{"id":3347,"date":"2025-12-08T00:00:00","date_gmt":"2025-12-08T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/xlaui-vs-xlppi-40g-electrical-interface-comparison\/"},"modified":"2026-06-22T04:14:52","modified_gmt":"2026-06-22T04:14:52","slug":"xlaui-vs-xlppi-40g-electrical-interface-comparison","status":"publish","type":"post","link":"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/xlaui-vs-xlppi-40g-electrical-interface-comparison","title":{"rendered":"XLPPI im Vergleich zu XLAUI erkl\u00e4rt: Elektrische Schnittstellen f\u00fcr QSFP-Module"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2e2d466bb30d4bea9b595f0115996a62.webp\" alt=\"XLPPI vs. XLAUI\" class=\"wp-image-3340\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2e2d466bb30d4bea9b595f0115996a62.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2e2d466bb30d4bea9b595f0115996a62-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2e2d466bb30d4bea9b595f0115996a62-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2e2d466bb30d4bea9b595f0115996a62-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/2e2d466bb30d4bea9b595f0115996a62-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In Hochgeschwindigkeits-Ethernet-Systemen bestimmen elektrische Schnittstellen, wie Daten zwischen einem Host-Ger\u00e4t und einem optischen Transceiver flie\u00dfen. Zwei weit verbreitete Schnittstellen in 40G- und 100G-Netzwerkarchitekturen sind<br> <strong>XLPPI<\/strong> et <strong>XLAUI<\/strong>. Obwohl sie oberfl\u00e4chlich betrachtet \u00e4hnlich erscheinen \u2013 beide definieren mehrkanalige elektrische Signalisierung \u2013 erf\u00fcllen sie<br> <strong>unterschiedliche Zwecke<br><\/strong>, stammen von<br> <strong>verschiedenen Standardisierungsgremien<br><\/strong>, und unterst\u00fctzen<br> <strong>unterschiedliche Leistungsgenerationen.<br><\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dieser Artikel bietet einen strukturierten, autoritativen Vergleich von<br> <strong>XLPPI vs. XLAUI<br><\/strong>, um zu verdeutlichen, wie jede Schnittstelle in moderne optische Modul-\u00d6kosysteme passt, insbesondere bei<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">QSFP+<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491591.htm\">QSFP28<\/a>, und <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">QSFP56<\/a> Modulen, die weit verbreitet in Rechenzentren eingesetzt werden.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Die Grundlage: IEEE 802.3ba und die 40G-Architektur<br><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"721\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3426d25714404c1993f09e9f21abe054.webp\" alt=\"IEEE 802.3ba standard\" class=\"wp-image-3341\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3426d25714404c1993f09e9f21abe054.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3426d25714404c1993f09e9f21abe054-300x180.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3426d25714404c1993f09e9f21abe054-1024x615.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3426d25714404c1993f09e9f21abe054-768x461.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/3426d25714404c1993f09e9f21abe054-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bevor wir uns den Unterschieden zuwenden, m\u00fcssen wir die gemeinsame Basis verstehen. Sowohl XLAUI als auch XLPPI sind im Rahmen der<br> <a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-ieee-802-3ba-standard\/\"><strong>IEEE 802.3ba<\/strong> Standard-<\/a> f\u00fcr 40-Gigabit-Ethernet definiert.<br>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Das \u201cXL\u201d in beiden Akronymen steht f\u00fcr die r\u00f6mische Zahl f\u00fcr 40. Beide Schnittstellen nutzen eine<br> <strong>4-Kanal-Parallelarchitektur<br><\/strong>, wobei jeder Kanal mit<br> <strong>10,3125 Gbit\/s<\/strong>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Gesamtbandbreite:<br><\/strong> 41,25 Gbps (einschlie\u00dflich 64b\/66b-Codierungs-Overhead).<br>.<\/p><\/li><li><p><strong>Effektive Datendatenrate:<br><\/strong> 40 Gbps.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Allerdings unterscheiden sie sich hinsichtlich ihrer Position innerhalb der OSI-Physischen-Schicht-(PHY)-Hierarchie.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Was ist XLAUI? (40G Attachment Unit Interface)<br><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb.webp\" alt=\"What Is XLAUI? (40G Attachment Unit Interface)\" class=\"wp-image-3342\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/xlaui-10-lane-attachment-unit-interface-ethernet-explained\/\"><strong>XLAUI (40G Attachment Unit Interface)<br><\/strong><\/a> ist eine von der IEEE definierte elektrische Schnittstelle, die in<br> <strong>IEEE 802.3ba<\/strong> for <strong>40-Gigabit-Ethernet (40GbE)<\/strong>. eingef\u00fchrt wurde. Sie arbeitet mit:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Wichtige Merkmale von XLPPI<\/strong><\/p><\/li><li><p><strong>10,3125 Gbps pro Kanal<br><\/strong><\/p><\/li><li><p><strong>64B\/66B-Leitungscodierung<br><\/strong><\/p><\/li><li><p><strong>NRZ-Signalisierung<br><\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Zweck von XLAUI im 40G-Ethernet<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">XLAUI fungiert als interne elektrische Verbindung zwischen:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>MAC \u21c6 PHY<br><\/strong><\/p><\/li><li><p><strong>MAC \u21c6 PMA\/PMD<br><\/strong><\/p><\/li><li><p><strong>PHY \u21c6 internem optischem Motor (bei Plattformen mit fest eingebauter Optik)<br><\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Sie wird nicht direkt an der Steckverbinderschnittstelle f\u00fcr steckbare Module verwendet. Stattdessen ist XLAUI Teil des internen Signalpfads von Switches, Routern und Netzwerkkarten.