{"id":3480,"date":"2025-12-03T13:59:00","date_gmt":"2025-12-03T13:59:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/high-speed-backplane-channel-ethernet-guide\/"},"modified":"2026-06-22T04:24:17","modified_gmt":"2026-06-22T04:24:17","slug":"high-speed-backplane-channel-ethernet-guide","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/high-speed-backplane-channel-ethernet-guide","title":{"rendered":"Ein umfassender technischer Leitfaden f\u00fcr Hochgeschwindigkeits-Backplane-Systeme"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/43a4b11835b9491e82e0d177ffe3825d.webp\" alt=\"What Is a Backplane?\" class=\"wp-image-3475\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/43a4b11835b9491e82e0d177ffe3825d.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/43a4b11835b9491e82e0d177ffe3825d-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/43a4b11835b9491e82e0d177ffe3825d-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/43a4b11835b9491e82e0d177ffe3825d-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/43a4b11835b9491e82e0d177ffe3825d-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Was ist eine Backplane?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>backplane<\/strong> ist eine gro\u00dfe <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pcb-printed-circuit-board\/\">Leiterplatte (PCB)<\/a> die <strong>Hochgeschwindigkeits-Elektrik-Verbindungen bereitstellt<\/strong> et <strong>Stromverteilung<\/strong> zwischen mehreren Steckkarten innerhalb eines Geh\u00e4uses. Im Gegensatz zu einer Hauptplatine enth\u00e4lt eine Backplane typischerweise passive Komponenten wie hochdichte Steckverbinder und Leiterplattenleitungen mit kontrollierter Impedanz.<br\/>Backplanes werden weit verbreitet eingesetzt in <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-a-network-switch\/\"><strong>Switches<\/strong><\/a><strong>, <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-a-router-key-functions-types\/\"><strong>Router<\/strong><\/a><strong>, Telekommunikationsausr\u00fcstung, Blade-Servern, Speichergeh\u00e4usen und industriellen Steuerungssystemen<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Um diese Plattformen zu unterst\u00fctzen, bietet LINK-PP Hochleistungs- <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\"><strong>Integrierte RJ45-Steckverbinder<\/strong><\/a>, die in backplanebasierte Systeme integriert werden k\u00f6nnen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Warum Backplanes in Hochgeschwindigkeitssystemen entscheidend sind<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Moderne Systeme nutzen Backplanes, um Bandbreitenstarke, latenzarme Kommunikation zwischen internen Modulen zu gew\u00e4hrleisten.<br\/>Typische Anwendungen umfassen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Verbindung zwischen Line-Card und Switch-Fabric<\/strong><\/p><\/li><li><p><strong>Midplane-Interconnect f\u00fcr Blade-Server<\/strong><\/p><\/li><li><p><strong>Hot-swap <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-io-modules-in-automation-and-networking\/\"><strong>I\/O-Modul<\/strong><\/a><strong> Verbindungen<\/strong><\/p><\/li><li><p><strong>40G\/100G-Ethernet-\u00dcbertragung innerhalb des Geh\u00e4uses<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Backplane-Kan\u00e4le erm\u00f6glichen es Systemen, skalierbar zu sein, w\u00e4hrend Zuverl\u00e4ssigkeit und Signalintegrit\u00e4t erhalten bleiben.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Erkl\u00e4rung von Backplane-Kan\u00e4len<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>Backplane-Kanal<\/strong> ist der vollst\u00e4ndige elektrische Pfad, der folgende Komponenten umfasst:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Leiterplatten-\u00dcbertragungsleitungen<\/p><\/li><li><p>Durchkontaktierungen (Vias) und Back-Drilling<\/p><\/li><li><p>Hochgeschwindigkeits-Board-to-Board-Steckverbinder<\/p><\/li><li><p>Anschlussfl\u00e4chen\/-geometrien der steckbaren Module<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Kan\u00e4le unterst\u00fctzen Hochgeschwindigkeits- <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\">SERDES<\/a> Signale wie z.\u202fB. <strong>10G-, 25G-, 50G- und 100G-Ethernet-Lanes<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Backplane-Kan\u00e4le stehen vor besonderen Herausforderungen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>High <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/insertion-loss-impact-on-rj45-magjack\/\">Einf\u00fcgungsd\u00e4mpfung<\/a><\/p><\/li><li><p>\u00dcbersprechen (Crosstalk) zwischen parallelen Leitungen<\/p><\/li><li><p>Impedanz-Unstetigkeiten<\/p><\/li><li><p>Parasit\u00e4rwiderst\u00e4nde des Steckverbinders<\/p><\/li><li><p>Kurze Distanzen bei gleichzeitig hoher D\u00e4mpfung<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Daher m\u00fcssen Standards und Konstruktionsrichtlinien strikt eingehalten werden.