qsfp28-optical-transceivers-selection-guide\/\">Entdecken Sie 100G QSFP28-Optiktransceiver: SR4, LR4, CWDM4, PSM4 und mehr<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/psm4-vs-cwdm4-which-optical-transceiver-for-your-network\/\">PSM4 vs. CWDM4: Was sind die Unterschiede?<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-single-lambda-vs-4-channel-optical-modules-comparison\/\">100G Single-Lambda- gegen\u00fcber 4-Wellenl\u00e4ngen-Optikmodulen \u2013 wesentliche Unterschiede<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/100g-optical-transceiver-form-factors-guide\/\">Formfaktoren f\u00fcr 100G-Optiktransceiver: QSFP28, CFP, CFP2, CFP4?<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>QSFP28-100G-PSM4-Transceiver bieten Hochgeschwindigkeits-, kosteneffiziente 100G-Ethernet-Verbindungen \u00fcber Einmodenfasern und eignen sich ideal f\u00fcr Rechenzentren und Unternehmensnetzwerke.<\/p>","protected":false},"author":1,"featured_media":5405,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[13],"class_list":["post-5407","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-100g-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=5407"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5407\/revisions"}],"predecessor-version":[{"id":11245,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/5407\/revisions\/11245"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/5405"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=5407"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=5407"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=5407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}