{"id":4545,"date":"2025-10-31T11:12:00","date_gmt":"2025-10-31T11:12:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/25gbase-ieee-802-3by-single-lane-25gbe-standard\/"},"modified":"2026-06-22T05:43:36","modified_gmt":"2026-06-22T05:43:36","slug":"25gbase-ieee-802-3by-single-lane-25gbe-standard","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/25gbase-ieee-802-3by-single-lane-25gbe-standard","title":{"rendered":"25GBASE IEEE 802.3by: Der Single-Lane-25-Gb-Ethernet-Standard"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0.webp\" alt=\"What Is IEEE 802.3by?\" class=\"wp-image-4542\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ca1377e01de94208976debf546751df0-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Die explosionsartige Zunahme von Cloud-Diensten, Virtualisierung, KI-Workloads und Hochdichteserver-Deployments hat Rechenzentren veranlasst, schnellere und effizientere Ethernet-Technologien zu verfolgen. Um die L\u00fccke zwischen 10-GbE und den kostenintensiven 40-\/100-GbE-L\u00f6sungen zu schlie\u00dfen, f\u00fchrte das IEEE ein <strong>IEEE 802.3by<\/strong>, das eine <strong>einlanige 25-Gb\/s-Ethernet-Physikalschicht definiert<\/strong>, allgemein bekannt als <strong>25GBASE<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dieser Artikel erl\u00e4utert, was IEEE 802.3by ist, warum es wichtig ist und wie es einen skalierbaren 25-GbE-Einsatz erm\u00f6glicht \u2013 sowie, wie <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">die SFP28-Module von LINK-PP<\/a> dieses \u00d6kosystem unterst\u00fctzen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Was ist IEEE 802.3by?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 802.3by ist eine Erg\u00e4nzung zum IEEE-802.3-Ethernet-Standard, die die Spezifikationen f\u00fcr <strong>25-Gigabit-Ethernet \u00fcber eine einzelne elektrische Leitung definiert<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Es standardisiert die 25-Gb\/s-\u00dcbertragung \u00fcber:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>direkt verbundene Kupferkabel (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-breakout-dac-and-why-breakout-dac-matters\/\">DAC<\/a>)<\/p><\/li><li><p>Backplane-Kan\u00e4le<\/p><\/li><li><p>Multimode-Glasfaser<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ziel: einen einfachen, kosteneffizienten und hochdichten Upgrade-Pfad von 10G zu 25G bereitzustellen, insbesondere bei Verbindungen zwischen Rechenzentrums-Servern und Leaf-Switches.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Warum wurde 25GBASE entwickelt?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Effizienz einer einzelnen Leitung<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fr\u00fchere 40-GbE-Verbindungen verwendeten <strong>4 \u00d7 10-Gb\/s-Leitungen<\/strong>. Im Gegensatz dazu nutzt 25GBASE <strong>1 \u00d7 25-Gb\/s-Leitung<\/strong>, und bietet damit:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>H\u00f6here Bandbreite pro Leitung<\/p><\/li><li><p>Geringerem Stromverbrauch<\/p><\/li><li><p>Geringere Kosten pro Port<\/p><\/li><li><p>Einfachere Verkabelung und Optik<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Idealer Zwischenschritt von 10G<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">25 Gb\/s liefert <strong>das 2,5-fache der Bandbreite von 10 Gb\/s<\/strong> bei nur geringf\u00fcgigem Anstieg von Stromverbrauch und Kosten \u2013 ideal f\u00fcr Hochdichte-Server-I\/O.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Skalierbarer Pfad zu 50\/100 GbE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">25G bildet den Baustein f\u00fcr:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>50G-Ethernet (2 \u00d7 25G-Leitungen)<\/p><\/li><li><p>100-G-Ethernet (<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472118.htm\">4 \u00d7 25G-Leitungen<\/a>)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Es handelt sich um eine grundlegende Geschwindigkeit in modernen Rechenzentrums-Fabrics.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Wichtige technische Merkmale von 25GBASE (IEEE 802.3by)<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 303px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Funktion<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Beschreibung<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>\u00dcbertragungsrate<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>25 Gb\/s pro Lane<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Codierung<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>64b\/66b<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Optionales RS-FEC<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Medium<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kupfer, Backplane, Multimode-Glasfaser<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Modulformat<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>SFP28<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"303\"><p>Zielanwendung<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Server-zu-Switch-Interconnects<br><\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 25GBASE-Schnittstellenvarianten<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Standard<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Medium<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Einsatzgebiet<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>25GBASE-CR \/ CR-S<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Twinax-Kupfer-DAC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Kurzstreckenverbindungen (1\u20135 m) innerhalb eines Racks<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>25GBASE-KR \/ KR-S<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>R\u00fcckwandplatine<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Backplane-Verbindungen zwischen Servern und