{"id":4720,"date":"2025-10-14T11:12:00","date_gmt":"2025-10-14T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/difference-between-pse-and-pd-in-poe-networks\/"},"modified":"2026-06-22T09:02:40","modified_gmt":"2026-06-22T09:02:40","slug":"difference-between-pse-and-pd-in-poe-networks","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/difference-between-pse-and-pd-in-poe-networks","title":{"rendered":"PSE vs. PD \u2013 Power Sourcing Equipment vs. Powered Device in PoE"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9.webp\" alt=\"PSE vs. PD in PoE\" class=\"wp-image-4718\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/686d5d0598694700ab96d04e95124ff9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>PSE (Stromversorgungsausr\u00fcstung)<\/strong> liefert Gleichstrom \u00fcber Ethernet-Kabel; <strong>PD (Stromverbrauchendes Ger\u00e4t)<\/strong> verbraucht ihn. <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/ieee-802-3af-poe-standard-explained\/\"><strong>PoE-Standards<\/strong><\/a> (IEEE 802.3af\/at\/bt) definieren, wie viel Leistung bereitgestellt werden kann und wie PSE und PD Leistung sicher erkennen und aushandeln. Das Verst\u00e4ndnis von PSE vs. PD ist entscheidend f\u00fcr die korrekte Ger\u00e4teauswahl, Systemzuverl\u00e4ssigkeit, thermische und Kabelplanung sowie Konformit\u00e4t. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Klare Definitionen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Moderne Ethernet-Netzwerke \u00fcbertragen nicht nur Daten \u2013 sie liefern auch Strom.<br\/>Diese F\u00e4higkeit, bekannt als <strong>Power-over-Ethernet (PoE)<\/strong>, erm\u00f6glicht es Ger\u00e4ten wie drahtlosen Zugangspunkten, IP-Kameras und VoIP-Telefonen, sowohl Daten als auch Gleichstrom \u00fcber ein einzelnes Twisted-Pair-Kabel zu empfangen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Im Kern jedes PoE-Systems befinden sich zwei wesentliche Komponenten:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>PSE (Stromversorgungsausr\u00fcstung)<\/strong> \u2013 das Ger\u00e4t, das <em>Strom<\/em> liefert.<\/p><\/li><li><p><strong>PD (Stromverbrauchendes Ger\u00e4t)<\/strong> \u2013 das Ger\u00e4t, das <em>empf\u00e4ngt<\/em> liefert.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Das Verst\u00e4ndnis, wie diese beiden miteinander interagieren, ist entscheidend f\u00fcr die Planung effizienter, zuverl\u00e4ssiger und standardskonformer PoE-Netzwerke.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/poe-pse-power-sourcing-equipment-guide\/\">PSE \u2013 Power Sourcing Equipment<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>PSE<\/strong> ist jedes Ger\u00e4t, das Strom in die Ethernet-Twisted-Pairs einspeist: PoE-f\u00e4hige Switches (<strong>Endspan<\/strong>) oder Inline-Injektoren\/<strong>Midspans<\/strong>. Die PSE ist f\u00fcr Erkennung, Klassifizierung und die Verwaltung der Leistungsverteilung pro Port verantwortlich. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Aufgabe der PSE besteht darin, zu erkennen, ob ein angeschlossenes Ger\u00e4t PoE-kompatibel ist, dessen Leistungsanforderungen zu bestimmen und sicher die richtige Spannung und den richtigen Strom zu liefern. Erkennungs- und Klassifizierungsmechanismen stellen sicher, dass Nicht-PoE-Ger\u00e4te niemals versehentlich mit Strom versorgt werden, wodurch empfindliche Ger\u00e4te gesch\u00fctzt werden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>H\u00e4ufige PSE-Typen:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Endspan-PSE:<\/strong> Direkt in einen PoE-Switch-Port integriert.<\/p><\/li><li><p><strong>Midspan-PSE:<\/strong> Externer Injektor, der zwischen einem Nicht-PoE-Switch und dem PD platziert wird.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">PSE-Ger\u00e4te entsprechen IEEE-Standards, die maximale Ausgangsleistung pro Port und Aushandlungsverfahren festlegen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" ><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/poe-pd-powered-device-guide\/\">PD \u2013 Powered Device<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ein PD ist jedes Ger\u00e4t, das \u00fcber das Ethernet-Kabel Strom von einer PSE erh\u00e4lt, z.\u202fB., <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-a-wireless-access-point-wap\/\">drahtlose Zugangspunkte (WAPs)<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/ip-internet-protocol-cameras-overview\/\">IP-Kameras<\/a>, VoIP-Telefone, kleine Switches oder IoT-Ger\u00e4te. PDs m\u00fcssen eine definierte Signatur pr\u00e4sentieren, damit die PSE sie erkennen und sicher mit Strom versorgen kann.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Jedes PD enth\u00e4lt eine <strong>PoE-Schnittstelle<\/strong> mit Erkennungsschaltung und DC-DC-Wandlung, wodurch es sicher und effizient aus der zugef\u00fchrten Spannung (typischerweise 44\u201357 V DC) betrieben werden kann.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Zusammenspiel von PSE und PD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Eine PoE-Verbindung beginnt mit einem <strong>Handshake<\/strong> \u2013 einem Erkennungsprozess, um zu best\u00e4tigen, ob das angeschlossene Ger\u00e4t PoE unterst\u00fctzt. Die PSE sendet eine kleine Spannung, um den <em>Signaturwiderstand<\/em>.<br\/>des PD zu identifizieren. <strong>Klassifizierung<\/strong>, um festzustellen, wie viel Leistung das PD ben\u00f6tigt (z.\u202fB. Klasse 0\u20138).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sobald dies best\u00e4tigt ist, legt die PSE die volle Betriebsspannung an und beginnt mit der Stromversorgung, w\u00e4hrend der interne Wandler des PD die zugef\u00fchrte Leistung f\u00fcr seine Schaltungen stabilisiert.