{"id":3573,"date":"2025-11-28T00:00:00","date_gmt":"2025-11-28T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/pcs-physical-coding-sublayer-ethernet-explained\/"},"modified":"2026-06-22T04:32:57","modified_gmt":"2026-06-22T04:32:57","slug":"pcs-physical-coding-sublayer-ethernet-explained","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/pcs-physical-coding-sublayer-ethernet-explained","title":{"rendered":"PCS (Physical Coding Sublayer): Eine vollst\u00e4ndige technische \u00dcbersicht"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/34f3d7140a36402fbca20e242d392164.webp\" alt=\"What Is the PCS in Ethernet?\" class=\"wp-image-3569\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/34f3d7140a36402fbca20e242d392164.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/34f3d7140a36402fbca20e242d392164-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/34f3d7140a36402fbca20e242d392164-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/34f3d7140a36402fbca20e242d392164-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/34f3d7140a36402fbca20e242d392164-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Physikalische Codierschicht (PCS)<\/strong> ist eine kritische Komponente des Ethernet <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-phy-physical-layer-basics-explained\/\"><strong>Physikalschicht (PHY)<\/strong><\/a>, sitzt zwischen der <strong>Reconciliation-Sublayer (RS)<\/strong> und die <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\"><strong>Physikalische Medium-Anbindung (PMA)<\/strong><\/a>. Ihre zentrale Aufgabe besteht darin, digitale Daten in ein Format umzuwandeln, das zuverl\u00e4ssig \u00fcber Kupfer- oder optische Medien \u00fcbertragen werden kann \u2013 selbst bei extrem hohen Geschwindigkeiten wie 10G, 25G, 40G, 100G und dar\u00fcber hinaus.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Der PCS hat sich durch zahlreiche <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">IEEE 802.3<\/a> \u00c4nderungen erheblich weiterentwickelt und unterst\u00fctzt zunehmend komplexere Codierungsschemata, um Synchronisation, Fehlererkennung und \u00dcbertragungseffizienz in modernen Netzwerken sicherzustellen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Was ist der PCS im Ethernet?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Physikalische Codierschicht<\/strong> definiert die f\u00fcr die Codierung, Decodierung, Ausrichtung und Steuerung erforderlichen Mechanismen, bevor Signale serialisiert und an die PMA gesendet werden. Er stellt sicher, dass Bin\u00e4rdaten aus h\u00f6heren Schichten korrekt f\u00fcr das elektrische oder optische Medium strukturiert sind.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vereinfacht ausgedr\u00fcckt bereitet der PCS die Daten f\u00fcr den Transport vor.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Wichtige Funktionen des PCS<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Leitungscodierung und Blockcodierung<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Der PCS implementiert je nach Ethernet-Generation spezifische Codierungsschemata:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>8B\/10B<\/strong> f\u00fcr fr\u00fches Gigabit-Ethernet<\/p><\/li><li><p><strong>64B\/66B<\/strong> f\u00fcr 10G\/25G\/40G\/100G-Ethernet<\/p><\/li><li><p><strong>256B\/257B<\/strong> f\u00fcr fortgeschrittene Architekturen wie 200G\/400G<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Codierungsbl\u00f6cke gew\u00e4hrleisten:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>ausreichende Signal\u00fcberg\u00e4nge f\u00fcr die Taktr\u00fcckgewinnung<\/p><\/li><li><p>ausgeglichene DC-Kennwerte<\/p><\/li><li><p>Einf\u00fcgung von Steuersymbolen<\/p><\/li><li><p>Fehlererkennungsfunktionen<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>64B\/66B<\/strong> ist das dominierende Schema in Hochgeschwindigkeitsoptik aufgrund geringer Overhead-Kosten und hoher Effizienz.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Synchronisation und Ausrichtungsmarker<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hochgeschwindigkeitsverbindungen erfordern, dass der Empf\u00e4nger Bit- und Frame-Ausrichtung beibeh\u00e4lt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Der PCS bietet:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Block-Synchronisation<\/p><\/li><li><p>Ausrichtungsmarker (insbesondere f\u00fcr Mehrkanalsysteme wie 40GBASE-R, 100GBASE-R)<\/p><\/li><li><p>Lane-Deskewing \u00fcber parallele optische Lanes hinweg<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ohne die Ausrichtungslogik des PCS k\u00f6nnte Ethernet mit mehreren Lanes keine deterministische und stabile Daten\u00fcbertragung unterst\u00fctzen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Fehlererkennung und Idle-Steuerung<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Die PCS-Schicht f\u00fcgt Struktur hinzu, die Folgendes erm\u00f6glicht:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Fehlerpr\u00fcfung mittels Block-G\u00fcltigkeit<\/p><\/li><li><p>Einf\u00fcgung von Idle-Zust\u00e4nden f\u00fcr das Link-Management<\/p><\/li><li><p>Geordnete Mengen f\u00fcr die Link-Verhandlung (z.