<br>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Einsatzgebiete von XLAUI<br><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">XLAUI ist vor allem mit folgenden Technologien verbunden:<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482754.htm\"><strong>40GBASE-SR4<\/strong><\/a><strong> (MPO-12-Faser)<br><\/strong><\/p><\/li><li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482754.htm\"><strong>40GBASE-LR4<\/strong><\/a><strong> (4\u00d710G \u03bb WDM)<br><\/strong><\/p><\/li><li><p><strong>40GBASE-CR4 (DAC-Kabel)<br><\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Obwohl diese Module vier 10G-Kan\u00e4le nutzen, wird die XLAUI-Schnittstelle typischerweise<br> <strong>innerhalb des Hosts<br><\/strong>, implementiert, nicht am QSFP+-Anschluss.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >Was ist XLPPI? (Extended Low-Power\/Low-Voltage Parallel Interface)<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9cd1ef29cc8048e184bfce71116e12dd.webp\" alt=\"What Is XLPPI? \" class=\"wp-image-3343\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9cd1ef29cc8048e184bfce71116e12dd.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9cd1ef29cc8048e184bfce71116e12dd-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9cd1ef29cc8048e184bfce71116e12dd-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9cd1ef29cc8048e184bfce71116e12dd-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9cd1ef29cc8048e184bfce71116e12dd-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/xlppi-electrical-interface-in-40g-qsfp-plus-modules-explained\/\"><strong>XLPPI <\/strong><\/a><strong>(Erweiterte Low-Power\/Low-Voltage-Parallel-Schnittstelle)<\/strong> ist eine von der MSA definierte elektrische Schnittstelle, die zwischen folgenden Komponenten verwendet wird:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Host-PHY\/ASIC \u21c6 steckbare optische Module der QSFP-Familie<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Im Gegensatz zu XLAUI (beschr\u00e4nkt auf 40 G), umfasst XLPPI <strong>mehrere Ethernet-Generationen<\/strong> und mehrere QSFP-Formfaktoren.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Unterst\u00fctzte Geschwindigkeiten und Modulation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">XLPPI unterst\u00fctzt:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"width: 111px;\"\/><col style=\"width: 152px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Ethernet-Generation<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Modultyp<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"111\"><p>Lanes<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"152\"><p>Lane-Rate<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Modulation<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>40G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482754.htm\">QSFP+<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"111\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"152\"><p>10G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>100G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491587.htm\">QSFP28<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"111\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"152\"><p>25G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>200G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">QSFP56<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"111\"><p>4<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"152\"><p>50G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PAM4<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>400G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\">QSFP-DD<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"111\"><p>8<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"152\"><p>50G PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PAM4<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>800G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP-DD800<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"111\"><p>8<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"152\"><p>100 G PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PAM4<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Zweck von XLPPI<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">XLPPI gew\u00e4hrleistet:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Niederspannungs-, niedrigstromoptimierte parallele Signal\u00fcbertragung<\/p><\/li><li><p>Zuverl\u00e4ssige hochgeschwindigkeitsf\u00e4hige elektrische Verbindung zwischen Host und Modul<\/p><\/li><li><p>Kompatibilit\u00e4t \u00fcber alle QSFP-Generationen hinweg<\/p><\/li><li><p>Stabile Funktion \u00fcber kurze Leiterplattenleitungen mit strengen Signalintegrit\u00e4tsanforderungen (SI)<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Damit ist XLPPI die dominierende elektrische Schnittstelle hinter modernen steckbaren Optikmodulen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >XLPPI vs. XLAUI \u2013 Wichtige Unterschiede<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9302b83d121c4c5c9a0967b7511658c7.webp\" alt=\"XLPPI vs. XLAUI\" class=\"wp-image-3344\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9302b83d121c4c5c9a0967b7511658c7.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9302b83d121c4c5c9a0967b7511658c7-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9302b83d121c4c5c9a0967b7511658c7-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9302b83d121c4c5c9a0967b7511658c7-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/9302b83d121c4c5c9a0967b7511658c7-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Die beiden Schnittstellen arbeiten in unterschiedlichen Bereichen der Ethernet-Architektur und verfolgen unterschiedliche Designziele.