{"id":3578,"date":"2025-11-28T00:00:00","date_gmt":"2025-11-28T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/what-is-physical-medium-dependent-pmd\/"},"modified":"2026-06-22T04:35:06","modified_gmt":"2026-06-22T04:35:06","slug":"what-is-physical-medium-dependent-pmd","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-physical-medium-dependent-pmd","title":{"rendered":"PMD (Physical Medium Dependent) Praktische Anleitung f\u00fcr optische Verbindungen"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe.webp\" alt=\"PMD (Physical Medium Dependent)\" class=\"wp-image-3574\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/0cd5f86bb90c45a09b502f640fbf4abe-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>physikalische Medium Dependent (PMD)<\/strong> Die Subschicht ist eines der wichtigsten Elemente der Ethernet-Physikalschicht, wird jedoch h\u00e4ufig missverstanden. PMD definiert, wie Bits physikalisch \u00fcber ein bestimmtes Medium \u2013 Einmodenfaser, Multimodenfaser, direkt angekoppeltes Kupfer oder elektrische R\u00fcckwand \u2013 \u00fcbertragen und empfangen werden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr Netzwerkdesigner, Testingenieure und Beschaffungsteams ist das Verst\u00e4ndnis von PMD unerl\u00e4sslich, da PMD-Spezifikationen unmittelbar Einfluss nehmen auf <strong>Interoperabilit\u00e4t<\/strong>, <strong>Reichweite<\/strong>, <strong>die Signalintegrit\u00e4t<\/strong>, und <strong>Auswahl der Transceiver<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dieser Leitfaden bietet eine professionelle, normenkonforme Erkl\u00e4rung von PMD einschlie\u00dflich der Parameter, die Sie bei der Auswahl bewerten m\u00fcssen: <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">Optische Transceiver<\/a> z.\u202fB. SFP-, SFP+- und QSFP-Module.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Was ist die Physical Medium Dependent (PMD)-Unterschicht?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>physikalische Medium Dependent (PMD)<\/strong> Die Unterschicht ist der unterste funktionale Block der <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">IEEE 802.3<\/a> PHY. Sie definiert die <strong>optischen oder elektrischen Eigenschaften<\/strong> , die f\u00fcr eine erfolgreiche \u00dcbertragung \u00fcber das gew\u00e4hlte Medium erforderlich sind.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In realen Produkten entspricht PMD der Front-End-Schnittstelle eines optischen Transceivers \u2013 also dessen Laser, Empf\u00e4nger-Fotodiode, Modulationschaltkreis sowie verwandte Komponenten.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Was PMD steuert<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Die optische Wellenl\u00e4nge und spektrale Breite<\/p><\/li><li><p>Durchschnittliche Sendeleistung (Tx) und Einspeisebedingungen<\/p><\/li><li><p>Empfindlichkeit (Rx) und \u00dcberlastgrenzen des Empf\u00e4ngers<\/p><\/li><li><p>Optische <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/optical-transceiver-return-loss-back-reflection-guide\/\">R\u00fcckflussd\u00e4mpfung<\/a> und Extinktionsverh\u00e4ltnis<\/p><\/li><li><p>Unterst\u00fctzter Fasertyp und \u00dcbertragungsstrecke<\/p><\/li><li><p>Elektrische Sende-\/Empfangs-Augenmasken (f\u00fcr elektrische PHYs)<\/p><\/li><li><p>Definitionen von Messpunkten f\u00fcr Konformit\u00e4tsmessungen<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">PMD fungiert als <strong>Br\u00fccke zwischen der standardisierten PHY-Logik und der physikalischen Welt<\/strong>, und stellt sicher, dass Transceiver verschiedener Hersteller auf derselben Faserinfrastruktur interoperabel sind.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f PMD im Vergleich zu anderen PHY-Unterschichten<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Ethernet-PHY-Architektur umfasst typischerweise:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/\"><strong>PCS (Physical Coding Sublayer)<\/strong> <\/a>\u2014 Codierung, 64b\/66b, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/fec-forward-error-correction-in-optical-communication\/\">FEC<\/a>, \u2014 Kanalzuweisung<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\"><strong>PMA (Physikalische Medienanbindung)<\/strong><\/a> \u2014 Seriellisierung\/Deserialisierung, Taktr\u00fcckgewinnung<\/p><\/li><li><p><strong>PMD (Medienabh\u00e4ngige physikalische Schicht)<\/strong> \u2014 mediumspezifische optische\/elektrische Parameter<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">PMD ist der Teil, der direkt mit dem optischen Budget und dem Mediumstyp verkn\u00fcpft ist.<br\/>Ein einzelner MAC kann mehrere PMDs unterst\u00fctzen (z.\u202fB. SR, LR, ER), wobei jedes auf eine andere Reichweite oder ein anderes Medium optimiert ist.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Warum PMD in realen Netzwerken wichtig ist<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34.webp\" alt=\"Why PMD Matters in Real Networks\" class=\"wp-image-3575\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/27e048578ea044bf9f40c798076a3c34-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Garantierte Interoperabilit\u00e4t<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nur Module, die denselben PMD-Spezifikationen entsprechen, verbinden sich zuverl\u00e4ssig. Wellenl\u00e4nge, Leistungspegel und Empfindlichkeit m\u00fcssen den IEEE-Anforderungen entsprechen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Vorhersagbare \u00dcbertragungsreichweite<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PMD-Parameter definieren das Link-Verlustbudget. Wenn ein Modul eine Sende-Leistung von \u20133 dBm bis +3 dBm und eine Empfangsempfindlichkeit von \u201314 dBm angibt, ergibt sich das nutzbare optische Budget aus diesen Werten.