{"id":3818,"date":"2025-09-03T00:00:00","date_gmt":"2025-09-03T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/mode-conditioning-patch-cables-how-they-work-in-networks\/"},"modified":"2026-06-22T07:47:30","modified_gmt":"2026-06-22T07:47:30","slug":"mode-conditioning-patch-cables-how-they-work-in-networks","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/mode-conditioning-patch-cables-how-they-work-in-networks","title":{"rendered":"Was sind Mode-Conditioning-Patchkabel und wie funktionieren sie?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f.webp\" alt=\"What Are Mode Conditioning Patch Cables\" class=\"wp-image-3815\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/e804416210894e9c9828e14e16210c3f-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Haben Sie jemals einen Gigabit-LX- oder 10G-LR-Optiktransceiver installiert und unerwartete Fehler, hohe D\u00e4mpfung oder instabile Verbindungen festgestellt? Die Ursache liegt m\u00f6glicherweise nicht in Ihrer Ausr\u00fcstung, sondern in einer grundlegenden Inkompatibilit\u00e4t Ihrer Lichtwellenleiter-Typen. Hier kommt ein kleiner, aber leistungsstarker Held ins Spiel: das <strong>Mode-Conditioning-Patchkabel (MCP)<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In dieser Anleitung kl\u00e4ren wir auf, <strong>was ein Mode-Conditioning-Patchkabel ist,<\/strong>, warum es in bestimmten Netzwerkszenarien unverzichtbar ist und wie es Ihnen eine Welt von Konnektivit\u00e4tsproblemen erspart. Wir untersuchen zudem, wie es mit Hochleistungskomponenten wie <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>LINK-PP optische Transceiver<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Wichtige Erkenntnisse<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Mode-Conditioning-Patchkabeln<\/strong> zusammenarbeitet, um Einmoden-Ger\u00e4te mit Multimode-Fasern zu betreiben. Sie beheben Signalprobleme wie Differential Mode Delay.<\/p><\/li><li><p>Diese Kabel verbessern das Signal und reduzieren Fehler. Dadurch arbeiten Netzwerke schneller und zuverl\u00e4ssiger \u2013 insbesondere bei Gigabit-Ethernet.<\/p><\/li><li><p>Die Kabel verf\u00fcgen \u00fcber einen speziellen Abschnitt mit Einmoden-Anteil. Dieser verschiebt das Lichtsignal, um Verzerrungen zu verringern und den Datenfluss zu optimieren.<\/p><\/li><li><p>Verbinden Sie stets das Einmoden-Ende mit dem Transceiver und das Multimode-Ende mit der Faserinfrastruktur, um Netzwerkprobleme zu vermeiden.<\/p><\/li><li><p>Reinigen Sie die Stecker vor der Verwendung. Biegen Sie die Kabel nicht scharf. Testen Sie die Verbindung nach der Installation, um die Netzwerkstabilit\u00e4t zu gew\u00e4hrleisten.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Warum ben\u00f6tigen wir ein \u201cspezielles\u201d Kabel? Das Multimode- vs. Einmoden-Problem<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Um die L\u00f6sung zu verstehen, m\u00fcssen wir zun\u00e4chst das Problem begreifen. Lichtwellenleiter gibt es haupts\u00e4chlich in zwei Typen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/om1-om2-om3-om4-om5-multimode-fiber-guide\/\"><strong>Multimode-Glasfaser (MMF)<\/strong><\/a><strong>:<\/strong> Besitzt einen gr\u00f6\u00dferen Kern, wodurch mehrere Lichtmodi (Pfade) gleichzeitig laufen k\u00f6nnen. Es ist f\u00fcr kurze Entfernungen und hochbandbreitige Anwendungen innerhalb von Geb\u00e4uden oder Campusnetzwerken konzipiert. G\u00e4ngige Typen sind <strong>OM1, OM2, OM3 und OM4<\/strong>.<\/p><\/li><li><p style=\"margin: 0px;\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-single-mode-fiber-and-how-does-it-work\/\"><strong>Einmoden-Faser (SMF)<\/strong><\/a><strong>:<\/strong> Hat einen deutlich kleineren Kern, sodass nur ein Lichtmodus geradlinig durchl\u00e4uft. Es ist f\u00fcr Langstreckenkommunikation \u2013 etwa zwischen St\u00e4dten \u2013 ausgelegt.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Das Problem entsteht, wenn Sie versuchen, einen <strong>Long-Reach-(LX\/LR)-Transceiver<\/strong> (der f\u00fcr Einmodenfasern konzipiert ist) mit einer <strong>Multimode-Glasfaser (MMF)<\/strong> Kabelanlage. Dies ist \u00fcblich in \u00e4lteren Geb\u00e4uden, die mit Multimodefasern (MMF) verdrahtet sind und eine Verbindung zu einer neuen Singlemode-Faser-(SMF-)Hauptleitung ben\u00f6tigen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Das Laserlicht des LX\/LR-Transceivers koppelt in den gro\u00dfen MMF-Kern ein. Dies kann ein Ph\u00e4nomen namens <strong>Differenzielle Modenverz\u00f6gerung (DMD)<\/strong>, hervorrufen, bei dem Lichtpulse sich w\u00e4hrend der Ausbreitung verbreitern und verzerren, was zu Jitter, Fehlern und vollst\u00e4ndigem Linkausfall f\u00fchrt. Dies ist besonders problematisch bei <strong>OM3- und OM4-Fasern<\/strong> et <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>10G-LR-Modulen<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Wie funktioniert ein Mode-Conditioning-Patchkabel?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"318\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028.webp\" alt=\"Mode Conditioning Patch Cables\" class=\"wp-image-3816\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-300x80.