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Unterschiedliche Standardisierungsgremien<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 168px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"168\"><p>Schnittstelle<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Definiert von<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Prim\u00e4rer Anwendungsbereich<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"168\"><p><strong>XLAUI<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-ieee-802-3ba-standard\/\">IEEE 802.3ba<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interne Schnittstelle zwischen MAC \u21c6 PHY<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"168\"><p><strong>XLPPI<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP\/QSFP-DD-MSA<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Schnittstelle zwischen Host \u21c6 steckbarem optischem Modul<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">XLPPI ist eng an die QSFP-Familie gebunden, w\u00e4hrend XLAUI an die internen logischen Schichten des Ethernet gebunden ist.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Unterschiedliche Anwendungsschichten<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Schicht<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/xlaui-10-lane-attachment-unit-interface-ethernet-explained\/\">XLAUI<\/a><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/maximizing-network-performance-with-xlppi-electrical-interface\/\">XLPPI<\/a><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Schnittstellenposition<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Innerhalb von Switch\/Router<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Am Modulstecker<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Nutzer<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MAC, PHY, PMA\/PMD<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>ASIC\/PHY \u21c6 QSFP-Modul<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Exposition gegen\u00fcber Hardware-Ingenieuren<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Internes Siliziumdesign<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Leiterplattendesign f\u00fcr steckbare Transceiver<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Einsatz bei steckbaren Optikmodulen<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Indirekt<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Direkt<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Unterschiedlich unterst\u00fctzte Geschwindigkeiten<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">XLAUI ist festgelegt auf:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>4 \u00d7 10,3125 Gbps (40 G)<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">XLPPI skaliert von <strong>40 G \u2192 800 G<\/strong>, je nach Modulformfaktor und SerDes-Generation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Signaltechnologien<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 211px;\"\/><col style=\"width: 221px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"211\"><p>Funktion<\/p><\/th><th colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>XLAUI<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>XLPPI<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"211\"><p>Signalausbreitung<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/what-is-the-difference-between-nrz-and-pam4\/\">NRZ + PAM4<\/a><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"211\"><p>Spannung<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>Standard<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Niederspannungs-\/stromoptimiert<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"211\"><p>SI-Optimierung<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>Veraltet<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fortgeschritten, speziell f\u00fcr QSFP<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"211\"><p>Future-proofing<\/p><\/td><td colspan=\"1\" rowspan=\"1\" colwidth=\"221\"><p>Nein (nur 40 G)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ja (40 G\u2013800 G)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >Warum moderne QSFP-Module XLPPI statt XLAUI verwenden<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4d95a67d409e804dd80bb6e79bbd.webp\" alt=\"QSFP Modules\" class=\"wp-image-3345\" srcset=\"https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4d95a67d409e804dd80bb6e79bbd.webp 1200w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4d95a67d409e804dd80bb6e79bbd-300x178.webp 300w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4d95a67d409e804dd80bb6e79bbd-1024x608.webp 1024w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4d95a67d409e804dd80bb6e79bbd-768x456.webp 768w, https:\/\/resourceslp.szlogic.cn\/wp-content\/uploads\/2026\/05\/399a4d95a67d409e804dd80bb6e79bbd-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Denn XLPPI:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Unterst\u00fctzt <strong>hei\u00df austauschbaren Modulen,<\/strong><\/p><\/li><li><p>optimiert <strong>Energieverbrauchs<\/strong><\/p><\/li><li><p>erh\u00e4lt <strong>die Signalintegrit\u00e4t<\/strong> bei h\u00f6heren Geschwindigkeiten<\/p><\/li><li><p>skaliert bis hin zu <strong>PAM4-\u00dcbertragung<\/strong> , wie sie f\u00fcr 200 G\/400 G\/800 G erforderlich ist<\/p><\/li><li><p>passt sich den mechanischen und elektrischen Randbedingungen der QSFP-Stecker an<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Alle modernen steckbaren Optikmodule \u2013<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\">SFP+<\/a>\/<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26225-25g-sfp28.htm\">SFP28<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\">QSFP+<\/a>\/<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491587.htm\">QSFP28<\/a>,<a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\"> QSFP56<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\">QSFP-DD<\/a>\u2013 verwenden <strong>von der MSA definierte Niederspannungsschnittstellen<\/strong>, darunter XLPPI.