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d0321c4d4bad46629f867bf1e0560895.jpg\" alt=\"Backplane Channels\" class=\"wp-image-3476\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d0321c4d4bad46629f867bf1e0560895.jpg 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d0321c4d4bad46629f867bf1e0560895-300x300.jpg 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d0321c4d4bad46629f867bf1e0560895-150x150.jpg 150w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d0321c4d4bad46629f867bf1e0560895-768x768.jpg 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/d0321c4d4bad46629f867bf1e0560895-12x12.jpg 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Backplane-Standards (PICMG, VITA, IEEE)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Backplane-Systeme folgen h\u00e4ufig branchen\u00fcblichen Standards, um Kompatibilit\u00e4t und optimale Leistung sicherzustellen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >PICMG-Backplanes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Verwendet in <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/industrial-pcs-ipcs-rugged-computing-iiot-edge-control\/\">Industrie-PCs<\/a> und eingebettete Systeme, z.\u202fB.:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>PICMG 1.3 f\u00fcr PCI Express<\/p><\/li><li><p>Compact-PCI-Systeme<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >VITA \/ VPX \/ OpenVPX<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Robuste milit\u00e4rische und telekommunikative Plattformen verwenden VPX-Backplanes mit hochdichten Steckverbindern und definierten Fabric-Topologien.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >IEEE-Backplane-Ethernet-Standards<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Backplane-Ethernet ist im Rahmen der <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\">IEEE 802.3-Standards<\/a>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>10GBASE-KR<\/strong> \u2014 10G-Ethernet \u00fcber Backplane<\/p><\/li><li><p><strong>40GBASE-KR4<\/strong> \u2014 4\u00d710G-Lanes<\/p><\/li><li><p><strong>100GBASE-KP4<\/strong> \u2014 <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\">PAM4-Modulation<\/a> mit FEC<\/p><\/li><li><p><strong>IEEE 802.3bj<\/strong> \u2014 definiert elektrische Parameter f\u00fcr 100-G-Backplane-\/Kupferkan\u00e4le<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Standards definieren die Kanaleintragungsd\u00e4mpfung, die Entzerrung und die Verbindungsanlernverfahren.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5518d06d98dc47fa81085cea014032a2.webp\" alt=\"Backplane PCB\" class=\"wp-image-3477\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5518d06d98dc47fa81085cea014032a2.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5518d06d98dc47fa81085cea014032a2-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5518d06d98dc47fa81085cea014032a2-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5518d06d98dc47fa81085cea014032a2-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/5518d06d98dc47fa81085cea014032a2-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Typen von Backplane-Architekturen<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Passive Backplanes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Enthalten haupts\u00e4chlich Steckverbinder und Leiterbahnen.<br\/>Vorteile: niedrige Kosten, hohe Zuverl\u00e4ssigkeit, lange Lebensdauer.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Aktive Backplanes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Enthalten Switches, Retimer, Taktschaltkreise oder Signalkonditionierungsbausteine.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Midplanes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Eine Backplane, die sich in der Mitte des Geh\u00e4uses befindet und Verbindungen von Modulen an Front- und R\u00fcckseite erm\u00f6glicht (h\u00e4ufig in Blade-Servern).