<br\/>Moderne PoE+- und PoE++-Systeme verwenden m\u00f6glicherweise auch <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/lldp-in-power-over-ethernet-systems\/\"><strong>LLDP (Link-Layer-Discovery-Protokoll)<\/strong><\/a> zur dynamischen Aushandlung der Leistung, was Energieeffizienz und Netzwerksteuerung verbessert.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >PoE-Standards und Leistungsstufen<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 135px;\"\/><col style=\"width: 99px;\"\/><col style=\"width: 105px;\"\/><col style=\"width: 114px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p><strong>Standard<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p><strong>Type<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p><strong>Maximale PSE-Leistung<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p><strong>Verf\u00fcgbare PD-Leistung<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Typische Anwendungen<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p>IEEE 802.3af<br\/><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/ieee-802-3af-poe-standard-explained\/\">(PoE)<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p>Typ 1<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p>15.4W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p>12,95 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>IP-Telefone, Basis-WAPs<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p>IEEE 802.3at<br\/><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/ieee-802-3at-power-over-ethernet-plus-standard\/\">(PoE+)<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p>Typ 2 <\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p>30W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p>25.5W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PTZ-Kameras, Dual-Band-APs<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p>IEEE 802.3bt<br\/><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-ieee-802-3-bt-poe-standard\/\">(PoE++)<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p>Typ 3<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p>60W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p>51W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Thin Clients, POS-Terminals<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"135\"><p>IEEE 802.3bt<br\/>(PoE++)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"99\"><p>Typ 4 <\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"105\"><p>90\u2013100 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"114\"><p>71\u201373 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Pan-Tilt-Zoom-Kameras, LED-Panels, Zugangskontrollsysteme<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Note:<\/strong> Der Unterschied zwischen PSE- und PD-Leistung resultiert aus Verlusten durch Kabelwiderstand.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Standards gew\u00e4hrleisten Kompatibilit\u00e4t zwischen Herstellern und sch\u00fctzen Ger\u00e4te vor elektrischen Fehlfunktionen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Praktische \u00dcberlegungen bei der Auswahl von PSE und PD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Match the standard:<\/strong><br\/>Stellen Sie sicher, dass Ihre PSE die Leistungsklasse des PD unterst\u00fctzt. Die Verwendung eines PoE-(802.3af)-Switches f\u00fcr eine PoE+-Kamera f\u00fchrt zu einem Stromausfall.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Plan for power budget:<\/strong><br\/>Switches teilen die Gesamtleistung auf alle Ports auf; halten Sie stets eine Reserve f\u00fcr Spitzenlasten ein.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Check cabling:<\/strong><br\/>H\u00f6here Leistung <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-ieee-802-3-bt-poe-standard\/\">(PoE++)<\/a> erfordert Cat6- oder Cat6a-Kabel, um Erw\u00e4rmung und Verluste zu reduzieren.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Thermal and safety management:<\/strong><br\/>Bei Hochleistungsinstallationen sollten die IEEE-Empfehlungen zur Kabelb\u00fcndelung und Leistungsabsenkung (derating) beachtet werden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u2714 Use compliant components:<\/strong><br\/>Zertifizierte <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491473.htm\">PoE-RJ45-Steckverbinder<\/a> und Magnete gew\u00e4hrleisten Isolation, Unterdr\u00fcckung elektromagnetischer St\u00f6rungen (EMI) und sichere Stromf\u00fchrung.<\/p>","protected":false},"excerpt":{"rendered":"<p>Learn the difference between PSE and PD in PoE networks, how detection &#038; classification work, and which LINK-PP PoE RJ45 products suit your WAP, camera or VoIP deployment.<\/p>","protected":false},"author":1,"featured_media":4719,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[22],"class_list":["post-4720","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-integrated-rj45-connectors"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/4720","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=4720"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/4720\/revisions"}],"predecessor-version":[{"id":11355,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/4720\/revisions\/11355"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/4719"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=4720"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=4720"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=4720"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}