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Genauigkeit bei Tests und Konformit\u00e4t<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PMD definiert standardisierte Messpunkte (z.\u202fB. TP2, TP3), um sicherzustellen, dass optische Leistung, Jitter und Augendiagramme konsistent gemessen werden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Zuverl\u00e4ssigkeit \u00fcber die Zeit<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Module mit gr\u00f6\u00dferen PMD-Toleranzen vertragen Alterung, Temperaturschwankungen, Faserkontamination und Steckerverluste besser als Module, die nur den Mindestanforderungen entsprechen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Wichtige PMD-Parameter, die Sie bewerten m\u00fcssen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Jede PMD-Spezifikation umfasst mehrere kritische optische und elektrische Kenngr\u00f6\u00dfen. Ihr Verst\u00e4ndnis gew\u00e4hrleistet eine korrekte Modulauswahl.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Wellenl\u00e4nge (\u03bb) und spektrale Breite<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">H\u00e4ufig verwendete Werte umfassen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/850nm-optical-transceivers-for-short-reach-mmf-transmission\/\"><strong>850nm<\/strong><\/a> \u2014 kurze Reichweite, Multimode (SR)<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/1310nm-optical-module-applications-performance-comparison\/\"><strong>1310 nm<\/strong><\/a> \u2014 Einmodenfaser, mittlere Reichweite (LR)<\/p><\/li><li><p>Spezifische Bereiche f\u00fcr LX-, BX-, CWDM- und DWDM-Varianten<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Die spektrale Breite beeinflusst die Dispersion, insbesondere bei langen Verbindungen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Durchschnittliche Sendeleistung (Tx)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Gibt die minimale und maximale Ausgangsleistung an.<br\/>Zu niedrig \u2192 Verbindung erreicht m\u00f6glicherweise nicht den Empf\u00e4nger.<br\/>Zu hoch \u2192 kann Empf\u00e4nger \u00fcberlasten oder nichtlineare Effekte verursachen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Empfangsempfindlichkeit und \u00dcberlastung<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Empfindlichkeit:<\/strong> niedrigster Leistungspegel, bei dem der Empf\u00e4nger die BER-Anforderungen erf\u00fcllt<\/p><\/li><li><p><strong>\u00dcberlastung:<\/strong> maximale Eingangsleistung vor Auftreten von Signalverzerrungen<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese beiden Werte definieren das nutzbare <strong>optischen Leistungsbudgets<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Extinktionsverh\u00e4ltnis und R\u00fcckflussd\u00e4mpfung<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/extinction-ratio-importance-signal-quality-data-reliability\/\"><strong>Extinktionsverh\u00e4ltnis<\/strong><\/a> gew\u00e4hrleistet eine klare Unterscheidung zwischen logischem \u201c1\u201d und \u201c0\u201d.\u201d<\/p><\/li><li><p><strong>Optische R\u00fcckflussd\u00e4mpfung<\/strong> bestimmt die Toleranz gegen\u00fcber Reflexionen \u2013 entscheidend bei langen Einmodenstrecken.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Unterst\u00fctzte Fasertypen und Reichweite<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PMD-Tabellen geben an:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Reichweite f\u00fcr OM2\/OM3\/OM4-Multimodefasern<\/p><\/li><li><p>Reichweite f\u00fcr Einmodenfasern nach G.652\/G.655<\/p><\/li><li><p>Maximale unterst\u00fctzte L\u00e4nge gem\u00e4\u00df IEEE-Leistungs-Budgets<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f PMD bei der Auswahl optischer Transceiver<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bei der Auswahl optischer Module f\u00fcr <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-a-data-center\/\">Rechenzentren<\/a>, industrielle Netzwerke oder Telekommunikationsinfrastruktur \u2013 die Best\u00e4tigung der PMD-Konformit\u00e4t stellt sicher:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Echte IEEE-Interoperabilit\u00e4t<\/p><\/li><li><p>Korrekte Reichweite \u00fcber bestehende Glasfaser<\/p><\/li><li><p>Vorhersagbare D\u00e4mpfungsmargen<\/p><\/li><li><p>Robuste Leistung in temperaturbelasteten oder st\u00f6ranf\u00e4lligen Umgebungen<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Beispielsweise bedeutet die Auswahl zwischen <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475415.htm\"><strong>10GBASE-SR<\/strong><\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/475586.htm\"><strong>10GBASE-LR<\/strong><\/a>, und <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476054.htm\"><strong>10GBASE-ER<\/strong><\/a> im Wesentlichen die Wahl unterschiedlicher PMDs, die f\u00fcr 300\u202fm, 10\u202fkm oder 40\u202fkm optimiert sind.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b.webp\" alt=\"10GBASE-SR, 10GBASE-LR, and 10GBASE-E\" class=\"wp-image-3576\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/31aebd7127984c4e95dcb31cf479990b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Beispielhafte PMD-Zusammenfassungstabelle <\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Ersetzen Sie die Werte durch die exakten Parameter aus dem gew\u00e4hlten <\/em><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/file\/datasheet\/ls-sm3110-10c.pdf\"><em>SFP+-Modul-Datenblatt<\/em><\/a><em>.