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Herausforderungen beim Design hochgeschwindigkeitsf\u00e4higer Backplanes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Signalintegrit\u00e4tsfaktoren (SI)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/insertion-loss-impact-on-rj45-magjack\/\"><strong>Einf\u00fcged\u00e4mpfung (IL)<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/rj45-connector-in-network-switch\/\"><strong>R\u00fcckflussd\u00e4mpfung (RL)<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/crosstalk-definition-causes-types-effects\/\"><strong>\u00dcbersprechen<\/strong><\/a><strong> (NEXT &amp; FEXT)<\/strong><\/p><\/li><li><p><strong>Kanal-Skew und Jitter-Marge<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Backplane-Designer m\u00fcssen optimieren: <strong>Schichtaufbau, Dielektrikum-Materialien, Kupfer-Rauheit, Via-Design, Steckverbinder-Footprint<\/strong>, und <strong>Routing-Strategie<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Hochgeschwindigkeits-LAN-Magnetikkomponenten f\u00fcr Backplane-Systeme<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hochgeschwindigkeitssysteme erfordern zudem zuverl\u00e4ssige I\/O-Module.<br\/>LINK-PP bietet ein breites Portfolio an <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-17492-integrated-rj45-connector.htm\"><strong>RJ45-Steckverbinder mit integrierter Magnetik (ICMs)<\/strong><\/a> werden in backplanebasierten Plattformen (Switches, Server, Telekommunikationsger\u00e4te) eingesetzt.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ffb06ac9e60d4e4e8ae2e91a6997ba9b.webp\" alt=\"RJ45 connectors with integrated magnetics\" class=\"wp-image-3478\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ffb06ac9e60d4e4e8ae2e91a6997ba9b.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ffb06ac9e60d4e4e8ae2e91a6997ba9b-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ffb06ac9e60d4e4e8ae2e91a6997ba9b-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ffb06ac9e60d4e4e8ae2e91a6997ba9b-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/ffb06ac9e60d4e4e8ae2e91a6997ba9b-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Geeignet f\u00fcr:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Netzwerkmodule mit Backplane-Anschluss<\/p><\/li><li><p>Switch-Management-Boards<\/p><\/li><li><p>Fabric-Control-Karten<\/p><\/li><li><p>Eingebettete industrielle Plattformen<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Steckverbinder erf\u00fcllen die elektrischen Anforderungen der IEEE-802.3-Norm und bieten hervorragende EMI- und SI-Leistung.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Einsatzgebiete von Backplanes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Rechenzentren und Unternehmensnetzwerke<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Switches und Router nutzen Backplanes, um Linecards mit Geschwindigkeiten von 40 G\/100 G miteinander zu verbinden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Telekommunikation (5G, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-olt-and-its-importance-in-fiber-optic-networks\/\">OLT<\/a>\/BBU)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hochdichte-Chassis setzen auf Backplanes, um die aggregierte Durchsatzkapazit\u00e4t zwischen Steuer-, Stromversorgungs- und Signal-Einheiten zu \u00fcbertragen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Industrielle und milit\u00e4rische Systeme<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Robuste VPX-Backplanes unterst\u00fctzen missionkritische Anwendungen mit Sto\u00df- und vibrationsfestem Betrieb.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Speichersysteme<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">SAS\/SATA\/<a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-nvme-non-volatile-memory-express\/\">NVMe<\/a> Backplanes bieten Hot-Swap-Laufwerksanschl\u00fcsse sowie Geh\u00e4use-Management.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Backplane vs. Midplane vs. Kabelbaugruppen<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >R\u00fcckwandplatine<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Interne Leiterplatte<\/p><\/li><li><p>Kurzstrecken, hohe Bandbreite<\/p><\/li><li><p>Mehrsteckplatz-Design<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Midplane<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Trennt Front- und R\u00fcckmodule<\/p><\/li><li><p>Reduziert die mechanische Komplexit\u00e4t<\/p><\/li><li><p>Wird in Blade-Servern eingesetzt<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Kabelbaugruppen (<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26454-dac-aoc-aec-cables.htm\">DAC\/AOC<\/a>)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Flexibel<\/p><\/li><li><p>Externe Verkabelung<\/p><\/li><li><p>Geringere Dichte, aber gr\u00f6\u00dfere Reichweiten<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Backplanes sind das R\u00fcckgrat leistungsstarker Systeme und erm\u00f6glichen <strong>zuverl\u00e4ssige, hochgeschwindigkeitsf\u00e4hige und skalierbare interne Konnektivit\u00e4t<\/strong> f\u00fcr moderne Ethernet-, Telekommunikations-, Industrie- und Embedded-Plattformen.