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-1024x271.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-768x204.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/4deb34a51d504b858a9c85430a080028-18x5.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>Mode-Conditioning-Patchkabel<\/strong> ist ein geschickt konstruiertes <strong>Duplex-Faser-Patchkabel<\/strong> , das diese Inkompatibilit\u00e4t auf der physikalischen Schicht l\u00f6st. Es wird manchmal auch als <em>Mode-Conditioning-Jumper<\/em>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">bezeichnet. Sein \u201eZauber\u201c liegt in seiner Konstruktion auf der Sendeseite (Tx):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Ein Kabelast ist ein Standard- <strong>Singlemode-Anschluss<\/strong> , der in Ihren Transceiver eingesteckt wird.<\/p><\/li><li><p style=\"margin: 0px;\">Der andere Ast ist ein <strong>Multimode-Anschluss<\/strong> mit einer pr\u00e4zisen, versetzten Fusionssplei\u00dfstelle wenige Meter vom Ende entfernt.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Konstruktion zwingt das Laserlicht, zun\u00e4chst eine kurze Strecke auf der Singlemode-Faser zur\u00fcckzulegen. Anschlie\u00dfend wird es gezielt am Splei\u00dfpunkt in die <strong>Mitte des Multimode-Faserkerns<\/strong> eingekoppelt. Bis das Signal Ihre bestehende MMF-Kabelanlage erreicht, hat es sich stabilisiert \u2013 wodurch der DMD-Effekt effektiv eliminiert wird und eine saubere, zuverl\u00e4ssige Daten\u00fcbertragung erm\u00f6glicht wird.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Wichtige Anwendungen und Einsatzf\u00e4lle:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\">Verbinden <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>1000BASE-LX-SFP-Modul<\/strong><\/a> to <strong>OM1\/OM2\/OM3-<\/strong> Multimodefaser.<\/p><\/li><li><p style=\"margin: 0px;\">Verbinden <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>10GBASE-LR-SFP+-Module<\/strong><\/a> to <strong>OM3\/OM4<\/strong> Multimodefaser.<\/p><\/li><li><p style=\"margin: 0px;\">Erweiterung der Reichweite von LX\/LR-Transceivern auf MMF \u00fcber ihre typische, durch DMD begrenzte Distanz hinaus.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Mode-Conditioning vs. Standard-Patchkabel: Ein kurzer Vergleich<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p><strong>Funktion<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Standard-Patchkabel<\/strong><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><strong>Mode-Conditioning-Patchkabel<\/strong><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Prim\u00e4re Funktion<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Verbindet gleiche Fasertypen (SMF-SMF oder MMF-MMF)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Verbindet unterschiedliche Fasertypen (SMF-Transceiver mit MMF-Kabel)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Innenaufbau<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Durchg\u00e4ngiger Fasertyp<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enth\u00e4lt eine pr\u00e4zise <strong>versetzte Fusionssplei\u00dfstelle<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Einsatzgebiet<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Standard-Anschlussart (\u201ein-type\u201c)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Modernisierung bestehender Netzwerke<\/strong>, spezifische Transceiver-Anforderungen<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Verhindert DMD?<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Nein<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><strong>Yes<\/strong><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Cost<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lower<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Etwas h\u00f6her<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Integration mit LINK-PP-Optiktransceivern f\u00fcr optimale Leistung<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"719\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f.jpg\" alt=\"optical transceivers\" class=\"wp-image-3817\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f.jpg 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-300x180.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-1024x614.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-768x460.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ab15e605dd5a45cc9008a6ae30a4e10f-18x12.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bei der Errichtung eines zuverl\u00e4ssigen und leistungsstarken Netzwerks muss jedes Komponente harmonisch zusammenarbeiten. Die Verwendung eines hochwertigen Mode-Conditioning-Kabels ist entscheidend, um das volle Potenzial Ihrer <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Glasfaser-Transceiver zu erschlie\u00dfen.