Line-Cards<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476099.htm\">25GBASE-SR<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Multimode-Glasfaser<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Bis zu ca. 100 m auf OM4-Glasfaser<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476046.htm\">25GBASE-LR<\/a>*<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Einmodenglasfaser<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ca. 10 km (*in sp\u00e4teren Erg\u00e4nzungen definiert)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Typische Einsatzszenarien<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Rechenzentrums-Leaf-Spine-Netzwerke<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">25GBASE hilft Betreibern, Ost-West-Verkehr zu skalieren, w\u00e4hrend Infrastrukturkosten und -platzbedarf kontrolliert werden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Server-zu-Top-of-Rack-(ToR)-Verbindungen<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Server mit 25G-NICs verbinden sich \u00fcber SFP28-Optiken oder DAC-Kabel mit ToR-Switches.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Aggregation und <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-you-need-to-know-about-edge-computing-key-benefits-uses\/\">Edge-Computing<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">25G-f\u00e4hige Uplinks bieten das richtige Gleichgewicht zwischen Durchsatz und Kosten, insbesondere in Edge- und KI-f\u00e4higen Architekturen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Best Practices f\u00fcr den Einsatz von 25GBASE<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Die richtige \u00dcbertragungsmedienwahl<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>1\u20135 m:<\/strong> DAC-Kupfer (25GBASE-CR)<\/p><\/li><li><p><strong>Bis zu ca. 100 m:<\/strong> Multimode-Glasfaser (25GBASE-SR + OM4)<\/p><\/li><li><p><strong>Campus-\/Langstrecken:<\/strong> Einmoden-Glasfaser (25GBASE-LR oder sp\u00e4tere Spezifikationen)<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Hardware-Interoperabilit\u00e4t validieren<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Stellen Sie sicher, dass Switches, NICs und <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">optische module<\/a> alle mit IEEE 802.3by kompatibel sind.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >FEC-Anforderungen ber\u00fccksichtigen<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Aktivieren Sie RS-FEC dort, wo Link-Marge oder elektromagnetische Umgebungen zus\u00e4tzliche Robustheit erfordern.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 SFP28-Module und L\u00f6sungen von LINK-PP<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77.webp\" alt=\"LINK-PP SFP28 Modules\" class=\"wp-image-4543\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/dbd37648365f4364bc8c6a1ec2ef4a77-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Das prim\u00e4re Formfaktor f\u00fcr 25GBASE ist <strong>SFP28<\/strong> \u2014 mechanisch \u00e4hnlich dem SFP+, jedoch mit verbesserten elektrischen Spezifikationen f\u00fcr 25-Gb\/s-Signale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP bietet <strong>IEEE-802.3by-konforme 25G-SFP28-Optikmodule und DAC-Kabel<\/strong> f\u00fcr Hochdichte-Rechenzentrums-Deployments:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udd17<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\"><strong>LINK-PP-25G-SFP28-Transceiver<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wichtige Vorteile der LINK-PP-25G-Module:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Niedrige Latenz und hohe Stabilit\u00e4t der Verbindung<\/p><\/li><li><p>OEM-kompatible Integration mit f\u00fchrenden Switch-Marken<\/p><\/li><li><p>Nachgewiesene Zuverl\u00e4ssigkeit in hyperskaligen und Unternehmens-Rechenzentren<\/p><\/li><li><p>Wettbewerbsf\u00e4hige Preise f\u00fcr Gro\u00dfserien-Deployments<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd39 Zusammenfassung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der IEEE-802.3by-Standard erm\u00f6glicht <strong>effiziente, skalierbare, einlanige 25-GbE-<\/strong> Deployments \u2013 mittlerweile eine Kern-Technologie in modernen Rechenzentren. Mit einfacher Verkabelung, starker R\u00fcckw\u00e4rtskompatibilit\u00e4t zu 10G sowie zukunftssicherer Skalierbarkeit auf 50\/100G und 25GBASE ist 25GBASE ein wesentlicher Meilenstein in der Netzwerkentwicklung.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr Ingenieure und Planer, die auf 25 GbE umsteigen, <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476046.htm\"><strong>SFP28-Module<\/strong><\/a><strong> et <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26454-dac-aoc-aec-cables.htm\"><strong>DAC-L\u00f6sungen<\/strong><\/a> bieten zuverl\u00e4ssige, kosteng\u00fcnstige Konnektivit\u00e4t, die vollst\u00e4ndig mit den IEEE-802.3by-Spezifikationen \u00fcbereinstimmt.<\/p>","protected":false},"excerpt":{"rendered":"<p>Erforschen Sie den IEEE-802.3by-Standard f\u00fcr 25GBASE-Ethernet. Lernen Sie Spezifikationen, Medientypen, Anwendungsszenarien sowie die Unterst\u00fctzung zuverl\u00e4ssiger 25GbE-Netzwerke durch LINK-PP-SFP28-Module kennen.<\/p>","protected":false},"author":1,"featured_media":4544,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[16,26],"class_list":["post-4545","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-link-pp-25g-sfp28-optical-modules","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/4545","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=4545"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/4545\/revisions"}],"predecessor-version":[{"id":10951,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/4545\/revisions\/10951"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/4544"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=4545"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=4545"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=4545"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}