<br\/>Durch die Kombination einer robusten Backplane-Architektur mit hochwertigen Komponenten \u2013 wie etwa <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.rj45-modularjack.com\/supplier-26966-magnetic-rj45-jack\"><strong>LINK-PP-RJ45-ICMs<\/strong><\/a><strong> <\/strong>\u2013 k\u00f6nnen Systemdesigner hervorragende Signalintegrit\u00e4t, reduzierte elektromagnetische St\u00f6rungen (EMI) und langfristige Zuverl\u00e4ssigkeit in anspruchsvollen Anwendungen erreichen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Siehe auch (verwandte technische Ressourcen)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Um weitere hochwertige Netzwerk- und Hardwarekonzepte zu erkunden, besuchen Sie diese verwandten technischen Ressourcen von LINK-PP:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Grundlegende Elektronik- und Hardwarekonzepte<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pcb-printed-circuit-board\/\"><strong>Was ist eine Leiterplatte (PCB, Printed Circuit Board)?<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\"><strong>Verst\u00e4ndnis von SERDES-Schnittstellen und Hochgeschwindigkeitsdaten\u00fcbertragung<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-pam4-four-level-pulse-amplitude-modulation-basics\/\"><strong>Was ist PAM4? Grundlagen der vierstufigen Pulsspannungsmodulation<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/crosstalk-definition-causes-types-effects\/\"><strong>\u00dcbersprechen (Crosstalk): Definition, Ursachen, Arten und Auswirkungen<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/insertion-loss-impact-on-rj45-magjack\/\"><strong>Einf\u00fcgungsd\u00e4mpfung und ihre Auswirkung auf RJ45-\/MagJack\u00ae-Konnektivit\u00e4t<\/strong><\/a><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Netzwerkger\u00e4te und -systeme<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-a-router-key-functions-types\/\"><strong>Was ist ein Router? Wichtige Funktionen und Typen im \u00dcberblick<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-a-network-switch\/\"><strong>Was ist ein Netzwerk-Switch? Ein umfassender technischer \u00dcberblick<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/rj45-connector-in-network-switch\/\"><strong>RJ45-Steckverbinder in Netzwerk-Switches<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/understanding-io-modules-in-automation-and-networking\/\"><strong>Verst\u00e4ndnis von I\/O-Modulen in Automatisierung und Netzwerktechnik<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-olt-and-its-importance-in-fiber-optic-networks\/\"><strong>Was ist ein OLT und welche Rolle spielt er in Glasfasernetzwerken?<\/strong><\/a><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Industrielle und Hochleistungsrechnersysteme<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/industrial-pcs-ipcs-rugged-computing-iiot-edge-control\/\"><strong>Industrie-PCs (IPCs) f\u00fcr robuste Rechenanwendungen und das industrielle Internet der Dinge (IIoT)<\/strong><\/a><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/what-is-nvme-non-volatile-memory-express\/\"><strong>Was ist NVMe (Non-Volatile Memory Express)?<\/strong><\/a><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Ethernet-Standards und Hochgeschwindigkeitsschnittstellen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/ieee-802-3-ethernet-standard-explained\/\"><strong>Erl\u00e4uterung der IEEE-802.3-Ethernet-Standards<\/strong><\/a><\/p><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Erfahren Sie, was ein Backplane ist, wie Backplane-Kan\u00e4le Hochgeschwindigkeits-40G\/100G-Ethernet unterst\u00fctzen, welche wichtigen Standards gelten und welche Designherausforderungen bestehen. Lernen Sie, wie LINK-PP-RJ45-Steckverbinder die Backplane-Leistung verbessern.<\/p>","protected":false},"author":1,"featured_media":3479,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[19,22,24],"class_list":["post-3480","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-aoc-dac-cables","tag-integrated-rj45-connectors","tag-link-pp"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3480","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=3480"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3480\/revisions"}],"predecessor-version":[{"id":10806,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3480\/revisions\/10806"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/3479"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=3480"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=3480"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=3480"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}