<\/strong><\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Sie beispielsweise ein <strong>LINK-PP <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>SFP-10G-LR<\/strong><\/a> Modul verwenden, um eine bestehende OM3-Multimode-Hauptleitung anzuschlie\u00dfen, ist ein Mode-Conditioning-Patchkabel nicht nur empfehlenswert; es ist h\u00e4ufig zwingend erforderlich, um eine stabile Verbindung sicherzustellen. Dasselbe gilt f\u00fcr ein<strong> <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476763.htm\"><strong>SFP-1G-LX<\/strong><\/a> Modul an \u00e4lterem OM1-Kabel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Profi-Tipp:<\/strong> Pr\u00fcfen Sie stets das Datenblatt Ihres <strong>LINK-PP-kompatiblen Transceivers.<\/strong>. Darin wird der erforderliche Fasertyp angegeben und h\u00e4ufig ausdr\u00fccklich auf die Notwendigkeit eines Mode-Conditioning-Patchkabels bei Anschluss an Multimodefasern (MMF) hingewiesen. Die ordnungsgem\u00e4\u00dfe Implementierung dieser Konfiguration ist eine bew\u00e4hrte Methode f\u00fcr <strong>Netzwerkzuverl\u00e4ssigkeit<\/strong> und zur Minimierung von <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-what-is-bit-error-rate\/\"><strong>\u00fcber den gesamten 80\u00a0km-Bereich. Maximieren Sie Ihr<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 Ben\u00f6tigen Sie eines? Wichtige Erkenntnisse<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p style=\"margin: 0px;\"><strong>Sie ben\u00f6tigen ein Mode-Conditioning-Patchkabel, wenn:<\/strong> Sie einen <strong>Long-Reach-(LX-, LR-, ER-)<\/strong> SFP-, SFP+- oder GBIC-Transceiver mit einer <strong>Multimode-Glasfaser (MMF)<\/strong> Kabelstrecke verbinden.<\/p><\/li><li><p style=\"margin: 0px;\"><strong>Sie ben\u00f6tigen keines, wenn:<\/strong> Sie einen Transceiver mit demselben Fasertyp verbinden, f\u00fcr den er konzipiert wurde (z.\u202fB. LX mit SMF oder SX mit MMF).<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Die Investition in die richtige Kabelinfrastruktur stellt sicher, dass Ihr Netzwerk effizient l\u00e4uft, Ausfallzeiten reduziert und Ihre Investition in hochwertige Hardware wie <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>LINK-PP-Optikmodule<\/strong><\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" ><strong>\u27a4 FAQ<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Was ist der Hauptzweck eines Mode-Conditioning-Patchkabels?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ein Mode-Conditioning-Patchkabel erm\u00f6glicht es Singlemode-Transceivern, mit Multimode-Faser zu arbeiten. Es hilft, Signalprobleme wie differentielle Modenverz\u00f6gerung (Differential Mode Delay) zu reduzieren. Dadurch bleibt die Daten\u00fcbertragung in gemischten Fasernetzwerken reibungslos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >K\u00f6nnen Mode-Conditioning-Patchkabel mit jedem faseroptischen System verwendet werden?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nein, diese Kabel funktionieren am besten beim Anschluss von Singlemode-Ger\u00e4ten an Multimode-Faser. Sie bringen keinen Nutzen in Systemen, die ausschlie\u00dflich Singlemode- oder ausschlie\u00dflich Multimode-Faser verwenden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Wie kann man erkennen, welches Ende des Kabels f\u00fcr Singlemode ausgelegt ist?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Die meisten Kabel weisen am Singlemode-Ende eine gelbe Abdeckung (Boot) oder eine Kennzeichnung auf. Der Benutzer sollte diese Markierungen stets vor dem Anschlie\u00dfen des Kabels \u00fcberpr\u00fcfen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Was passiert, wenn das Kabel falsch herum installiert wird?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wird das Kabel r\u00fcckw\u00e4rts angeschlossen, funktioniert das Netzwerk m\u00f6glicherweise nicht. Das Signal kann schwach oder vollst\u00e4ndig verloren gehen. Verbinden Sie stets das Singlemode-Ende mit dem Transceiver.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Unterst\u00fctzen Mode-Conditioning-Patchkabel Hochgeschwindigkeitsnetzwerke?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ja, diese Kabel unterst\u00fctzen Hochgeschwindigkeitsverbindungen wie Gigabit-Ethernet und 10-Gigabit-Ethernet. Sie tragen dazu bei, Signale in schnellen Netzwerken klar und stark zu halten.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Tipp: Testen Sie nach der Installation eines Mode-Conditioning-Patchkabels stets die Verbindung, um sicherzustellen, dass die Verbindung einwandfrei funktioniert.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Mode-Conditioning-Patchkabel erm\u00f6glichen es Singlemode-Ger\u00e4ten, mit Multimode-Faser zu arbeiten, und reduzieren Signalverzerrungen sowie differentielle Modenverz\u00f6gerung (Differential Mode Delay) in Netzwerken.<\/p>","protected":false},"author":1,"featured_media":3815,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[26],"class_list":["post-3818","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=3818"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3818\/revisions"}],"predecessor-version":[{"id":11185,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3818\/revisions\/11185"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/3815"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=3818"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=3818"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=3818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}