\u202fB. \u201cLokaler Fehler\u201d, \u201cEntfernter Fehler\u201d)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Die PCS formatiert daher nicht nur Daten \u2013 sie unterst\u00fctzt auch die \u00dcberwachung der Verbindungsintegrit\u00e4t.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa1a7d937f634330be77e395e37df361.jpg\" alt=\"PCS (Physical Coding Sublayer)\" class=\"wp-image-3570\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa1a7d937f634330be77e395e37df361.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa1a7d937f634330be77e395e37df361-300x300.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa1a7d937f634330be77e395e37df361-150x150.jpg 150w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa1a7d937f634330be77e395e37df361-768x768.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/aa1a7d937f634330be77e395e37df361-12x12.jpg 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f PCS vs. PMA vs. PMD \u2013 So arbeiten sie zusammen<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >PCS \u2192 PMA \u2192 PMD \u2013 \u00dcbersicht<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 355px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"355\"><p>Schicht<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Funktion<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"355\"><p><strong>PCS (Physical Coding Sublayer)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Codierung, Ausrichtung, Kanalverteilung<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"355\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/pma-physical-medium-attachment-ethernet-explained\/\"><strong>PMA (Physikalische Medienanbindung)<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Seriellisierung\/Deserialisierung, St\u00f6rungscodierung (Scrambling)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"355\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-physical-medium-dependent-pmd\/\"><strong>PMD (Medienabh\u00e4ngige physikalische Schicht)<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Definiert optische\/elektrische \u00dcbertragungsmedien, Wellenl\u00e4ngen und Modulationsverfahren<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Die PCS bereitet digitale Bl\u00f6cke vor.<br\/>Die PMA serialisiert die Bits.<br\/>Die PMD interagiert mit dem physikalischen \u00dcbertragungsmedium, z.\u202fB. Glasfaser, Kupfer oder Backplane.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Warum die PCS in modernen optischen Transceivern wichtig ist<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hochgeschwindigkeitsoptikmodule \u2013 wie z.\u202fB. <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476909.htm\"><strong>SFP+<\/strong><\/a><strong>, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491606.htm\"><strong>SFP28<\/strong><\/a><strong>, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\"><strong>QSFP+<\/strong><\/a><strong>, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488452.htm\"><strong>QSFP28<\/strong><\/a><strong>, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\"><strong>QSFP56<\/strong><\/a>\u2013 setzen auf PCS-Funktionen, um Interoperabilit\u00e4t zwischen Switches, Routern und Data-Center-Ausr\u00fcstung zu gew\u00e4hrleisten.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6af2399d28934f05bddfa8639d9fd6d5.webp\" alt=\"SFP+, SFP28, QSFP+, QSFP28, QSFP56 optical modules\" class=\"wp-image-3571\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6af2399d28934f05bddfa8639d9fd6d5.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6af2399d28934f05bddfa8639d9fd6d5-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6af2399d28934f05bddfa8639d9fd6d5-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6af2399d28934f05bddfa8639d9fd6d5-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/6af2399d28934f05bddfa8639d9fd6d5-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Wichtige Gr\u00fcnde, warum die PCS in optischen Transceivern unverzichtbar ist:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Gew\u00e4hrleistung einer niedrigen <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-what-is-bit-error-rate\/\">BER (Bitfehlerrate)<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Effiziente Blockcodierung und -ausrichtung reduzieren \u00dcbertragungsfehler und erh\u00f6hen die Zuverl\u00e4ssigkeit der Verbindung.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Unterst\u00fctzung mehrkanaliger Architekturen<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">40GBASE-R und 100GBASE-R st\u00fctzen sich stark auf PCS-Kanal-Streifung (lane striping) und Deskew-Logik.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Erm\u00f6glichung h\u00f6herer Anschlussdichte<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Codierungseffizienz (z.\u202fB. 64B\/66B) minimiert Overhead und erm\u00f6glicht mehr Bandbreite pro Kanal.