<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 220px;\"\/><col style=\"width: 214px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>PMD-Attribut<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>Typischer Wert<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Beschreibung<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Wellenl\u00e4nge<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>1310 nm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Einmoden-Langstreckenlaser<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Sende-Leistung (Min\/Max)<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u20133\u202fdBm \/ +3\u202fdBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Startleistungsbereich<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Empfindlichkeit des Empf\u00e4ngers<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u201314\u202fdBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mindestleistung f\u00fcr BER-Konformit\u00e4t<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Empf\u00e4nger\u00fcberlastung<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>+1\u202fdBm<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Maximal zul\u00e4ssige Eingangsleistung<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Reach<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>10km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>H\u00e4ngt von der Faserd\u00e4mpfung und den Splei\u00dfen ab<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"220\"><p>Extinktionsverh\u00e4ltnis<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"214\"><p>\u2265 3,5\u202fdB<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Lasermodulationsqualit\u00e4t<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f PMD-Pr\u00fcfung und Konformit\u00e4t<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Eine gut definierte PMD-Pr\u00fcfung gew\u00e4hrleistet zuverl\u00e4ssige Interoperabilit\u00e4t.<br\/>Zu den wesentlichen Messgr\u00f6\u00dfen geh\u00f6ren:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Optische Leistung am Sender und Empf\u00e4nger<\/p><\/li><li><p>Augenmasken-Konformit\u00e4t<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/jitter-in-optics-causes-effects-measurement-reduction\/\">Jitter<\/a> und Rauschabstand<\/p><\/li><li><p>Pr\u00fcfung an festgelegten Temperaturpunkten<\/p><\/li><li><p>Verifizierung der Empf\u00e4ngerempfindlichkeit unter belasteten Bedingungen<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Messungen entsprechen den IEEE-Konformit\u00e4tsverfahren.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Fehlerbehebung bei PMD-bedingten Ausf\u00e4llen<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Niedrige empfangene Leistung<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dcberpr\u00fcfen Sie die Sauberkeit der Steckverbinder, unerwartete Faserd\u00e4mpfung oder \u00fcberm\u00e4\u00dfiges Patching.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Link-Flaps bei langen Strecken<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pr\u00fcfen Sie Alterungseffekte der Sende-Leistung oder eine grenzwertige Empfindlichkeit \u2013 das optische Budget k\u00f6nnte zu knapp sein.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Multimode erreicht k\u00fcrzere Reichweiten als erwartet<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dcberpr\u00fcfen Sie die Kompatibilit\u00e4t mit OM3\/OM4; Bandbreitenbeschr\u00e4nkungen sind mediumspezifisch.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Fazit<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>physikalische Medium Dependent (PMD)<\/strong> Die Subschicht ist eines der grundlegenden Konzepte hinter der Interoperabilit\u00e4t der Ethernet-Physikalschicht. Durch die Spezifikation von optischer Wellenl\u00e4nge, Leistungsbereichen, Empfindlichkeit, Reichweite und Pr\u00fcfpunkten stellt die PMD sicher, dass Transceiver verschiedener Hersteller vorhersehbar auf derselben Glasfaserinfrastruktur arbeiten.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr Organisationen, die Netzwerke bereitstellen oder aktualisieren, ist das Verst\u00e4ndnis der PMD entscheidend, um die richtigen optischen Module auszuw\u00e4hlen und einen Link zu entwerfen, der zuverl\u00e4ssig, standardskonform und zukunftssicher ist.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Optische Transceiver von LINK-PP<\/strong><\/a> Enthalten klar definierte PMD-Spezifikationen und eignen sich daher hervorragend f\u00fcr robuste, standardskonforme Netzwerkdesigns.<\/p>","protected":false},"excerpt":{"rendered":"<p>Physical Medium Dependent (PMD) definiert die optischen und elektrischen Regeln eines PHY \u2013 Wellenl\u00e4nge, Leistung, Reichweite und Testpunkte. Verstehen Sie PMD-Spezifikationen und wie sie bei der Auswahl von Transceivern helfen.<\/p>","protected":false},"author":1,"featured_media":3577,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[24,26],"class_list":["post-3578","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3578","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=3578"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3578\/revisions"}],"predecessor-version":[{"id":10826,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3578\/revisions\/10826"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/3577"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=3578"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=3578"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=3578"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}