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Relevanz des Anwendungsfalls f\u00fcr LINK-PP-Kunden<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr Kunden, die Hochgeschwindigkeitsoptikmodule ausw\u00e4hlen <a target=\"_blank\" rel=\"\" href=\"https:\/\/l-p.com\"><strong>LINK-PP<\/strong><\/a>, wobei das Verst\u00e4ndnis von XLPPI und XLAUI folgende Punkte kl\u00e4rt:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Warum <strong>QSFP+- und QSFP28-Module auf XLPPI angewiesen sind<\/strong><\/p><\/li><li><p>Wie elektrische Schnittstellen <strong>die Interoperabilit\u00e4t von Modulen beeinflussen<\/strong><\/p><\/li><li><p>Welche Modultypen <strong>10G-, 25G-, 50G- oder 100G-Lane-Raten unterst\u00fctzen<\/strong><\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >XLPPI vs. XLAUI \u2013 \u00dcbersichtstabelle<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Kategorie<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/knowledge-center\/xlppi-electrical-interface-in-40g-qsfp-plus-modules-explained\/\"><strong>XLPPI<\/strong><\/a><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resourceslp.szlogic.cn\/de\/glossary\/xlaui-10-lane-attachment-unit-interface-ethernet-explained\/\"><strong>XLAUI<\/strong><\/a><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Standards<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MSA<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>IEEE<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Ethernet-Generationen<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>40G\u2013800G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Nur 40G<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Lane-Geschwindigkeiten<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10G \/ 25G \/ 50G \/ 100G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10G<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Modulation<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ &amp; PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Schnittstellenposition<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Host \u21c6 Steckbares Modul<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MAC \u21c6 PHY (intern)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Verwendet in<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/482754.htm\">QSFP+<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491587.htm\">QSFP28<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/473139.htm\">QSFP56<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\">QSFP-DD<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Internem Silizium<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p>Zuk\u00fcnftige Skalierbarkeit<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>High<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Keine<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >Abschlie\u00dfende Gedanken<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sowohl XLPPI als auch XLAUI sind kritische Komponenten der elektrischen Ethernet-Architektur, adressieren jedoch grundlegend unterschiedliche Anforderungen. <strong>XLPPI<\/strong> ist die Schnittstelle hinter modernen QSFP-Optiktransceivern und erm\u00f6glicht ein skalierbares, stromsparendes und hochdichtes Netzwerk von 40G bis 800G. <strong>XLAUI<\/strong>, bleibt hingegen eine wichtige IEEE-Schnittstelle innerhalb der internen Logik von 40G-Ethernet, wird jedoch nicht am Steckverbinder des modularen Transceivers verwendet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Das Verst\u00e4ndnis dieser Unterschiede hilft Netzwerk-Ingenieuren bei der Auswahl der richtigen Hardware \u2013 und unterst\u00fctzt Organisationen dabei, Stabilit\u00e4t und zukunftssichere Kompatibilit\u00e4t \u00fcber ihre gesamte optische Infrastruktur hinweg sicherzustellen.<\/p>","protected":false},"excerpt":{"rendered":"<p>Erfahren Sie die wichtigsten Unterschiede zwischen den elektrischen Schnittstellen XLPPI und XLAUI, wie sie in 40G-\/100G-Ethernet-Systemen funktionieren und welche Schnittstelle moderne QSFP-Module verwenden.<\/p>","protected":false},"author":1,"featured_media":3346,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[18,26],"class_list":["post-3347","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-40g-qsfp-transceivers","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3347","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/comments?post=3347"}],"version-history":[{"count":4,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3347\/revisions"}],"predecessor-version":[{"id":10781,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/posts\/3347\/revisions\/10781"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media\/3346"}],"wp:attachment":[{"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/media?parent=3347"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/categories?post=3347"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resourceslp.szlogic.cn\/de\/wp-json\/wp\/v2\/tags?post=3347"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}