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Verwandte LINK-PP-Produkte<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP bietet eine breite Palette an <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">Optische Transceiver<\/a> die mit IEEE-PCS-basierten Ethernet-Standards kompatibel sind, darunter:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\"><strong>10G-SFP+-Module<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\"><strong>25G-SFP28-Transceiver<\/strong><\/a><\/p><\/li><li><p><strong>40G\/100G <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\"><strong>QSFP+<\/strong><\/a><strong> \/ <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/488452.htm\"><strong>QSFP28-Module<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/476909.htm\"><strong>Industrielle optische Transceiver<\/strong><\/a><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Module sind f\u00fcr Kompatibilit\u00e4t, niedrige Bitfehlerrate (BER) und stabile Funktion \u00fcber PCS-basierte Ethernet-PHYs konzipiert.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Die PCS in verschiedenen Ethernet-Standards<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 PCS im 10-Gigabit-Ethernet (10GBASE-R)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Uses <strong>64B\/66B<\/strong> Codierung<\/p><\/li><li><p>Definiert Block-Synchronisation (block lock) und Markerdetektion<\/p><\/li><li><p>Optimiert f\u00fcr Langstrecken-Optik\u00fcbertragung<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 PCS im 25-Gigabit-Ethernet (25GBASE-R)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Beh\u00e4lt 64B\/66B bei<\/p><\/li><li><p>F\u00fchrt eine verbesserte FEC-Integration (Forward Error Correction) ein<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 PCS im 40G\/100G-Ethernet (40GBASE-R \/ 100GBASE-R)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>F\u00fchrt Kanalmultiplexierung mit Ausrichtungsmarkern ein<\/p><\/li><li><p>Von entscheidender Bedeutung f\u00fcr die Stabilit\u00e4t \u00fcber parallele Glasfaserverbindungen<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 PCS in Architekturen \u00fcber 100\u202fGbit\/s hinaus<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE-802.3bs- und 802.3cd-Erweiterungen f\u00fchren ein:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Gr\u00f6\u00dfere Blockgr\u00f6\u00dfen<\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">PAM4-Modulation<\/a> (wird auf PMA\/PMD-Ebene verarbeitet, jedoch in Abstimmung mit der PCS)<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Anwendungen, in denen die PCS eine kritische Rolle spielt<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Rechenzentren<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hochdurchsatz-Spine-Leaf-Netzwerke setzen auf die PCS f\u00fcr verlustfreie Kommunikation zwischen Switches.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Carrier- und Metro-Ethernet<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Die PCS tr\u00e4gt dazu bei, die Signalintegrit\u00e4t \u00fcber optische Langstreckenverbindungen zu bewahren.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Industrieller Ethernet<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Eine stabile PCS-Codierung ist entscheidend f\u00fcr deterministischen Datenverkehr in rauen Umgebungen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u27a1\ufe0f Fazit<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Physikalische Codierschicht (PCS)<\/strong> ist ein grundlegendes Element der Ethernet-PHY-Architektur und erm\u00f6glicht eine zuverl\u00e4ssige Datenkodierung, Synchronisation und Ausrichtung sowohl bei Kupfer- als auch bei optischen \u00dcbertragungen. Mit steigenden Datenraten bis hin zu 100 G, 200 G und 400 G entwickelt sich die PCS kontinuierlich weiter und unterst\u00fctzt fortschrittliche Kodierungsverfahren sowie Mehrkanal-Designs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr Systemintegratoren, Rechenzentrumsingenieure und OEMs hilft das Verst\u00e4ndnis der PCS dabei, die richtige Auswahl von Transceivern, PHY-Komponenten und Netzwerkger\u00e4ten sicherzustellen \u2013 was letztendlich die Link-Leistung, Interoperabilit\u00e4t und Gesamtzuverl\u00e4ssigkeit des Netzwerks verbessert.<\/p>","protected":false},"excerpt":{"rendered":"<p>Erfahren Sie, was die PCS (Physical Coding Sublayer) ist, wie sie zuverl\u00e4ssiger Ethernet-\u00dcbertragung erm\u00f6glicht und warum sie f\u00fcr Hochgeschwindigkeitsoptiktransceiver und Netzwerkdesign wichtig ist.<\/p>","protected":false},"author":1,"featured_media":3572,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[24,26],"class_list":["post-3573","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3573","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=3573"}],"version-history":[{"count":5,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3573\/revisions"}],"predecessor-version":[{"id":10822,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3573\/revisions\/10822"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/3572"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=3573"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=3573"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=3573"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}